steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Phoenix Contact |
| Part Number | 1507353 |
| Product Name | SAC-2P-M12MSB/0,5-910/M12FSB |
| Product Type | Pre-assembled PROFIBUS bus system cable |
| Overview | Shielded PROFIBUS cable assembly designed for reliable industrial fieldbus connections using M12 B-coded interfaces; supplied in a compact 0.5 m length with straight plug-to-socket terminations. |
| Network / Protocol | PROFIBUS (up to 12 Mbps) |
| Number of Positions (Contacts Wired) | 2 |
| Connector A | M12 male (plug), straight, B-coded (inverse) |
| Connector B | M12 female (socket), straight, B-coded (inverse) |
| Shielding | Overall shield: plastic-coated aluminium foil plus tinned copper braided shield (optical coverage approx. 85%) |
| Cable Length | 0.5 m |
| Cable Type / Abbreviation | PROFIBUS cable type 910 |
| Conductor Construction | 1x2xAWG24/19 |
| Conductor Cross-Section | 2 × 0.25 mm² |
| Wire Colours | Red and green |
| Outer Sheath Material | PUR (polyurethane), halogen-free |
| Outer Sheath Colour | Violet, RAL 4001 |
| Cable Outer Diameter | 7.8 mm ± 0.2 mm |
| Rated Current (at 40°C) | 4 A |
| Rated Voltage | 48 V AC / 60 V DC |
| Nominal Voltage (Cable) | 30 V |
| Insulation Resistance (Connector) | ≥ 100 MΩ |
| Insulation Resistance (Cable) | ≥ 5 GΩ·km |
| Conductor Resistance | ≤ 78.6 Ω/km |
| Characteristic Impedance | 150 Ω ± 10% (3 MHz … 20 MHz) |
| Capacitance | Nominal 30 pF/m |
| Attenuation | ≤ 0.049 dB/m (at 16 MHz) |
| Test Voltage | Core/Core: 1500 V (50 Hz, 1 min); Core/Shield: 1500 V (50 Hz, 1 min) |
| Degree of Protection | IP65 / IP67 |
| Ambient Temperature (Plug/Socket, Operation) | -25 °C … +90 °C |
| Cable Temperature (Operation) | Fixed installation: -40 °C … +80 °C; Flexible installation: -30 °C … +80 °C; Drag chain applications: ≤ +70 °C |
| Minimum Bending Radius | Fixed: 40 mm; Movable: 65 mm |
| Insertion/Withdrawal Cycles | ≥ 100 |
| Recommended M12 Tightening Torque | 0.4 Nm |
| Contact Material | CuSn (copper-tin alloy) |
| Contact Surface Finish | Nickel / gold |
| Sealing Material | NBR |
| Approvals / Conformity | UL Listed / cUL Listed / cULus Listed / EAC / EAC-RoHS |
| Country of Origin | Poland |
| GTIN (EAN) | 4017918900175 |
| Weight (per piece, typical) | 70.100 g |
| Customs Tariff Number | 85444290 |
It is a pre-assembled PROFIBUS DP bus system cable designed for connecting PROFIBUS devices that use M12 B-coded interfaces, helping maintain consistent cabling and shielding performance in industrial environments.
It has a straight M12 B-coded plug on one end and a straight M12 B-coded socket on the other end, both shielded.
The cable is 0.5 m long (factory pre-assembled).
Yes. It is specified for PROFIBUS (up to 12 Mbps), using a PROFIBUS cable type designed for typical segment lengths up to 100 m (subject to network design rules and device requirements).
The PROFIBUS pair uses pin 2 (green, A line) and pin 4 (red, B line), wired straight-through from plug to socket.
Rated current is 4 A (at 40°C). Rated voltage is typically stated as 48 V AC / 60 V DC for this assembly; UL listing data may reference up to 300 V depending on the approval context. Verify the required rating for the specific installation.
Yes, it is shielded. The cable uses a foil shield plus a tinned copper braided shield (high coverage), intended to support good noise immunity for industrial bus installations.
The nominal wave impedance is 150 Ω (typically ±10% over the stated frequency range), matching standard PROFIBUS cabling requirements.
When properly mated, the connection is rated to industrial sealing levels, commonly stated as IP65 and IP67, with documentation also referencing IP69K for the connector system.
For the connected plug/socket, the operating range is specified as -25°C to +90°C. For the cable itself, specifications commonly state down to -40°C (fixed installation) and down to -30°C (flexible installation), up to +80°C (and up to +70°C for drag chain applications).
The outer sheath is PUR (halogen-free) and violet (RAL 4001), which is commonly associated with PROFIBUS cabling identification.
It uses 2 x 0.25 mm² signal conductors (approximately AWG 24) with stranded construction suited to industrial movement requirements.
The cable specifications include bending cycle capability and minimum bending radii for flexible use. Typical values include a minimum bending radius of around 65 mm for movable installation and guidance for drag chain use (including a reduced maximum cable temperature in drag chain operation).
A typical tightening torque for the M12 connector coupling is 0.4 Nm. Using the correct torque helps achieve sealing performance and reduces the risk of loosening due to vibration.
PROFIBUS segments generally require termination at the ends of the segment. This cable itself is not a terminating resistor; termination must be provided by the network’s end devices or by a dedicated termination component, depending on the installation.
They are wired straight-through, with the PROFIBUS signal conductors maintained from plug to socket (pin 2 to pin 2 and pin 4 to pin 4). For reference, this matches the standard pin usage for M12 B-coded PROFIBUS.
Key identifiers include the violet PUR jacket (RAL 4001), M12 B-coded connectors on both ends, shielded construction, and the short 0.5 m assembly length. In some inventories it may be referenced as Phoenix Contact 1507353.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.