steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | A68P |
| Alternative Part Number | A68P |
| Manufacturer | Mitsubishi |
| Type | Extension Base Unit |
| Applicable Modules | A Series Module |
| Number of I/O Modules Connected | 8 |
| 5VDC Internal Current Consumption | 0.117 A |
| Weight | 2.00 kg |
| Dimensions (W x D x H) | 466 x 250 x 46.6 mm (Approximate dimensions for QA68B variant) |
| Installation | Mountable on flat surface, with specific clearances for heat dissipation and radiation noise |
| Expansion Cable Connector | Provided for signal transmission with basic base module or other expansion base modules |
| Module Fixing Hole | For securing module projections and hooks |
| Base Module Installation Hole | For mounting the base module to a panel such as a control panel |
| Stage Number Setting Connector | Used to set the stage numbers of the expansion base modules |
| Operating Temperature Range | Refer to the Mitsubishi general specifications for the applicable temperature range |
| Compatibility | Compatible with various Mitsubishi A Series modules including power, I/O, and special function |
The extension base unit is designed to connect with a variety of A series modules, including I/O modules, power supply modules, and special function modules. It's important to refer to the specific product documentation for a complete list of compatible modules.
The A68P extension base unit can support the connection of up to 8 I/O modules, providing a flexible and expandable solution for various industrial applications.
While the A68P is designed for general industrial use, it should not be used in applications where a failure could lead to serious accidents or in environments that require special quality assurance or fail-safe features beyond the general specifications of the product.
The unit requires a 5VDC power supply, with an internal current consumption of 0.117A. It's essential to ensure that the power supply module used with the unit meets these requirements for proper operation.
The unit should be installed in a position that allows for adequate ventilation to prevent overheating. It's recommended to maintain a certain distance from other heat-generating devices and ensure that there is enough space for air circulation around the unit.
Care should be taken not to drop or apply strong impacts to the modules during installation. Ensure that the module fixing projections are properly inserted into the module fixing holes, and that the module is securely fastened to prevent malfunctions.
The stage number for the A68P is set using the stage number setting connector located between the expansion cable connectors. The stage number should be set in ascending order, starting from 1, based on the position of the unit in relation to the main base unit.
When mounting the unit in a control panel, ensure that the surface is flat to avoid straining the PC board, which could lead to malfunctions. Also, consider the proximity to vibration sources and maintain the recommended distances from devices that could cause radiation noise or heat interference.
The unit should be operated in environments that do not exceed the general industrial conditions specified by the manufacturer. Avoid exposure to extreme temperatures, humidity, dust, corrosive gases, and direct sunlight.
To increase system reliability, it's advisable to implement backup and fail-safe functions outside of the unit. This ensures that any faults or failures within the unit do not lead to major system breakdowns or accidents.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.