steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Phoenix Contact |
| Part Number | 0903026 |
| Model | EC-E1 4A |
| Product Type | Electronic circuit breaker |
| Product Description | Compact, single-channel electronic circuit breaker for selective protection of 24 V DC load circuits. Combines active current limitation with overload shutdown to isolate electrical faults and reduce their impact on the upstream power supply. |
| Nominal Current | 4 A |
| Rated Operating Voltage | 24 V DC |
| Operating Voltage Range | 18–32 V DC |
| Protection Functions | Electronic overload protection and short-circuit current limitation |
| Signal Contact | One normally open, potential-free contact for remote status indication |
| Typical Quiescent Current | 25 mA ±5 mA when switched on |
| Rated Surge Voltage | 0.5 kV |
| Integrated Protection Element | Built-in failsafe element; no additional backup fuse required |
| Mounting | 35 mm DIN rail |
| Connection Method | Screw terminals |
| Solid Conductor Cross-Section | 0.5–16 mm² |
| Flexible Conductor Cross-Section | 0.5–16 mm² |
| Flexible Conductor with Ferrule | 0.5–10 mm², with or without a plastic sleeve |
| Conductor Size Range | 20–6 AWG |
| Stripping Length | 10 mm |
| Terminal Screw Thread | M4 |
| Maximum Tightening Torque | 1.2 Nm |
| Width | 12.5 mm |
| Height | 83 mm |
| Depth | 80 mm |
| Height on NS 35/15 DIN Rail | 90.5 mm |
| Housing Protection Rating | IP20 |
| Operating Ambient Temperature | 0–50 °C, non-condensing |
| Pollution Degree | 2 |
| Housing Flammability Rating | UL 94 V-0 |
| Colour | Black |
| Installation Restrictions | For continuous operation in rows without convection cooling, loading must not exceed 80% of nominal current. Parallel connection of multiple circuit breakers is not permitted. |
| Country of Origin | Germany |
The EC-E1 4A is designed for selective protection of 24 V DC load circuits supplied by switched-mode power supplies. It combines active electronic current limitation with overload shutdown to help isolate a faulty circuit.
The nominal current is 4 A and the rated operating voltage is 24 V DC. The specified operating voltage range is 18–32 V DC.
Active electronic current limitation restricts fault current, while the electronic tripping characteristic enables short-circuit detection even along long cable runs. This helps reduce the effect of a faulty load circuit on the upstream power supply.
Yes. It includes one normally open, volt-free signal contact for remote indication, allowing its status to be incorporated into a monitoring circuit.
The breaker mounts onto a 35 mm DIN rail. Compatible rail profiles include NS 35/7.5 and NS 35/15.
The unit measures 12.5 mm wide, 83 mm high and 80 mm deep. The specified height is 83 mm on NS 35/7.5 rail and 90.5 mm on NS 35/15 rail.
The breaker uses screw connections with M4 screws. The specified conductor stripping length is 10 mm, and the maximum tightening torque is 1.2 Nm.
For single conductors, the terminals accept solid or flexible conductors from 0.5 to 16 mm², corresponding to the stated range of 20–6 AWG. Flexible conductors fitted with ferrules are accepted from 0.5 to 10 mm². Separate limits apply when connecting two conductors in one terminal.
The specified ambient operating temperature is 0°C to 50°C under non-condensing conditions.
The housing has an IP20 protection rating. It does not provide protection against water ingress.
The manufacturer's technical data states that a separate backup fuse is not required because the breaker incorporates an integrated failsafe element.
Yes. When breakers are mounted in rows without convection cooling, the manufacturer's installation instructions limit continuous loading to a maximum of 80% of the nominal device current because of thermal effects.
No. Parallel connection of multiple circuit breakers is expressly prohibited by the manufacturer's installation instructions.
Listed accessories include continuous plug-in bridges, 35 mm DIN rails, end clamps and terminal markers. These provide options for arranging, securing and identifying breakers within a control panel.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.