steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LA1KN223 |
| Manufacturer | Schneider |
| Product Type | Auxiliary Contact Block |
| Range | TeSys |
| Device Short Name | LA1 |
| Range Compatibility | TeSys K LC1K, TeSys K CA2K, TeSys K CA3K |
| Mounting Location | Front |
| Pole Contact Composition | 2 NO (Normally Open) + 2 NC (Normally Closed) |
| Contacts Operation | Instantaneous |
| Rated Operational Voltage | 690 V AC 25...400 Hz |
| Rated Insulation Voltage | 690 V IEC 60947-5-1, 600 V UL 60947-5-1, 600 V CSA C22.2 No 60947-5-1 |
| Conventional Free Air Thermal Current | 10 A at 50°C (122°F) |
| Standards | EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5 |
| Product Certifications | IECEE CB Scheme, UL, CSA, CCC |
| Rated Making Capacity | 110 A <= 690 V AC IEC 60947 |
| Permissible Short-time Rating | 80 A for 1 s, 60 A for 500 ms, 110 A for 100 ms |
| Associated Fuse Rating | 10 A gG <= 690 V IEC 60947 |
| Minimum Switching Current | 5 mA |
| Minimum Switching Voltage | 17 V |
| Non-overlap Distance | 0.5 mm |
| Insulation Resistance | > 10 MOhm |
| Connections - Terminals | Spring terminals for 0.75…1.5 mm² flexible without cable end, and rigid wires |
| Height | 30 mm |
| Width | 38 mm |
| Depth | 35 mm |
| Net Weight | 0.045 kg |
| Environmental Characteristic | Normal environment |
| IP Degree of Protection | IP20 conforming to IEC 60529 |
| Protective Treatment | TC conforming to IEC 60068 |
| Ambient Air Temperature for Operation | -25…50°C |
| Ambient Air Temperature for Storage | -50…80°C |
| Operating Altitude | Up to 2000 m without derating |
The auxiliary contact block is used to provide additional switching functions in a control circuit. It typically operates in conjunction with a main contactor or relay to facilitate the control of electrical circuits.
This contact block is designed for front mounting and is compatible with TeSys K LC1K, TeSys K CA2K, and TeSys K CA3K series devices.
The contact block comes with a pole contact composition of 2 Normally Open (NO) and 2 Normally Closed (NC) contacts.
It is equipped with spring terminals that can accommodate flexible wires without cable ends as well as solid wires.
The rated operational voltage for the contact block is 690 V AC at frequencies ranging from 25 to 400 Hz.
The contact block can operate in normal environmental conditions, with an ambient air temperature range for operation of -25 to 50°C and for storage of -50 to 80°C. It also has an operating altitude of up to 2000 metres without derating.
The contact block has an IP20 degree of protection, conforming to IEC 60529 standards.
The contact block measures approximately 30 mm in height, 38 mm in width, and 35 mm in depth, with a net weight of around 0.045 kg.
It meets EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5, and JIS C8201-5-1 standards, and holds product certifications such as CB Scheme, CCC, UL, CSA, CE, and UKCA.
The contact block is a Green Premium product, which means it is compliant with REACh and EU RoHS directives, free of SVHC (Substances of Very High Concern), toxic heavy metals, and mercury. It also has a China RoHS declaration and must be disposed of according to specific waste collection in the European Union.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.