steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | A9F77150 |
| Manufacturer | Telemecanique |
| Product Type | Miniature Circuit Breaker |
| Device Application | Distribution |
| Range | Acti 9 |
| Product Name | Acti 9 iC60 |
| Device Short Name | IC60N |
| Poles Description | 1P |
| Number of Protected Poles | 1 |
| Rated Current [In] | 50 A |
| Network Type | AC/DC |
| Trip Unit Technology | Thermal-magnetic |
| Curve Code | C |
| Breaking Capacity Code | N |
| Breaking Capacity | 10 kA Icu conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz, 20 kA Icu conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz, 6000 A Icn conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz |
| Utilisation Category | Category A conforming to EN 60947-2, Category A conforming to IEC 60947-2 |
| Suitability for Isolation | Yes, conforming to EN 60947-2, IEC 60947-2, EN 60898-1, IEC 60898-1 |
| Standards | IEC 60947-2, EN 60947-2, IEC 60898-1, EN 60898-1 |
| Network Frequency | 50/60 Hz |
| Rated Operational Voltage [Ue] | 100...133 V AC 50/60 Hz, 72 V DC, 12...60 V DC, 12...60 V AC 50/60 Hz, 220...240 V AC 50/60 Hz, 230 V AC 50/60 Hz |
| Magnetic Tripping Limit | 8 x In +/- 20% |
| Rated Service Breaking Capacity [Ics] | 10 kA 100% x Icu conforming to EN 60947-2 - 72 V DC, 10 kA 100% x Icu conforming to IEC 60947-2 - 72 V DC, 6000 A 100% x Icu conforming to IEC 60898-1 - 230 V AC 50/60 Hz |
| Rated Insulation Voltage [Ui] | 500 V AC 50/60 Hz conforming to IEC 60947-2, 500 V AC 50/60 Hz conforming to EN 60947-2 |
| Rated Impulse Withstand Voltage [Uimp] | 6 kV conforming to EN 60947-2, 6 kV conforming to IEC 60947-2 |
| Contact Position Indicator | Yes |
| Control Type | Toggle |
| Local Signalling | Trip indicator |
| Mounting Mode | Fixed |
| Mounting Support | DIN rail |
| Comb Busbar and Distribution Block Compatibility | Yes, top or bottom |
| Connection Pitch | 18 mm between devices, 9 mm pitches |
| Height | 85 mm |
| Width | 18 mm |
| Depth | 78.5 mm |
| Product Weight | 0.215 kg |
| Colour | White |
| Mechanical Durability | 20000 cycles |
| Electrical Durability | 10000 cycles |
| Connections - Terminals | Single terminal, top or bottom rigid wire(s) 1...35 mm² max, Single terminal, top or bottom flexible wire(s) 1...25 mm² max |
| Wire Stripping Length | 14 mm top or bottom |
| Tightening Torque | 3.5 N.m top or bottom |
| Earth-leakage Protection | Without |
| Compatibility Code | IC60 |
| IP Degree of Protection | IP20 conforming to EN 60529, IP20 conforming to IEC 60529 |
| Pollution Degree | 3 conforming to EN 60947-2, 3 conforming to IEC 60947-2 |
| Overvoltage Category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative Humidity | 95% (55 °C) |
| Operating Altitude | 0...2000 m |
| Ambient Air Temperature for Operation | -35...70 °C |
| Ambient Air Temperature for Storage | -40...85 °C |
This part is primarily used for electrical distribution and protection in both AC and DC networks.
The device has a rated current of 50 A.
This is a miniature circuit breaker with a thermal-magnetic trip unit technology.
The breaking capacity is 10 kA Icu conforming to EN/IEC 60947-2 at 220...240 V AC 50/60 Hz.
Yes, it is suitable for isolation conforming to EN 60947-2 and IEC 60947-2 standards.
The device has an IP20 degree of protection conforming to EN 60529 and IEC 60529.
The device can operate in ambient air temperatures ranging from -35 to 70 °C and at altitudes up to 2000 meters.
The mechanical durability of the circuit breaker is 20,000 cycles.
Yes, this part is RoHS compliant as per the Schneider Electric declaration of conformity.
The rated insulation voltage is 500 V AC 50/60 Hz conforming to IEC 60947-2.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.