steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | SICK |
| Part Number | 1016478 |
| Model | C20E-060303A11 |
| Product Range | C2000 Standard |
| Product Type | Safety light curtain receiver |
| Protective Field Height | 600 mm |
| Resolution | 30 mm |
| Housing Cross-Section | 34 mm × 29 mm |
| Response Time | ≤ 34 ms |
| Synchronisation | Optical |
| Device Type | Type 2 to IEC 61496-1 |
| Safety Integrity Level | SIL 1 to IEC 61508 |
| Performance Level | PL c to EN ISO 13849 |
| Category | Category 2 to EN ISO 13849 |
| Internal Test Rate | 13 tests per second |
| Maximum Demand Rate | ≤ 8 per minute |
| PFHD | 2.2 × 10⁻⁸ per hour |
| Mission Time | 20 years |
| Outputs | Two PNP semiconductor OSSD outputs |
| OSSD Current Capacity | ≤ 500 mA per output |
| OSSD High-State Voltage | 24 V DC, from supply voltage minus 2.25 V up to supply voltage |
| OSSD Low-State Voltage | ≤ 3.5 V DC |
| External Device Monitoring | Included and activated |
| Beam Coding | Included; supplied uncoded |
| System Connection | M12 male connector, 8-pin |
| Configuration | Hard-wired |
| Display | 7-segment display with LED status indicators |
| Permitted Cable Length | ≤ 15 m |
| Conductor Cross-Section | 0.25 mm² |
| Protection Class | Class III to EN 50178 |
| Enclosure Rating | IP65 to EN 60529 |
| Operating Temperature | 0 °C to +55 °C |
| Storage Temperature | −25 °C to +70 °C |
| Relative Humidity | 15% to 95%, non-condensing |
| Vibration Resistance | 5 g at 10 Hz to 55 Hz |
| Shock Resistance | 10 g for 16 ms |
| UNSPSC | 46171620 |
| ECLASS | 27272704 |
| ETIM | EC002549 |
It is a receiver unit from the SICK C2000 Standard range of Type 2 safety light curtains, designed to detect interruptions within a machine-guarding protective field.
The receiver has a protective field height of 600 mm.
The specified resolution is 30 mm, making it suitable for detecting objects that interrupt the protected area.
The response time is no more than 34 ms under the specified operating conditions.
The unit is classified as Type 2 under IEC 61496-1, Category 2 and PL c under EN ISO 13849, and SIL 1 under IEC 61508.
It provides two PNP semiconductor OSSD outputs. The outputs are short-circuit protected and monitored for cross-circuit faults, with a maximum current capacity of 500 mA per OSSD.
The receiver uses an 8-pin male M12 system connector. The permitted connecting cable length is up to 15 m, subject to a maximum conductor resistance of 4 ohms.
The housing is rated IP65 in accordance with EN 60529, providing protection against dust and water jets when correctly installed.
SICK 1016478 is specified for operation from 0°C to +55°C and storage from -25°C to +70°C. Permitted relative humidity is 15% to 95%, non-condensing.
The housing has a compact cross-section of 34 mm by 29 mm. The full mounting dimensions should be checked against the existing installation before replacement.
Yes. External device monitoring, also known as EDM, is included and is activated in the factory configuration.
The C2000 Standard system uses optical synchronisation, so a separate synchronisation connection between the transmitter and receiver is not required.
For new machinery placed into service from 10 May 2015, this Type 2 device is limited to applications requiring no more than PL c or SIL 1 under the stated standards. The machine's risk assessment and applicable UK regulations must be reviewed before installation.
Within the relevant European regulatory framework, this Type 2 model may be used as a replacement for an identical PL d or SIL 2 device only where the original machine was placed on the market before 10 May 2015. The replacement note should remain with the machine documentation.
Specified accessories include the AR60 laser alignment aid, the DOS-1208-G straight 8-pin M12 female connector and the BEF-1SHABAZN4 side-mounting bracket set. Accessory suitability should be confirmed against the existing installation.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.