steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Beckhoff |
| Part Number | KS2602 |
| Product Type | Bus Terminal with pluggable wiring |
| Function | Two-channel relay output terminal for switching mains-powered loads |
| Number of Outputs | 2 |
| Contact Type | 2 × normally open relay contacts connected to the power contacts |
| Rated Load Voltage | 230 V AC / 30 V DC |
| Supported Load Types | Resistive, inductive and lamp loads |
| Maximum Output Current | 5 A per channel |
| Resistive Switching Current | 5 A AC/DC |
| Inductive Switching Current | 2 A AC/DC |
| Minimum Permitted Load | 10 mA at 5 V DC |
| Lamp and Electronic Ballast Rating | Up to 5 A starting current; suitable for 4 × 58 W |
| Electrical Isolation | 500 V RMS between K-bus and field potential |
| K-bus Current Consumption | Typically 80 mA |
| Process Image Width | 2 output bits |
| Mechanical Operating Life | Minimum 20 million operations |
| Electrical Operating Life | Minimum 100,000 operations at 5 A and 30 V DC |
| Status Indication | Individual signal LED for each output |
| Configuration | No address or configuration settings required |
| Special Feature | Power relay outputs linked to the terminal’s power contacts |
| Approximate Weight | 85 g |
| Operating Temperature | 0 to +55 °C |
| Storage Temperature | −25 to +85 °C |
| Relative Humidity | Up to 95%, non-condensing |
| Vibration Resistance | Conforms to EN 60068-2-6 |
| Shock Resistance | Conforms to EN 60068-2-27 and EN 60068-2-29 |
| EMC Immunity | Conforms to EN 61000-6-2 |
| EMC Emissions | Conforms to EN 61000-6-4 |
| Protection Rating | IP20 |
| Installation Position | Variable |
The KS2602 is a two-channel relay output Bus Terminal designed to switch electrical loads within a Beckhoff automation system.
It provides two relay outputs, each configured as a normally open make contact connected to the power contacts.
The terminal is rated for loads up to 230 V AC or 30 V DC.
It can switch resistive, inductive and lamp loads, subject to the specified voltage and current limits.
Each channel can switch up to 5 A for resistive AC or DC loads. For inductive loads, the specified switching current is up to 2 A AC or DC.
The minimum permitted load is 10 mA at 5 V DC.
No. On the KS2602, the relay contacts are connected to the terminal's power contacts. Applications requiring potential-free contacts should use a suitably specified alternative.
Yes. A signal LED is provided for each output channel, allowing the switching state to be identified locally.
Typical K-bus current consumption is 80 mA.
It occupies two output bits in the process image, with one bit assigned to each relay channel.
No address or configuration setting is required for the terminal itself.
It provides 500 V RMS electrical isolation between the K-bus and the field potential.
The minimum mechanical operating life is 20 million cycles. The minimum electrical operating life is 100,000 cycles at a load of 5 A and 30 V DC.
The operating temperature range is 0 to +55 °C, while the storage temperature range is -25 to +85 °C.
The terminal is specified for relative humidity up to 95%, provided that condensation does not occur.
The terminal has an IP20 protection rating and is intended for installation within a suitable control enclosure.
Yes. The specified installation position is variable, allowing flexibility when arranging the terminal assembly.
The terminal weighs approximately 85 g.
Yes. As a KS-series Bus Terminal, it uses pluggable wiring to simplify connection and terminal replacement within the assembly.
Yes. Its relay outputs can control suitable mains-powered devices operating at up to 230 V AC, provided the connected load remains within the applicable switching ratings.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.