steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
It is a high-voltage ACOPOSmulti power supply module that converts three-phase AC mains into a DC bus for the drive system and can also handle regenerated energy back toward the supply. It is designed to act as the central power interface for the DC bus.
It supports TT, TN-S, and TN-C-S power systems and accepts a wide mains input range of 3 x 220 to 3 x 480 VAC (±10%) at 50/60 Hz (±4%).
The module uses a nominal 750 VDC bus. The internal DC bus capacitance is 825 µF, and the maximum allowable external DC bus capacitance depends on the mains voltage (e.g., 5.8 mF at 400 VAC).
Yes. It is capable of power regeneration and includes power factor correction (PFC). In operation, it can supply energy to the DC bus and also manage regenerated energy from connected axes.
For typical sizing, use up to 30 kW continuous power (supply and regeneration) and up to 60 kW peak power (supply and regeneration). The maximum installed load is specified as 31.1 kW.
No. It does not include an integrated line filter (per EN 61800-3 category C3) and it does not include an integrated regeneration choke. These are typically considered as associated external components in the overall system design.
It supports cold plate mounting or feed-through mounting. The module is designed for these mounting approaches to manage thermal performance appropriately within an ACOPOSmulti cabinet layout.
Permissible orientations include hanging vertically, hanging horizontally, and lying horizontally. Standing horizontally is not permissible.
The module is approximately 106.5 mm wide, 317 mm high, and about 212 mm deep for cold plate mounting (about 209 mm for feed-through mounting). Weight is approximately 4.5 kg. It occupies 2 module width units.
The nominal switching frequency is 5 kHz. A 10 kHz switching frequency is also possible, but it can require derating of continuous power and can increase losses compared to nominal operation.
It includes a 24 VDC input for internal supply and provides two 24 VDC outputs. The 24 V outputs are regulated based on DC bus voltage, include electronic auto-reset fuse protection (250 mA slow-blow characteristic), and are intended for low-power auxiliary loads.
It provides two trigger inputs with sink wiring. Typical input current at nominal 24 VDC is approximately 10 mA, with switching thresholds below 5 V (low) and above 15 V (high). The inputs are electrically isolated from the power supply module.
Key connectors include X1 (temperature sensor and DC bus ready signal), X2 (trigger inputs and 24 V outputs), X3A/X3B (network interface pinout), X4A (temperature sensor and fan connections for the power system), and X5A (three-phase mains input and protective earth).
The CR_OK (DC bus ready) output is set when the charging relay is closed and the DC bus voltage is above 270 VDC. This provides a simple readiness indication for sequencing within a control cabinet.
Nominal operating temperature range is 5 to 40°C, with operation up to 55°C possible with derating considerations. Permissible relative humidity during operation is 5 to 85%. Installation elevation is nominally 0 to 500 m, with operation up to 4000 m possible with specified reductions.
The module is rated IP20 and is specified for pollution degree 2 (non-conductive pollution) and overvoltage category III per EN 61800-5-1.
Yes. It has 2 slots for ACOPOSmulti plug-in modules, commonly used for feedback interfaces (e.g., EnDat, resolver, incremental encoders) or additional I/O interface options depending on the application needs.
It is specified with CE and KC compliance and includes UL/cULus listing (E225616) as power conversion equipment.
Maximum inrush current at 400 VAC is specified as 67 A, and a switch-on interval greater than 300 seconds is specified at the maximum loadable DC bus capacitance. These values help define upstream protection and sequencing expectations.
A dedicated terminal block set is specified as the required accessory for wiring. For reference, the associated set is commonly listed as 8BZVP044000.000-1A for the 8BVP0440HC00.000-1.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.