steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 33555 |
| Manufacturer | Schneider |
| Product Name | ComPact NS800N Circuit Breaker |
| Range | ComPact NS |
| Device Type | Circuit Breaker |
| Application | Distribution |
| Number of Poles | 4P |
| Protected Poles Description | 4D |
| Neutral Position | Left |
| Rated Current | 800 A at 50 °C |
| Rated Operational Voltage | 690 V AC 50/60 Hz |
| Network Type | AC |
| Network Frequency | 50/60 Hz |
| Suitability for Isolation | Yes, conforming to EN/IEC 60947-2 |
| Utilisation Category | Category B |
| Rated Ultimate Short-Circuit Capacity | 30 kA at 660/690 V AC, 50 kA at 380/415 V AC, 50 kA at 440 V AC, 85 kA at 220/240 V AC, 40 kA at 500/525 V AC, conforming to IEC 60947-2 |
| Performance Level | N 50 kA 415 V AC |
| Trip Unit Name | Micrologic 5.0 |
| Trip Unit Technology | Electronic |
| Trip Unit Protection Functions | LSI (Long-time, Short-time, Instantaneous) |
| Control Type | Toggle Rotary Handle |
| Mounting Mode | Fixed |
| Rated Insulation Voltage | 800 V AC 50/60 Hz, conforming to IEC 60947-2 |
| Rated Impulse Withstand Voltage | 8 kV, conforming to IEC 60947-2 |
| Rated Service Short-Circuit Capacity | 30 kA at 660/690 V AC, 40 kA at 500/525 V AC, 50 kA at 220/240 V AC, 50 kA at 380/415 V AC, 50 kA at 440 V AC, conforming to IEC 60947-2 |
| Rated Short-Time Withstand Current | 19.2 kA for 1 second, conforming to IEC 60947-2 |
| Mechanical Durability | 10,000 cycles |
| Electrical Durability | 2,000 cycles at 690 V In, 4,000 cycles at 690 V In/2, 5,000 cycles at 440 V In, 6,000 cycles at 440 V In/2 |
| Power Losses | 15 W |
| Mounting Support | Backplate |
| Connection Type | Front (upside and downside) |
| Connection Pitch | 70 mm |
| Protection Type | L: Overload (long time), S: Short-time short-circuit, I: Instantaneous short-circuit |
| Trip Unit Rating | 800 A at 50 °C |
| Long-Time Protection Adjustment | Adjustable, 9 settings, 0.4...1 x In |
| Short-Time Protection Adjustment | Adjustable, 9 settings, 1.5...10 x Ir |
| Instantaneous Protection Adjustment | Adjustable, Off, 2...15 x In |
| Earth-Leakage Protection | Without |
| Neutral Protection Settings | No protection (3D), 0.5 x Ir (3D + N/2), 1 x Ir (4D) |
| Auxiliary Contact Composition | 1 NO/NC |
| Local Signalling | 4 LEDs (red) for fault indication, 1 LED (yellow) for overload |
| Dimensions (W x H x D) | 280 mm x 327 mm x 147 mm |
| Net Weight | 18 kg |
| Standards | EN/IEC 60947-2 |
| Product Certifications | ASEFA, ASTA |
| Pollution Degree | 3, conforming to IEC 60947 |
| IP Degree of Protection | IP40, conforming to IEC 60529 |
| IK Degree of Protection | IK07, conforming to EN 50102 |
| Ambient Air Temperature for Operation | -25…70 °C |
| Ambient Air Temperature for Storage | -50…85 °C |
| Relative Humidity | 0…95% |
| Operating Altitude | 0...2000 m without derating, 2000 m...5000 m with derating |
| Sustainable Offer Status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Compliant with Exemptions |
| Mercury Free | Yes |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile, Circularity Profile, End Of Life Information |
| WEEE | The product must be disposed of on European Union markets following specific waste collection and never end up in rubbish bins |
This is a circuit breaker designed for distribution applications.
The circuit breaker has a rated current capacity of 800 A at 50 °C.
This circuit breaker features 4 poles.
The rated operational voltage is 690 V AC at 50/60 Hz.
The rated ultimate short-circuit breaking capacity is 50 kA at 380/415 V AC.
It uses a Micrologic 5.0 electronic trip unit.
Yes, it is suitable for isolation conforming to EN/IEC 60947-2.
The dimensions are 280 mm in width, 327 mm in height, and 147 mm in depth.
The circuit breaker has an IP40 degree of protection.
The mechanical durability is rated at 10,000 cycles.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.