| Manufacturer |
Schneider Electric |
| Part Number |
LC1D18JD |
| Series / Range |
TeSys Deca (LC1D) |
| Product Type |
IEC power contactor (non-reversing), open type with front protective cover |
| Typical Use |
Switching and control of three-phase motors and resistive loads in industrial control panels |
| Poles |
3-pole (3P) |
| Main Contact Configuration |
3 x Normally Open (3 NO) |
| Rated Operational Voltage (Ue) – Power Circuit |
Up to 690 V AC (25…400 Hz); up to 300 V DC |
| Rated Operational Current (Ie) – AC-3 |
18 A (≤ 440 V AC, at 60 °C ambient) |
| Rated Operational Current (Ie) – AC-3e |
18 A (≤ 440 V AC, at 60 °C ambient) |
| Rated Operational Current (Ie) – AC-1 |
32 A (≤ 440 V AC, at 60 °C ambient) |
| Motor Power (AC-3) |
4 kW (220…230 V), 7.5 kW (380…400 V), 9 kW (415…440 V), 10 kW (500 V), 10 kW (660…690 V) |
| Motor Power (AC-4) |
4 kW (400 V) |
| Maximum Horsepower Rating |
1 hp (115 V 1φ), 3 hp (230/240 V 1φ), 5 hp (200/208 V 3φ), 5 hp (230/240 V 3φ), 10 hp (460/480 V 3φ), 15 hp (575/600 V 3φ) |
| Control Circuit Type |
DC (standard) |
| Coil Voltage (Uc) |
12 V DC |
| Coil Technology |
Integral suppression device fitted |
| Control Voltage Limits (DC) |
Drop-out: 0.1…0.25 Uc; Operational: 0.7…1.25 Uc (−40…60 °C), 1…1.25 Uc (60…70 °C) |
| Inrush / Hold Power (at 20 °C) |
5.4 W inrush; 5.4 W hold |
| Operating Time |
Closing: 53.55…72.45 ms; Opening: 16…24 ms |
| Time Constant |
28 ms |
| Maximum Operating Rate |
3600 cycles/hour (at 60 °C) |
| Auxiliary Contacts |
1 NO + 1 NC (mechanically linked); mirror contact function on 1 NC (per IEC 60947-4-1) |
| Minimum Switching Voltage (Signalling) |
17 V |
| Minimum Switching Current (Signalling) |
5 mA |
| Signalling Circuit Frequency |
25…400 Hz |
| Non-overlap Time (Auxiliary) |
1.5 ms on energisation; 1.5 ms on de-energisation |
| Insulation Resistance (Signalling) |
> 10 MΩ |
| Rated Insulation Voltage (Ui) |
Power circuit: 690 V (IEC), 600 V (UL/CSA); Signalling circuit: 690 V (IEC), 600 V (UL/CSA) |
| Rated Impulse Withstand (Uimp) |
6 kV |
| Overvoltage Category |
III |
| Pollution Degree |
3 |
| Conventional Free-air Thermal Current (Ith) |
Power circuit: 32 A (60 °C); Signalling circuit: 10 A (60 °C) |
| Rated Making Capacity (Irms) |
Power circuit: 300 A at 440 V; Signalling: 140 A AC, 250 A DC |
| Rated Breaking Capacity |
300 A at 440 V (power circuit) |
| Short-time Withstand Current (Icw) |
Power: 145 A (10 s), 240 A (1 s), 84 A (1 min), 40 A (10 min) at 40 °C; Signalling: 100 A (1 s), 120 A (500 ms), 140 A (100 ms) |
| Associated Fuse Rating |
Signalling: 10 A gG; Power: 50 A gG (Type 1), 35 A gG (Type 2) up to 690 V |
| Average Impedance |
2.5 mΩ (power circuit, Ith 32 A, 50 Hz) |
| Power Dissipation per Pole |
2.5 W (AC-1); 0.8 W (AC-3 / AC-3e) |
| Mechanical Durability |
30 million cycles |
| Electrical Durability |
1.65 million cycles (18 A AC-3 / AC-3e ≤ 440 V); 1 million cycles (32 A AC-1 ≤ 440 V) |
| Mounting |
DIN rail or plate mounting |
| Terminals |
Screw clamp terminals (power and control) |
| Control Wiring Capacity |
Flexible or solid: 1…4 mm² (with/without cable end); certain flexible with ferrule up to 2.5 mm² (per terminal arrangement) |
| Power Wiring Capacity |
Flexible or solid: 1.5…6 mm² (without cable end); flexible with ferrule typically 1…6 mm² (terminal dependent) |
| Tightening Torque |
1.7 N·m (power and control screw clamp terminals) |
| IP Rating |
IP20 (front face) |
| Protective Treatment |
TH (damp heat resistant design) |
| Permissible Ambient Temperature (Operation) |
−40…60 °C; 60…70 °C with derating |
| Ambient Temperature (Storage) |
−60…80 °C |
| Operating Altitude |
0…3000 m |
| Fire Resistance |
850 °C (per IEC test method) |
| Flammability Rating |
V1 (UL 94) |
| Dimensions (H × W × D) |
77 mm × 45 mm × 95 mm |
| Net Weight |
0.49 kg |
| Standards |
IEC 60947-4-1, IEC 60947-5-1, EN 60947-4-1, EN 60947-5-1, UL 508, CSA C22.2 No 14, IEC 60335-1 |