steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 827265 |
| Manufacturer | Pilz |
| Voltage Monitoring Relay | To monitor minimum and maximum voltage values |
| Measuring Ranges | 12 ranges selectable, 0.1 - 500 V AC/DC |
| Frequency Range | 0.40 - 400 Hz |
| Width | 22.5 mm |
| Supply Voltage (UB) | 230 - 240 V AC |
| Measuring Inputs | Not polarity-sensitive |
| Supply Voltage Type U1 | AC |
| Power Consumption AC | 2 VA |
| Max. Device Circuit Breaker | Compatible with standard device circuit breakers |
| Relay Outputs | Utilisation categories AC/DC1, AC15/DC13 according to EN 60947-4-1 and EN 60947-5-1 standards |
| Safety Contacts | 240 VAC Resistive, NO Side Only |
| Safety Contacts Pilot Duty | B300, R300 |
| Relay Contact Material | AgCdO with additional contact details relay + 3.0 µm Au |
| Climatic Suitability | According to EN 60068-2-78 |
| Ambient Temperature Range | -15 - 55 °C |
| Condensation | Not permitted |
| EMC Standards | EN 60947-5-1, EN 61000-6-2 |
| Mounting Position | Any |
| Housing Material | Lower section: PPO UL 94 V0, Front plate: ABS UL 94 V0, Upper part: PPO UL 94 V0 |
| Connection Terminal | Screw terminal |
| Terminal Style | Fixed |
| Flexible Conductor Cross Section | 24 - 10 AWG |
| Dimensions (H x W x D) | 87 mm x 22.5 mm x 121 mm |
| Net Weight | 160 g |
| Gross Weight | 170 g |
| REACh Compliance | Contains minimum 1 SVHC-substance |
| WEEE Classification | 5 devices (feed size < 50cm) |
| ECLASS Version | ECLASS-9.1 |
| ETIM Version | ETIM-7.0 |
The voltage monitoring relay is designed to monitor minimum and maximum voltage values across a range of 0.1 to 500 V AC/DC, ensuring that the voltage stays within specified limits for safe and reliable operation of electrical equipment.
Yes, the measuring inputs of the relay are not polarity-sensitive, which allows for more flexibility in connecting the relay to various types of electrical circuits.
The relay has a height of 87 mm, a width of 22.5 mm, and a depth of 121 mm, making it compact and suitable for installation in space-constrained environments.
The relay features a robust construction with housing materials including PPO UL 94 V0 for the lower section and upper part, and ABS UL 94 V0 for the front plate.
The relay is designed to operate within an ambient temperature range of -15 to 55 degrees Celsius, ensuring reliable performance across a wide range of environmental conditions.
No, the relay is not permitted to be used in environments where condensation is present, as it could affect the relay's performance and longevity.
The relay is equipped with screw terminals that are fixed in place, providing a secure and reliable connection for conductors ranging from 24 to 10 AWG.
The relay conforms to EN 60068-2-6 for vibration resistance and EN 60947-1 for clearance and creepage distances, ensuring it meets industry standards for mechanical robustness.
When connected to an AC supply voltage, the relay has a power consumption of 2 VA, making it an energy-efficient choice for voltage monitoring applications.
Yes, the relay is REACh compliant, although it contains a minimum of one SVHC (Substance of Very High Concern) substance. It is also classified under WEEE for waste electrical and electronic equipment.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.