steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 33248 |
| Manufacturer | Schneider |
| Product Name | ComPact NS1000H Circuit Breaker |
| Range | ComPact NS |
| Device Application | Distribution |
| Number of Poles | 3P |
| Rated Current | 1000 A at 50 °C |
| Rated Operational Voltage | 690 V AC 50/60 Hz |
| Network Type | AC |
| Network Frequency | 50/60 Hz |
| Suitability for Isolation | Yes, conforming to EN/IEC 60947-2 |
| Utilisation Category | Category B |
| Rated Ultimate Short-Circuit Capacity | 70 kA at 380/415 V AC 50/60 Hz |
| Trip Unit Name | MicroLogic 2.0 A |
| Trip Unit Technology | Electronic |
| Trip Unit Protection Functions | LI (Long-time and Instantaneous) |
| Control Type | Rotary handle, Toggle |
| Circuit Breaker Mounting Mode | Fixed |
| Rated Insulation Voltage | 800 V AC 50/60 Hz |
| Rated Impulse Withstand Voltage | 8 kV |
| Rated Service Short-Circuit Capacity | 50 kA at 380/415 V AC 50/60 Hz |
| Rated Short-Time Withstand Current | 19.2 kA 1 s |
| Mechanical Durability | 10,000 cycles |
| Electrical Durability | 2,000 cycles at 690 V In, 4,000 cycles at 690 V In/2, 5,000 cycles at 440 V In, 6,000 cycles at 440 V In/2 |
| Power Losses | 22 W |
| Mounting Support | Backplate |
| Connection Type | Front (upside and downside) |
| Connection Pitch | 70 mm |
| Protection Type | L: for overload protection (long time), I: for instantaneous short-circuit protection |
| Long-Time Pick-Up Adjustment Type | Adjustable, 9 settings |
| Long-Time Protection Delay Adjustment | Adjustable, 9 settings |
| Instantaneous Protection Pick-Up | Adjustable, range 1.5...10 x Ir |
| Earth-Leakage Protection | Without |
| Zone Selective Interlocking | Without |
| Auxiliary Contact Composition | 1 NO/NC |
| Local Signalling | 4 LEDs (red) for fault indication, 1 LED (yellow) for overload |
| Display Type | LCD display |
| Type of Measurement | Ammeter |
| Dimensions (W x H x D) | 210 mm x 327 mm x 147 mm |
| Net Weight | 14 kg |
| Standards | EN/IEC 60947-2 |
| Product Certifications | ASTA, ASEFA |
| Pollution Degree | 3, conforming to IEC 60947 |
| IP Degree of Protection | IP40, conforming to IEC 60529 |
| IK Degree of Protection | IK07, conforming to EN 50102 |
| Ambient Air Temperature for Operation | -25…70 °C |
| Ambient Air Temperature for Storage | -40…85 °C |
| Relative Humidity | 0…95% |
| Operating Altitude | 0...2000 m without derating, 2000 m...5000 m with derating |
| Sustainable Offer Status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Compliant with Exemptions |
| Mercury Free | Yes |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile, Circularity Profile, End Of Life Information |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
The Schneider 33248 is a circuit breaker designed for distribution applications, providing protection against overloads and short circuits.
The circuit breaker has a rated current capacity of 1000 A at 50 °C.
This circuit breaker uses a Micrologic 2.0A electronic trip unit.
The Schneider 33248 circuit breaker is a 3-pole device.
The rated operational voltage for this circuit breaker is 690 V AC at 50/60 Hz.
Yes, the Schneider 33248 circuit breaker is suitable for isolation, conforming to EN/IEC 60947-2.
The mechanical durability of the Schneider 33248 circuit breaker is 10,000 cycles.
The circuit breaker has an IP40 degree of protection, conforming to IEC 60529.
The dimensions of the Schneider 33248 circuit breaker are 210 mm in width, 327 mm in height, and 147 mm in depth.
The operating temperature range for this circuit breaker is -25 to 70 °C.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.