steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | ABB |
| Part number | KXT5CUAL2X500K-3PC |
| Alternative part number | kxt5cual2x500k3pc |
| Product type | Circuit breaker lug kit |
| Series compatibility | Designed for ABB Tmax XT5 circuit breaker applications |
| Pole configuration | 3-pole configuration |
| Conductor compatibility | Suitable for copper and aluminum conductors |
| Terminal arrangement | Dual-conductor lug arrangement |
| Conductor size range | Accepts 2 conductors per pole, from #2/0 AWG to 500 kcmil |
| Typical breaker application range | Listed by ABB for XT5 breaker applications in the 250 A to 600 A range, depending on the associated assembly |
| Typical use | Used to provide field termination points between the breaker and incoming or outgoing power conductors |
| Installation note | Commonly specified as a line/load lug option for XT5 enclosed breaker assemblies; application limits can vary with the enclosure and breaker combination |
This component is a breaker lug kit used to terminate incoming and outgoing power conductors on compatible XT5 circuit breaker assemblies. It is typically selected when a breaker needs field-installed line and/or load lugs rather than a fixed terminal arrangement.
For the lug itself, the listed conductor capacity is two conductors per pole in the range of #2/0 AWG to 500 kcmil, for copper or aluminum conductors where the connected equipment is marked for Cu-Al use. In some enclosed breaker applications, enclosure limitations can reduce the usable maximum conductor size.
It is intended for copper or aluminum conductors when the breaker and lug markings permit Cu-Al termination. The associated enclosure drawings also specify the use of 75°C conductors.
This version is intended for 3-pole applications. A separate 4-pole version is listed alongside it in the enclosure documentation, which helps distinguish this configuration from the 4-pole option.
This lug arrangement is designed for dual-conductor termination, allowing two conductors per pole within the stated wire range. That makes it useful in installations where parallel or paired conductors are required at the breaker connection point.
If lugs are required on both ends of the breaker, the documentation states that one kit is ordered for the line end and one kit is ordered for the load end. In other words, a single breaker may require two kits when both sides need lug terminations.
Yes. KXT5CUAL2X500K-3PC is listed in documentation for several XT5 enclosed breaker arrangements, including indoor Type 1, rainproof Type 3R, and other enclosure variants. Suitability still depends on the exact enclosure rating and available conductor space.
Not in every enclosure configuration. While the lug catalog data lists a range up to 500 kcmil, some 400A enclosure documents limit the practical wire size to 250 MCM CuAl. For that reason, the breaker lug range and the enclosure wire-space limit should be checked together.
No. This is a circuit breaker lug kit for the breaker terminals. Neutral assemblies and ground kits are listed separately in the same documentation and serve different functions within the enclosed breaker assembly.
The main points to confirm are breaker pole count, breaker frame/application, conductor material, conductor size, whether one or both ends of the breaker need lugs, and whether the breaker is installed in an enclosure that imposes a lower wire-size limit. These checks help confirm that the selected lug kit matches the physical and electrical requirements of the installation.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.