steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | IFMA0035 |
| Manufacturer | Red Lion |
| Product Type | Frequency to Analog Converter |
| Mounting Type | DIN Rail Mount |
| Power Requirements | 9-32 VDC |
| Frequency Input Range | 0 Hz to 25 KHz; user selectable |
| Signal Input | DIP switch selectable for various sources |
| Signal Voltage Output | 0 to 5 VDC, 0 to 10 VDC; selectable |
| Signal Current Output | 0 to 20 mA, 4 to 20 mA; selectable |
| Output Compliance | Voltage: 10 V across min. 1KΩ load; Current: 20 mA through max. 500Ω load |
| Accuracy | ±0.1% of full scale range (±0.2% for 0 to 5 VDC range) |
| Response Time | 5 msec +1 period to 10 sec +1 period; user selectable |
| Input Impedance | 33 KΩ min. with sink and source DIP switches off |
| Isolation | 2200 V between power & input, and power & output; 500 V between input & output |
| Certifications and Compliances | UL Recognized Component, meets EN 50081-2 and EN 50082-2 standards |
| Environmental Conditions | Operating Temperature: 0 to 50°C, Storage Temperature: -40 to 80°C, Humidity: 85% max. |
| Construction | High impact plastic case, Installation Category II, Pollution Degree 2 |
| Weight | 6 oz. (0.17 Kg) |
To set the input frequency range, you need to access the configuration mode using the DIP switches on the device. Once in configuration mode, you can either apply the maximum input signal and use the push-button to capture the setting, or manually set the frequency using the rotary switch. Detailed steps for both methods are outlined in the device's manual.
Yes, the converter is designed with a programmable input circuit that can accept signals from a wide variety of sensors, including switch contacts, outputs from CMOS or TTL circuits, magnetic pickups, and standard sensors.
The converter can be powered by either an AC supply ranging from 85 to 250 VAC at 48 to 62 Hz or a DC supply from 9 to 32 VDC. It is important to ensure that the power supplied to the unit is within these specified limits for optimal performance.
The converter can output either a voltage signal (0 to 5 VDC, 0 to 10 VDC) or a current signal (0 to 20 mA, 4 to 20 mA), depending on the operating mode selected via the DIP switches.
The minimum and full scale output values can be adjusted using the calibration routines provided in the device's manual. You will need to connect a current or voltmeter to the output pins and use the rotary switch and push-button to adjust the values as required.
The output signal from the converter is accurate to ±0.1% of full scale for Operating Modes 2, 3, and 4. Operating Mode 1, which uses a 0 to 5 VDC range, is accurate to ±0.2% of full scale.
The converter has an output LED that indicates over-range by turning on and clamping the output at the maximum level. For low frequency cut-out conditions, the LED also turns on to indicate that the input frequency is below the zero frequency setting.
Yes, the converter features 3-way electrical isolation between power, input, and output to prevent signal interference and ensure the integrity of the output signal.
Absolutely, the converter is designed with a high degree of immunity to ElectroMagnetic Interference (EMI) and follows EMC guidelines, making it suitable for use in industrial environments.
The converter is designed to operate within a temperature range of 0 to 50°C and can be stored at temperatures from -40 to 80°C. It can also handle up to 85% humidity (non-condensing) from 0°C to 50°C and is suitable for altitudes up to 2000 meters.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.