steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | A9F94306 |
| Manufacturer | Schneider |
| Product Type | Miniature Circuit Breaker (MCB) |
| Range | Acti9 |
| Product Name | Acti9 iC60 |
| Device Application | Distribution |
| Poles Description | 3P (Three Poles) |
| Number of Protected Poles | 3 |
| Rated Current [In] | 6 A |
| Network Type | AC/DC |
| Trip Unit Technology | Thermal-Magnetic |
| Curve Code | C |
| Breaking Capacity | 15,000 A Icn at 400 V AC 50/60 Hz (EN/IEC 60898-1), 50 kA Icu at 220-240 V AC 50/60 Hz (EN/IEC 60947-2), 70 kA Icu at 12-60 V AC 50/60 Hz (EN/IEC 60947-2), 70 kA Icu at 100-133 V AC 50/60 Hz (EN/IEC 60947-2), 20 kA Icu at 440 V AC 50/60 Hz (EN/IEC 60947-2), 25 kA Icu at 380-415 V AC 50/60 Hz (EN/IEC 60947-2), 20 kA Icu at <= 180 V DC (EN/IEC 60947-2) |
| Rated Insulation Voltage [Ui] | 500 V AC 50/60 Hz (EN/IEC 60947-2) |
| Rated Impulse Withstand Voltage [Uimp] | 6 kV (EN/IEC 60947-2) |
| Control Type | Toggle |
| Local Signalling | Trip Indicator |
| Mounting Mode | Fixed |
| Mounting Support | DIN Rail |
| Comb Busbar Compatibility | Top or Bottom |
| 9 mm Pitches | 6 |
| Height | 85 mm |
| Width | 54 mm |
| Depth | 78.5 mm |
| Net Weight | 0.375 kg |
| Colour | White |
| Mechanical Durability | 20,000 cycles |
| Electrical Durability | 10,000 cycles |
| Connections - Terminals | Single terminal (top or bottom) 1-25 mm² rigid, Single terminal (top or bottom) 1-16 mm² flexible |
| Wire Stripping Length | 14 mm (top or bottom) |
| Tightening Torque | 2 N.m (top or bottom) |
| Earth-leakage Protection | Separate Block |
| IP Degree of Protection | IP20 (EN/IEC 60529) |
| Pollution Degree | 3 (EN/IEC 60947-2) |
| Overvoltage Category | IV |
| Tropicalisation | 2 (IEC 60068-1) |
| Relative Humidity | 95% at 55°C |
| Operating Altitude | 0-2000 m |
| Ambient Air Temperature for Operation | -35 to 70°C |
| Ambient Air Temperature for Storage | -40 to 85°C |
| Sustainable Offer Status | Green Premium Product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Compliant with Exemptions |
| Mercury Free | Yes |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | No need for specific recycling operations |
| WEEE | The product must be disposed of on European Union markets following specific waste collection and never end up in rubbish bins |
| Halogen Content Performance | Halogen Free Product |
The rated current for the Schneider A9F94306 miniature circuit breaker is 16 A.
The Schneider A9F94306 circuit breaker uses a DIN rail mounting support.
The Schneider A9F94306 has a breaking capacity of 35 kA.
The dimensions of the Schneider A9F94306 are 72 x 78.5 x 85 mm.
The Schneider A9F94306 uses thermal magnetic tripping technology.
Yes, the Schneider A9F94306 is suitable for isolation.
The rated insulation voltage of the Schneider A9F94306 is 500 V AC.
The Schneider A9F94306 has an IP20 degree of protection.
The mechanical durability of the Schneider A9F94306 is 20,000 cycles.
The electrical durability of the Schneider A9F94306 is 10,000 cycles.
The rated impulse withstand voltage of the Schneider A9F94306 is 6 kV.
The Schneider A9F94306 uses a toggle control type.
The operating temperature range for the Schneider A9F94306 is -35 to 70 °C.
The Schneider A9F94306 has a pollution degree of 3.
The overvoltage category for the Schneider A9F94306 is IV.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.