What type of cable assembly is this?
The 300755 is a single-ended female cordset, designated V15L-G-5M-PUR-U. It combines a straight, five-pin, L-coded M12 socket with a 5 m cable and an unterminated cable end.
What connector is required for a compatible connection?
The cordset requires a matching L-coded M12 male connector. Its female socket has five contacts and an M12 x 1 screw connection. Connector size alone does not establish compatibility; the coding and contact arrangement must also match.
How long is the cable, and what is its diameter?
The cable is 5 m long and has an outer sheath diameter of 8 mm.
What are the voltage and current limits?
The datasheet specifies a maximum operating voltage of 48 V AC or 63 V DC and a maximum operating current of 16 A. It separately lists a rated operating voltage of 600 V AC; this should not be interpreted as permission to exceed the stated operating-voltage limits. Temperature derating must also be observed.
How many conductors are included, and how are they identified?
There are five conductors, each with a cross-sectional area of 1.5 mm². The contact-to-core assignments are pin 1 brown, pin 2 white, pin 3 blue, pin 4 black and pin 5 pink.
What materials are used in the cable?
The cable has a grey polyurethane (PUR) outer sheath and polypropylene (PP) core insulation. The sheath colour is similar to RAL 7032. The cable is oil-resistant, and the assembly is specified as halogen-free and free from paint-wetting interfering substances.
What ingress protection ratings are specified?
The connector is specified with IP65, IP67 and IP69 protection ratings. The connection must be correctly assembled with a suitable mating connector to maintain the intended protection.
What temperature ranges apply to the connector and cable?
The connector is rated from −40 °C to +125 °C, subject to derating. The cable is rated from −40 °C to +90 °C when fixed and from −30 °C to +90 °C when flexing. Under the stated UL conditions, the cable's upper temperature limit is +80 °C for both fixed and flexing use.
Can the cable be used where movement occurs?
The datasheet provides limits for flexing use, including a minimum bend radius greater than 7.5 times the cable diameter. It does not specify a drag-chain rating or a flex-cycle endurance figure, so suitability for continuous repetitive movement should not be assumed.
What bend radius is required for a fixed installation?
For a fixed installation, the cable bend radius must be greater than four times its outer diameter. Allow sufficient space around the cable route to avoid tight bends near the connector.
What tightening torque and tool size are specified?
The connector's specified tightening torque is 0.6 Nm. Its coupling features straight knurling and a 14 mm hexagon for tool-assisted installation.
What materials are used in the connector?
The connector has a nickel-plated zinc die-cast screw coupling, a black TPE body and an FKM seal. The contact surface is specified as Cu/Au.
How many mating cycles is the connector rated for?
The connector is specified for a minimum of 100 mating cycles.
What UL information is listed?
The datasheet identifies the cordset as UL listed for the USA and Canada and gives UL file number E520151. The cable is specified as AWM Style 20939, with an 80 °C temperature rating, a 600 V rating and VW-1 flammability classification.