steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Manufacturer Part Number | C254250S |
| Product Range | ComPacT new generation |
| Product Name / Series | ComPacT NSX new generation |
| Device Short Name | NSX250NA |
| Product Type | Switch disconnector |
| Part Description (English, UK) | Schneider Electric ComPacT NSX250NA switch disconnector (C254250S), a fixed, 4‑pole isolating switch designed for distribution applications, providing a clear contact position indication and robust electrical performance across a wide AC and DC operating range. |
| Application | Distribution |
| Poles | 4P |
| Mounting Mode | Fixed |
| Control Type | Toggle |
| Suitability for Isolation | Yes (conforming to EN/IEC 60947-3) |
| Contact Position Indicator | Yes |
| Visible Break | No |
| Conventional Free Air Thermal Current (Ith) | 250 A at 50 °C |
| Rated Operational Current (Ie) – AC | AC-22A: 250 A, 220…690 V AC, 50/60 Hz; AC-23A: 250 A, 220…690 V AC, 50/60 Hz |
| Rated Operational Current (Ie) – DC | DC-22A: 250 A at 250 V DC (1 pole); 250 A at 500 V DC (2 poles in series); 250 A at 750 V DC (3 poles in series). DC-23A: 250 A at 250 V DC (1 pole); 250 A at 500 V DC (2 poles in series); 250 A at 750 V DC (3 poles in series). |
| Rated Operational Voltage (Ue) | 690 V AC (50/60 Hz); 250 V DC (1 pole); 500 V DC (2 poles in series); 750 V DC (3 poles in series) |
| Network Type | AC / DC |
| Utilisation Categories | AC-22A, AC-23A, DC-22A, DC-23A |
| Breaking Capacity Code | NA |
| Rated Short-Time Withstand Current (Icw) | 3.5 kA for 1 s; 3.5 kA for 3 s; 1.35 kA for 20 s |
| Rated Short-Circuit Making Capacity (Icm) | 330 kA with upstream protection circuit breaker; 4.9 kA (switch disconnector alone) |
| Rated Insulation Voltage (Ui) | 800 V AC (50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Mounting Support | Backplate |
| Connection Location | Front (upside); Front (downside) |
| Connection Pitch | 35 mm |
| Mechanical Durability | 20,000 cycles |
| Electrical Durability (selected values) | AC-22A: 15,000 cycles at 440 V AC In/2; 7,500 cycles at 440 V AC In; 6,000 cycles at 690 V AC In/2; 3,000 cycles at 690 V AC In. DC-22A: 10,000 cycles at 250 V DC In/2 (1 pole); 5,000 cycles at 500 V DC In (2 poles in series). (Same values listed for AC-23A / DC-23A.) |
| Standards | EN/IEC 60947-1; EN/IEC 60947-3 |
| Product Certifications | CE; EAC; CCC |
| IP Rating | IP40 (IEC 60529) |
| IK Rating | IK07 (IEC 62262) |
| Electrical Shock Protection Class | Class II |
| Pollution Degree | 3 (IEC 60664-1) |
| Operating Ambient Temperature | -25…70 °C |
| Storage Ambient Temperature | -50…85 °C |
| Dimensions (W × H × D) | 140 mm × 161 mm × 86 mm |
| Net Weight | 2.2 kg |
| RoHS / REACH | EU RoHS compliant; REACH declaration available |
| Mercury Content | Mercury free (Yes) |
| PVC Content | PVC free (Yes) |
It is a switch disconnector used to manually switch circuits on/off and provide isolation for downstream equipment in distribution applications. It is suitable for isolation in accordance with EN/IEC 60947-3.
It is a 4-pole (4P) device, commonly used for three-phase systems where neutral switching/isolation is also required.
The conventional free-air thermal current (Ith) is 250 A at 50 °C.
For AC-22A and AC-23A duties, the rated operational current (Ie) is 250 A at 50/60 Hz across 220 to 690 V AC.
Yes. It supports DC-22A and DC-23A duties at 250 A, with voltage dependent on pole configuration (for example 250 V DC with 1 pole, 500 V DC with 2 poles in series, and up to 750 V DC with 3 poles in series).
Rated operational voltage (Ue) is up to 690 V AC (50/60 Hz). For DC use, it can be configured up to 750 V DC when using 3 poles in series (application dependent).
No. It has a contact position indicator, but it does not provide a visible break.
It is rated for AC-22A, AC-23A, DC-22A and DC-23A. These categories indicate suitability for switching different types of loads (for example, AC-23A is typically associated with more demanding motor-related switching duties than AC-22A).
Rated short-time withstand current (Icw) is 3.5 kA for 1 s, 3.5 kA for 3 s, and 1.35 kA for 20 s.
Rated short-circuit making capacity (Icm) is up to 330 kA when used with an upstream protection circuit breaker. On its own, the switch-disconnector making capacity is 4.9 kA.
Rated insulation voltage (Ui) is 800 V AC (50/60 Hz) and rated impulse withstand voltage (Uimp) is 8 kV.
It uses a toggle control for manual switching.
It is a fixed mounting design with backplate mounting support. Both the upstream and downstream connections are made from the front, with a 35 mm connection pitch.
Mechanical durability is rated at 20,000 cycles. Electrical durability depends on duty and voltage; for example, up to 15,000 cycles at 440 V AC (AC-22A/AC-23A) at In/2, and up to 3,000 cycles at 690 V AC at In.
It is rated IP40 for ingress protection and IK07 for impact resistance (as per IEC standards).
Ambient operating temperature range is -25 to 70 °C, and ambient storage temperature range is -50 to 85 °C.
Overall dimensions are approximately 140 mm (W) x 161 mm (H) x 86 mm (D). Net weight is approximately 2.2 kg. This helps with enclosure space and mounting layout planning.
It is specified as Class II for electrical shock protection.
It is designed to comply with EN/IEC 60947-1 and EN/IEC 60947-3, which cover low-voltage switchgear/controlgear and switch disconnectors.
It is typically used in low-voltage distribution panels where a robust on/off switching device with isolation capability is required for feeders, sub-distribution circuits, or load switching within industrial and commercial installations.
Confirm the required DC voltage and ensure the correct pole-in-series arrangement is feasible in your design (for example, 2 poles in series for 500 V DC or 3 poles in series for 750 V DC), and verify the duty category (DC-22A or DC-23A) matches the load switching requirements. If needed, reference the unit as Schneider C254250S when documenting the build.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.