Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | IC695ALG600 |
| Manufacturer | GE Fanuc |
| Product Family | PACSystems RX3i |
| Product Category | PLC Systems |
| Module Type | Universal analogue input module |
| Supported Input Types | Voltage, current, resistance, RTD and thermocouple inputs |
| System Format | Chassis-based, rack-mounted modular I/O |
| Module Installation | Pluggable RX3i I/O module |
| Hot-Swap Capability | Yes |
| Terminal Block Type | Removable terminal block |
| Compatible Accessory | IC695ACC600 cold-junction compensation kit |
| Typical Applications | Process control, complex machine control, motion control and general industrial automation |
The IC695ALG600 is a universal analogue input module designed for PACSystems RX3i PLC installations. It converts signals from field instruments and sensors into data that can be processed by the controller.
It can accept voltage, current, resistance, resistance temperature detector (RTD) and thermocouple inputs. This flexibility allows one module type to handle several common industrial measurement applications.
A universal module can be configured for different signal and sensor types rather than being limited to a single measurement format. This can simplify system design and reduce the number of specialised input modules required in a control cabinet.
The module belongs to the PACSystems RX3i family and is intended for installation in a compatible RX3i rack-based control system.
Typical uses include monitoring temperature, pressure, flow, level, resistance and other process variables in manufacturing, process control, machine control and general automation installations.
Yes. The module accepts thermocouple inputs for industrial temperature measurement. The selected thermocouple type and channel settings must match the connected sensor.
Yes. RTD input capability allows the module to measure temperature through compatible resistance-based sensors. Wiring and configuration should be selected according to the RTD type used in the installation.
Yes. The IC695ACC600 cold-junction compensation kit is the associated RX3i accessory for thermocouple measurements made with the IC695ALG600.
RX3i I/O modules use removable terminal blocks, helping make initial wiring, module replacement and cabinet maintenance more manageable. The terminal block must be compatible with the module and the installation requirements.
Yes. The RX3i I/O platform provides hot-swap capability. Any module change should still follow the approved site procedure and the system's operating requirements.
It is a rack-mounted I/O module that plugs into a compatible PACSystems RX3i backplane. The rack must have a suitable slot, power capacity and system configuration.
Standard RX3i I/O is generally specified for IP20 installations and an operating range of 0°C to 60°C. Low-temperature and conformal-coated variants exist for selected RX3i products, but the exact suffix and rating should be checked before substitution.
Potentially, provided the required signal types, channel arrangement, electrical characteristics and system configuration are compatible. A universal module can consolidate several measurement types, but it should not be treated as a direct replacement without checking the application requirements.
Check the rack and slot compatibility, terminal block type, field wiring, configured input ranges, sensor types, power requirements and channel assignments. The replacement settings should correspond with the existing control-system design.
Its ability to handle voltage, current, resistance, RTD and thermocouple signals can reduce the need for several different specialised modules. This is useful where a control panel receives measurements from a varied group of industrial sensors.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.