What are the main features of the Flexi Classic safety controller?
The Flexi Classic safety controller offers potential-free make contacts with forced guidance, switchable voltage from 5 V AC/DC to 253 V AC/DC, and a current load capacity per OSSD of 10 mA to 6 A. It also includes notification and feedback current paths, with a compact design suitable for various safety applications.
Can the Flexi Classic safety controller operate in extreme temperatures?
Yes, the Flexi Classic safety controller is designed to operate within a temperature range of -25 °C to +55 °C, making it suitable for use in a variety of environmental conditions.
What type of outputs does the Flexi Classic safety controller provide?
The Flexi Classic safety controller provides potential-free make contacts for release current paths and potential-free break contacts for feedback current paths, both with forced guidance. It also offers make contacts on internal 24 V DC for notification current paths, with current limited output.
What is the protection class of the Flexi Classic safety controller?
The Flexi Classic safety controller has an IP40 protection class for the housing and IP20 for the terminals, ensuring a degree of protection against solid objects and a level of safety for the electrical components inside.
How does the Flexi Classic safety controller handle electromagnetic compatibility?
The Flexi Classic safety controller is classified as Class A in terms of electromagnetic compatibility (EMC), complying with EN 61000-6-2 and EN 55011 standards, which means it is suitable for industrial environments with a controlled level of EMC emissions.
What are the dimensions and weight of the Flexi Classic safety controller?
The Flexi Classic safety controller measures 22.5 mm in width, 96.5 mm in height, and 120.8 mm in depth, with an approximate weight of 186 g (± 5%).
How is the Flexi Classic safety controller classified according to eCl@ss standards?
The Flexi Classic safety controller is classified under eCl@ss standards from 5.0 up to 12.0, with the code 27243101, ensuring it meets the international data standard for the classification and description of products and services.
What kind of vibration resistance does the Flexi Classic safety controller have?
The Flexi Classic safety controller is designed to withstand vibrations of 5 g RMS in the frequency range of 5 Hz to 500 Hz, as per EN 60068-2-64, making it robust for use in environments with varying degrees of vibration.