steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | ABB |
| Part Number | 2CCF019607R0001 |
| Model | S802PV-SP100 |
| Product Type | High-performance miniature circuit breaker for photovoltaic DC installations |
| Description | Two-pole, current-limiting circuit breaker designed for photovoltaic circuits, combining thermal overload protection with electromechanical short-circuit protection. |
| Number of Poles | 2 |
| Number of Protected Poles | 2 |
| Rated Current | 100 A |
| Tripping Characteristic | B |
| Rated Operational Voltage | 800 V DC |
| Rated Insulation Voltage | 1,500 V |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | 5 kA at 800 V DC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | 5 kA at 800 V DC |
| Rated Impulse Withstand Voltage | 8 kV |
| Energy Limiting Class | 3 |
| Overvoltage Category | III |
| Pollution Degree | 2 |
| Degree of Protection | IP20 |
| Terminal Type | Cage terminals |
| Rigid Conductor Capacity | Up to 50 mm² |
| Flexible Conductor Capacity | Up to 70 mm² |
| Power Loss | 16 W total; 8 W per pole at rated operating conditions |
| Operating Ambient Temperature | −25 to +60 °C |
| Width | 54 mm |
| Height | 95 mm |
| Depth | 82.5 mm |
| Net Weight | 490 g |
| Applicable Standard | IEC/EN 60947-2 |
| RoHS Status | Compliant with EU Directive 2011/65/EU |
| EAN | 7612271471392 |
The S802PV-SP100 is a two-pole, high-performance miniature circuit breaker designed for photovoltaic DC applications. It combines overload and short-circuit protection in a current-limiting device.
The rated current is 100 A. Selection should also take account of the circuit design, conductor ratings and operating conditions.
The circuit breaker is rated for operation at up to 800 V DC. This operating rating should not be confused with its higher insulation voltage rating.
The rated ultimate and service short-circuit breaking capacities are both 5 kA at 800 V DC. The prospective short-circuit current at the installation point must be considered when selecting the breaker.
The breaker has two poles, both of which are protected. It is designed for use in photovoltaic DC circuits.
A thermal tripping mechanism provides overload protection, while an electromechanical tripping mechanism responds to short circuits. The breaker has a B tripping characteristic.
The S802PV-SP100 complies with IEC/EN 60947-2, the standard covering low-voltage circuit breakers. Its documented compliance allows use in industrial applications.
It uses cage terminals. The stated connecting capacities are up to 50 mm² for rigid conductors and up to 70 mm² for flexible conductors.
The breaker measures 54 mm wide, 95 mm high and 82.5 mm deep. Its net weight is 490 g.
The specified ambient air temperature range during operation is −25 °C to +60 °C.
The breaker has an IP20 degree of protection. This provides protection against access with a finger but does not provide protection against water.
ABB 2CCF019607R0001 is intended for photovoltaic DC installations requiring a two-pole, 100 A circuit breaker. Its suitability for a particular circuit depends on the operating voltage, prospective fault current and installation requirements.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.