steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | XCMD2102M12 |
| Alternative Part Number | XCMD2102M12 |
| Manufacturer | Schneider |
| Product Type | Limit Switch |
| Series | OsiSense XC, Standard format |
| Sensor Design | Miniature |
| Body Type | Plug-in body |
| Head Type | Plunger head |
| Material | Metal, with Zamak body and head |
| Fixing Mode | By the body |
| Movement of Operating Head | Linear |
| Type of Operator | Spring return roller plunger metal |
| Type of Approach | Lateral approach 2 directions |
| Number of Poles | 1 |
| Contacts Type and Composition | 1 C/O (Changeover) |
| Contacts Operation | Snap action |
| Switch Actuation | By 30° cam |
| Electrical Connection | Male connector M12, 4 pins |
| Rated Operational Current | 0.1 A at 250 V, DC-13; 1.5 A at 240 V, AC-15 |
| Conventional Enclosed Thermal Current | 3 A |
| Rated Insulation Voltage | 250 V (degree of pollution 3) |
| Resistance Across Terminals | <= 25 MOhm |
| Rated Impulse Withstand Voltage | 2.5 kV |
| Short Circuit Protection | 4 A by gG cartridge fuse |
| Electrical Durability | 5,000,000 cycles at various DC voltages and conditions |
| Mechanical Durability | 10,000,000 cycles |
| Dimensions (Width x Height x Depth) | 30 mm x 50 mm x 16 mm |
| Product Weight | 0.09 kg |
| Shock Resistance | 25 gn (duration = 18 ms) |
| Vibration Resistance | 5 gn (f = 10...500 Hz) |
| IP Degree of Protection | IP66, IP67, IP68 |
| IK Degree of Protection | IK06 |
| Ambient Air Temperature for Operation | -25...70 °C |
| Ambient Air Temperature for Storage | -40...70 °C |
| Protective Treatment | TC |
| Product Certifications | CCC, CSA, UL |
| Standards | EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 |
| Sustainable Offer Status | Green Premium product |
This is a spring return roller lever limit switch with a miniature design. It features a steel roller plunger, 1 normally closed (NC) and 1 normally open (NO) contact, snap action, and an M12 4-pin male connector for electrical connection.
The body and head material of the limit switch are made of Zamak, a zinc aluminium alloy, providing robustness and durability. It has a mechanical durability of 10 million cycles, ensuring long-term reliability in various applications.
The limit switch has a rated operational current of 1 A at 24 V DC-13, a conventional enclosed thermal current of 3 A, and a rated insulation voltage of 250 V. It also has a short-circuit protection with a 4 A cartridge fuse, type gG.
The limit switch offers an IP degree of protection of IP66, IP67, and IP69, indicating a high level of protection against dust and water ingress, making it suitable for use in harsh environmental conditions.
The limit switch is certified by UL, CCC, and CSA, ensuring compliance with international safety and quality standards.
The ambient operating temperature range for the limit switch is between -25°C and 70°C, allowing it to function effectively in a wide range of environmental conditions.
The limit switch is mounted by the body with 2 fixing holes that are Ø 4.2 mm, counterbored Ø 8 mm by 4 mm deep, providing a secure and stable installation.
The maximum actuation speed for the limit switch is 0.5 m/s, with a minimum force for tripping of 7 N and a positive opening minimum force of 35 N.
The positive opening feature ensures that the NC contacts will open when the actuator is engaged, even if the contacts have become welded, providing an additional safety measure for critical applications.
The switch actuation is performed by a 30° cam, which allows for precise and reliable operation when the roller lever is engaged by the moving part of the machinery.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.