What type of application is this relay designed for?
This device is designed as an evaluation unit for machinery protection systems using safety sensors with OSSD outputs. It helps process signals from compatible protective devices and provides safe enabling contacts for machine control circuits.
Which sensor output types are compatible with this relay?
It is intended for use with safety sensors that provide OSSD outputs. It has two safety inputs and monitors the signal sequence from connected devices.
What supply voltage does this device require?
The relay operates from a 24 V DC supply, with an allowable range of 16.8 V DC to 30 V DC. The supply should be PELV or SELV.
How many safe output contacts does it provide?
The RLY3-OSSD300 provides three enabling current paths with positively guided normally open contacts for integration into machine control circuits.
What is the switching capacity of the enabling contacts?
The enabling contacts can switch 10 mA to 6 A, with switching voltages from 10 V AC to 230 V AC or 10 V DC to 230 V DC. The total current rating is 12 A.
Does this relay include diagnostic outputs?
Yes. It includes two application diagnostic outputs. These are push-pull semiconductor outputs and are not intended to be used as safe outputs.
What reset options are available?
The device supports restart interlock functionality and can be configured for automatic or manual reset, depending on how the external circuit is wired.
Does it support external device monitoring?
Yes. It includes an input that can be used for either a reset pushbutton or external device monitoring, often referred to as EDM.
What safety performance ratings are specified for this relay?
The relay is rated up to SIL 3 according to IEC 61508, Category 4 and PL e according to ISO 13849-1, with a PFHD value of 1.0 x 10^-9.
What is the response time of the enabling contacts?
The specified response time for opening the enabling current paths is 12 ms.
What are the physical dimensions of the unit?
The device measures 18 mm wide, 124.6 mm high and 85.5 mm deep. Its weight is approximately 150 g.
What environmental conditions is it designed to operate in?
It is designed for operation from -25 °C to +55 °C, with storage from -25 °C to +70 °C. The enclosure rating is IP20, and permissible humidity is up to 95% non-condensing.