steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Square D |
| Part Number | HGA36100 |
| Product Range | PowerPact H |
| Product Type | I-Line moulded case circuit breaker |
| Description | Three-pole, 100 A thermal-magnetic circuit breaker designed for overload and short-circuit protection in compatible I-Line distribution panels and switchboards. |
| Rated Current | 100 A |
| Number of Poles | 3 |
| Protected Poles | 3 |
| Trip Unit Technology | Thermal-magnetic |
| AC Voltage Rating | 600 V AC |
| DC Voltage Ratings | 250 V DC and 500 V DC |
| Network Frequency | 50/60 Hz |
| AC Breaking Capacity | 65 kA at 240 V AC; 35 kA at 480 V AC; 18 kA at 600 V AC, to UL 489 |
| DC Breaking Capacity | 20 kA at 250 V DC and 500 V DC, to UL 489 |
| Breaking Capacity Code | G |
| Continuous Current Rating | 80% rated |
| Magnetic Hold Current | 900 A |
| Magnetic Tripping Current | 1,700 A |
| Operation | Manual toggle |
| Mounting Type | I-Line plug-on |
| Line Connection | I-Line connection |
| Load Connection | Cable lugs |
| Phase Connection | ABC |
| Conductor Compatibility | Copper or aluminium |
| Conductor Size Range | 14 AWG to 3/0 AWG |
| Load Terminal Reference | AL150HD |
| Mounting Height | 114.3 mm |
| Rated Insulation Voltage | 750 V to IEC 60947-2 |
| Rated Impulse Withstand Voltage | 8 kV to IEC 60947-2 |
| Utilisation Category | Category A |
| Colour | Black |
The HGA36100 is a PowerPact H-frame moulded-case circuit breaker with thermal-magnetic protection. It is designed for electrical distribution applications and uses an I-Line plug-on mounting system.
This circuit breaker is rated at 100 A and has three protected poles, making it suitable for compatible three-phase distribution circuits.
The thermal element provides protection against sustained overloads, while the magnetic element responds to high short-circuit currents. The magnetic hold current is 900 A and the magnetic tripping current is 1,700 A.
The HGA36100 has a rated AC voltage of 600 V and operates at a network frequency of 50/60 Hz. Its interrupting capacity varies with the operating voltage.
The interrupting ratings under UL 489 are 65 kA at 240 V AC, 35 kA at 480 V AC and 18 kA at 600 V AC. Selection should account for both the system voltage and the prospective short-circuit current at the installation point.
This breaker uses an I-Line plug-on arrangement for compatible I-Line panelboards and switchboards. It has an I-Line connection on the supply side and lug terminals on the load side.
The ABC designation identifies the breaker's phase connection arrangement within the I-Line system. This arrangement should be checked against the intended panelboard or switchboard configuration.
The load terminals accommodate copper or aluminium conductors from AWG 14 to AWG 3/0. The specified terminal identifier is AL150HD. Conductor selection and termination must follow the applicable installation instructions.
No. The HGA36100 has an 80% continuous-current rating. This distinction must be considered when sizing the breaker for continuous loads.
The published specifications list an interrupting rating of 20 kA at both 250 V DC and 500 V DC. Suitability depends on the DC circuit configuration and the manufacturer's required pole connection arrangement, so the voltage rating alone is not sufficient to establish compatibility.
The front cover is rated IP40 to IEC 60529. This rating applies to the front cover rather than to a complete installed enclosure, so the surrounding panel must provide the protection required by the application.
Check the 100 A current rating, three-pole configuration, operating voltage, interrupting capacity, thermal-magnetic trip characteristics, ABC phase arrangement and I-Line mounting compatibility. Terminal requirements and installation clearances should also be verified rather than relying on the current rating alone.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.