steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 1116334 |
| Manufacturer | Sick |
| Product Family | TMS/TMM22 |
| Type | Inclination Sensor |
| Number of Axes | 2 |
| Measuring Range | ± 10° |
| Resolution | ≤ 0.015° |
| Error Limits | Typical 0.25°, Maximum 0.6° |
| Repeatability | Standard deviation σr: 30 μA |
| Cross-Sensitivity | Compensated, Typical ± 0.5°, Maximum ± 0.9° |
| Temperature Coefficient | ±0.03°/K |
| Limit Frequency | 2 Hz |
| Sampling Rate | 400 Hz |
| Communication Interface | Analog / Current |
| Current Output | 4 mA ... 20 mA |
| Load Resistance | 200 Ω ... 900 Ω |
| Initialization Time | 250 ms |
| Supply Voltage | 12 V DC ... 30 V DC |
| Current Consumption | < 30 mA (+ Iloop) @ 24 V |
| Reverse Polarity Protection | Yes |
| Short-Circuit Protection | Yes |
| MTTFd | 961 years (EN ISO 13849-1) |
| Dimensions | 38.8 mm x 30 mm x 10.4 mm |
| Weight | Approx. 60 g |
| Housing Material | Plastic (PA12), glass-fiber reinforced |
| Cable Material | PUR |
| Enclosure Rating | IP66, IP67, IP68, IP69K |
| Operating Temperature Range | –40 °C ... +80 °C |
| Storage Temperature Range | –40 °C ... +85 °C |
| Shock Resistance | 100 g, 6 ms (EN 60068-2-27) |
| Vibration Resistance | 10 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) |
| Classification | eCl@ss 10.0: 27271101, ETIM 8.0: EC001852, UNSPSC 16.0901: 41111613 |
The Sick TMM22E-PKH010 is a high-precision inclination sensor designed for industrial applications requiring accurate tilt measurement. With a dual-axis measuring range of ±10°, it offers exceptional resolution and error limits, making it ideal for environments where precision is critical. The sensor is robustly constructed with a glass-fiber reinforced plastic housing, ensuring durability in harsh conditions. It features a wide operating temperature range and high resistance to shock and vibration, making it suitable for a variety of industrial settings. The sensor's analog current output and compatibility with standard interfaces ensure seamless integration into existing systems.
The Sick 1116334 is an inclination sensor, designed to measure angles of tilt or inclination in various industrial applications.
The Sick 1116334 has a measuring range of ±10 degrees, allowing it to accurately detect and measure small changes in inclination.
The dimensions of the Sick 1116334 are 38.8 mm x 30 mm x 10.4 mm, making it compact and suitable for various installation environments.
The Sick 1116334 can operate in temperatures ranging from -40 °C to +80 °C, making it suitable for use in a wide range of environmental conditions.
The Sick 1116334 has an enclosure rating of IP66, IP67, IP68, and IP69K, indicating its high level of protection against dust and water ingress.
The Sick 1116334 offers a resolution of ≤ 0.015°, providing precise measurements for applications requiring high accuracy.
The housing of the Sick 1116334 is made from glass-fiber reinforced plastic (PA12), and the cable is made from PUR, ensuring durability and reliability.
Yes, the Sick 1116334 is equipped with short-circuit protection to safeguard its outputs from potential damage.
The Sick 1116334 has a mean time to dangerous failure (MTTFd) of 961 years, as per EN ISO 13849-1 standards, indicating its reliability and longevity.
The Sick 1116334 provides an analog current output ranging from 4 mA to 20 mA, suitable for integration with various control systems.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.