What is the application range of this electronic module?
The 312200 electronic module from Pilz is designed for failsafe applications.
How many digital inputs and test pulse outputs does this module have?
The Pilz 312200 module has 4 digital inputs and 2 test pulse outputs.
What is the protection type of the housing?
The housing of the Pilz 312200 module has an IP20 protection type.
Which base modules are permitted for use with this electronic module?
The 312200 module can be used with the following base modules: PSSu BP 1/12C, PSSu BP 1/12S, PSSu BP 1/8C, PSSu BP 1/8S, PSSu BP-C1 1/12C, and PSSu BP-C1 1/12S.
What are the dimensions of this electronic module?
The Pilz 312200 module has a width of 12.6 mm, a height of 76.0 mm, and a depth of 60.2 mm.
What is the operating temperature range for this module?
The ambient operating temperature range for the Pilz 312200 module is 0 - 60 °C.