steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | NJ10-30GK-N |
| Alternative Part Number | NJ1030GKN |
| Manufacturer | Pepperl + Fuchs |
| Switching Element Function | NAMUR, Normally Closed (NC) |
| Rated Operating Distance | 10 mm |
| Installation | Flush |
| Output Polarity | NAMUR |
| Assured Operating Distance | 0 ... 8.1 mm |
| Reduction Factor rAl | 0.4 |
| Reduction Factor rCu | 0.3 |
| Reduction Factor r304 | 0.85 |
| Nominal Voltage | 8.2 V (Ri approx. 1 kΩ) |
| Switching Frequency | 0 ... 300 Hz |
| Current Consumption | Measuring plate not detected ≥ 3 mA, Measuring plate detected ≤ 1 mA |
| Ambient Temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Connection Type | Cable |
| Housing Material | PBT |
| Sensing Face Material | PBT |
| Degree of Protection | IP66 / IP68 |
| Cable Diameter | 6 mm ± 0.2 mm |
| Bending Radius | > 10 x cable diameter |
| Cable Material | PVC |
| Core Cross-Section | 0.75 mm² |
| Cable Length | 2 m (standard), available in other lengths |
| Compliance with Standards | EN 60947-5-2:2007, IEC 60947-5-2:2007, and amendments |
| Approvals and Certificates | IECEx, ATEX, EAC, FM, UL, CSA, CCC, NEPSI, Marine approval |
| Functional Safety | Usable up to SIL 2 according to IEC 61508 |
| MTTFd | 5070 years |
| Mission Time (TM) | 20 years |
| Diagnostic Coverage (DC) | 0% |
The inductive sensor can operate in ambient temperatures ranging from -25 to 100 °C (-13 to 212 °F).
Yes, the sensor is designed for flush mounting.
The rated operating distance for the sensor is 10 mm.
The sensor provides a NAMUR, normally closed (NC) output.
Yes, the sensor has certifications for use in hazardous areas, including ATEX, IECEx, and others, making it suitable for such environments.
The sensor's housing provides a degree of protection of IP66/IP68.
The housing material is PBT, and the sensing face is also made of PBT.
The reduction factor indicates the change in the sensor's operating distance when detecting metals other than standard mild steel, such as aluminium, copper, or 304 stainless steel.
The sensor comes with a PVC cable that has a diameter of 6 mm ± 0.2 mm, a bending radius greater than 10 times the cable diameter, and a core cross-section of 0.75 mm².
A mounting flange, specifically the BF 30 model, is recommended for use with this sensor for proper installation.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.