steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part number | 85441 |
| Manufacturer | Murr Elektronik |
| Series | Emparro |
| Model designation | Emparro 10-100-240/24 |
| Product type | Single-phase DIN rail power supply |
| Input voltage | 85...265 V AC or 90...250 V DC |
| Nominal input range | 100...240 V AC or 100...230 V DC |
| Input frequency | 50/60 Hz ±6% |
| Input current | 2.6 A at 100 V AC; 1.1 A at 240 V AC |
| Inrush current | Max. 13 A |
| Power factor | 0.95 |
| Output voltage | 24 V DC nominal |
| Adjustable output range | 24...28 V DC |
| Factory setting | 24.1 V DC ±0.2 V |
| Output current | 10 A |
| Output current at 28 V DC | 8.5 A up to +60°C; 10.2 A up to +45°C |
| Power Boost | 150% for minimum 4 seconds without voltage drop |
| Hyper Boost | 450% for minimum 20 ms at 60°C |
| Mains failure bridging time | Minimum 30 ms at 100 V AC with 10 A load at 24 V DC |
| Ripple | Max. 50 mV rms |
| Spikes | Max. 200 mV p-p |
| Efficiency | Up to 94.3% at 230 V AC; 92.8% at 110 V AC |
| Protection features | Short-circuit, overload and overtemperature protection |
| Housing protection | IP20 |
| Protection class | Class I |
| Electrical isolation level | SELV |
| Parallel connection | Yes, up to 5 units |
| Series connection | Yes, up to 2 units |
| Alarm contact | Potential-free alarm contact, terminals 13/14 |
| Alarm contact rating | Max. 30 V AC/DC, 50 mA, resistive load |
| Status indication | Bi-colour LED: green for output OK, red for alarm |
| Input connection | Spring clamp terminals |
| Output connection | Spring clamp terminals |
| Input terminal arrangement | 3-pole: PE, N, L |
| Output terminal arrangement | 4-pole: -, -, +, + |
| Alarm terminal arrangement | 2-pole: 13, 14 |
| Mounting method | Snap-on mounting for TH35 DIN rail to EN 60715 |
| Cooling method | Natural convection |
| Installation orientation | Horizontal rail mounting |
| Dimensions (H × W × D) | 123 × 65 × 138 mm |
| Weight | 0.85 kg |
| Operating temperature | -40°C to +60°C |
| Derating threshold | From +45°C |
| Storage temperature | -40°C to +80°C |
| Relative humidity | 5% to 95%, non-condensing |
| Climatic category | 3K3 |
| Pollution degree | 2 |
| Recommended external fuse | Max. 20 A (time-delay), building installation |
| Internal primary fuse | 6.3 A, time-delay |
| Recommended circuit breaker | C4 |
| EMC / compliance | EN 61204-3, EN 55011 Class B Group 1, EN 61000-3-2, EN 61000-3-3 |
| Additional compliance | EN 60204-1, SEMI F47 |
| Country of origin | Czech Republic |
| EAN | 4048879381499 |
This is a DIN-rail mounted single-phase industrial power supply designed to convert a wide AC or DC input into a stable 24 V DC output for panel-based automation and control applications.
It accepts a wide input range of 85 to 265 V AC at 50 to 60 Hz, or 90 to 250 V DC. This flexibility makes it suitable for use across many industrial power systems.
The unit provides a nominal 24 V DC output at 10 A. The output voltage is adjustable from 24 to 28 V DC, which can be useful where a small voltage increase is needed to compensate for cable losses or application requirements.
Yes. The output can be adjusted between 24 and 28 V DC using the onboard potentiometer. Factory setting is typically around 24.1 V DC.
At 24 V DC, it delivers 10 A continuously up to +60°C, and up to 12 A at temperatures up to +45°C. At 28 V DC, the available continuous current is lower, with up to 8.5 A at +60°C and up to 10.2 A at +45°C.
Yes. It includes a Power Boost function that can provide 150% of nominal output power for at least 4 seconds. It also offers a short Hyper Boost capability of up to 450% of nominal current for at least 20 ms at 60°C, which helps with demanding inrush conditions.
Yes. It is designed for TH35 DIN-rail mounting in accordance with EN 60715. For proper convection cooling, it should be mounted with the rail in a horizontal orientation.
The housing measures 123 mm high, 65 mm wide and 138 mm deep, with a weight of approximately 0.85 kg. This compact format helps when panel space is limited.
Yes. It is intended for installation inside a control cabinet or enclosure, where natural convection can be maintained around the device.
The operating temperature range is -40°C to +60°C. Derating begins from +45°C. Storage temperature range is -40°C to +80°C according to the product datasheet, with some operating instruction versions listing storage up to +85°C.
The power supply includes output overload protection and short-circuit protection. It also has temperature-related protective behaviour to help prevent damage if ventilation is restricted or load conditions become excessive.
Yes. It features a bi-colour LED for output status indication and a potential-free alarm contact. When output voltage is OK, the contact is closed and the LED shows green; in alarm condition, the contact opens and the LED shows red.
Yes. Up to 5 units can be connected in parallel, provided their open-circuit voltages are set equally and the secondary cabling is matched. Up to 2 units can be connected in series while maintaining SELV output limits.
Efficiency is up to 94.3% at 230 V AC and approximately 92.8% at 110 V AC. High efficiency can help reduce heat build-up inside the panel.
The housing is rated IP20. This means it is intended for use inside an enclosure rather than in exposed environments.
The unit uses spring clamp terminals for input, output and alarm connections. This allows secure wiring for typical industrial cabinet installations.
Yes. 85441 is intended for applications that need a regulated 24 V DC supply, such as PLC systems, I/O modules, sensors, relays and other industrial control equipment within a cabinet environment.
Yes. In addition to standard AC input operation, the unit can also be operated from a DC input source within the specified range, which adds flexibility in certain system designs.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.