steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Pepperl + Fuchs |
| Part Number | KFU8-GUT-1.D |
| Alternative Part Number | KFU8GUT1D |
| Product Type | Temperature converter with trip values |
| Device Function | Universal input signal conditioner that converts RTD, thermocouple, potentiometer, or voltage signals into a proportional analog current output with relay trip outputs |
| Signal Type | Analog input |
| Number of Channels | 1-channel |
| Input Types | RTD, thermocouple, potentiometer, and voltage input |
| RTD Compatibility | Pt100, Pt500, Pt1000, Ni100, and Ni1000 |
| RTD Measuring Methods | 2-wire, 3-wire, and 4-wire technology |
| Thermocouple Compatibility | Types B, E, J, K, L, N, R, S, and T |
| Thermocouple Features | External or internal cold junction compensation with redundant thermocouple input capability |
| Potentiometer Input Range | 0.8 kΩ to 20 kΩ |
| Potentiometer Measuring Methods | 2-wire, 3-wire, and 5-wire technology |
| Voltage Input Ranges | 0 to 10 V, 2 to 10 V, 0 to 1 V, and -100 to 100 mV |
| Analog Output | 0 to 20 mA or 4 to 20 mA current output |
| Relay Outputs | 2 relay contact outputs |
| Relay Contact Rating | 250 V AC / 2 A or 40 V DC / 2 A |
| Output Load | Up to 650 Ω for analog current output |
| Fault Signal | Downscale current ≤ 3.6 mA or upscale current ≥ 21 mA according to NAMUR NE43 |
| Line Monitoring | Sensor breakage and sensor short-circuit monitoring, depending on input type |
| Sampling Rate | Approximately 700 ms |
| Supply Voltage | 20 to 90 V DC or 48 to 253 V AC |
| Power Consumption | Up to 2.2 W or 3 VA, depending on supply conditions |
| Electrical Isolation | Galvanic isolation between input, output, interface, and power supply circuits |
| Configuration | Configurable using the front keypad and integrated display interface |
| Display and Indicators | LC display with power, output, and fault indication LEDs |
| Connection Terminals | Removable terminal blocks |
| Mounting | 35 mm DIN rail mounting according to EN 60715 |
| Degree of Protection | IP20 |
| Ambient Temperature Range | -20 to 60 °C (-4 to 140 °F) |
| Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 in) |
| Housing Type | C3 housing |
| Approximate Mass | 300 g |
| Standards and Conformity | EN 61326-1, EN 61010-1, EN 50178, IEC 60529, and NE 21 conformity references |
| Suitable Applications | Industrial temperature and process signal conditioning where isolated measurement conversion, relay trip values, and analog output are required |
This is a 1-channel temperature converter with trip values. It acts as a signal conditioner, converting input signals from temperature sensors, potentiometers, or voltage sources into a proportional analog current output while also providing relay trip outputs.
The unit can accept RTD inputs such as Pt100, Pt500, Pt1000, Ni100, and Ni1000; thermocouple inputs including types B, E, J, K, L, N, R, S, and T; potentiometer inputs from 0.8 kΩ to 20 kΩ; and voltage inputs including 0 to 10 V, 2 to 10 V, 0 to 1 V, and -100 to 100 mV.
It provides two relay contact outputs and one analog current output. The current output can be configured for 0 to 20 mA or 4 to 20 mA operation, making it suitable for process monitoring and control applications.
The KFU8-GUT-1.D operates with a wide supply range of 20 to 90 V DC or 48 to 253 V AC, allowing it to be used in a variety of industrial control panel environments.
Yes. For thermocouple applications, a removable K-CJC terminal block can be used when internal cold junction compensation is required. External cold junction compensation is also specified for this unit.
Yes. The device includes measuring circuit monitoring features such as sensor breakage detection and, for RTD inputs, sensor short-circuit detection. It also provides line fault and sensor burnout detection functions.
The relay outputs are rated for 250 V AC at 2 A with a power factor of cos φ ≥ 0.7, or 40 V DC at 2 A. The mechanical relay life is specified as 50,000,000 switching cycles.
The unit is designed for mounting on a 35 mm DIN rail in accordance with EN 60715. Its dimensions are 40 x 119 x 115 mm, using a C3 housing style.
The specified ambient operating temperature range is -20 to 60 °C, or -4 to 140 °F.
The unit has an IP20 degree of protection, which is typical for components installed inside industrial electrical cabinets or protected control enclosures.
The analog current output has a maximum load of 650 Ω and an open-loop voltage of up to 24 V DC.
Yes. The device can accept a redundant thermocouple input of the same type. If one thermocouple lead break is detected, the value from the second thermocouple can be used for further calculation.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.