steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Red Lion |
| Part Number | PAXP |
| Product Type | Process input panel meter |
| Meter Format | 1/8 DIN analogue input panel meter |
| Primary Function | Displays and scales industrial process signals for monitoring and measurement applications |
| Input Type | Process input |
| Input Ranges | 20 mA and 10 VDC process signal ranges |
| Current Input Range | -2 to 26 mA |
| Voltage Input Range | -1 to 13 VDC |
| Display | 5-digit LED display |
| Display Range | -19999 to 99999 |
| Display Character Height | 0.56 in / 14.2 mm |
| Display Options | Red sunlight-readable or standard green display, depending on variant |
| Display Intensity | Adjustable display intensity |
| A/D Converter | 16-bit resolution |
| A/D Conversion Rate | 20 readings per second |
| Display Update Rate | 1 to 20 updates per second |
| Current Input Accuracy | 0.03% of reading + 2 µA at 18 to 28°C; 0.12% of reading + 3 µA at 0 to 50°C |
| Voltage Input Accuracy | 0.03% of reading + 2 mV at 18 to 28°C; 0.12% of reading + 3 mV at 0 to 50°C |
| Current Input Impedance | 20 ohm |
| Voltage Input Impedance | 500 kohm |
| Current Input Maximum Continuous Overload | 150 mA |
| Voltage Input Maximum Continuous Overload | 300 V |
| Current Display Resolution | 1 µA |
| Voltage Display Resolution | 1 mV |
| Transmitter Power | 24 VDC ±5%, regulated, 50 mA maximum |
| Scaling | Up to 16-point scaling for non-linear process signals |
| Totalizer | 9-digit totalizer/integrator with batching capability |
| Memory | Non-volatile E2PROM retains programmed parameters and display values |
| Function Keys | 3 programmable function keys, 5 keys total |
| User Inputs | 3 programmable user inputs |
| User Input Logic | Jumper-selectable sinking or sourcing logic |
| Setpoint Capability | Up to 4 setpoint alarm outputs with suitable option card |
| Communication Capability | Optional communication card capability, including serial and fieldbus formats depending on fitted card |
| Analogue Output Capability | Optional retransmitted analogue output card for 0 to 20 mA, 4 to 20 mA or 0 to 10 VDC |
| Power Supply Options | 85 to 250 VAC version, or 11 to 36 VDC / 24 VAC version depending on model configuration |
| AC Power Rating | 85 to 250 VAC, 50/60 Hz, 15 VA |
| DC Power Rating | 11 to 36 VDC, 11 W |
| Low Voltage AC Power Rating | 24 VAC ±10%, 50/60 Hz, 15 VA |
| Operating Temperature | 0 to 50°C, or 0 to 45°C with all three option cards installed |
| Storage Temperature | -40 to 60°C |
| Humidity | 0 to 85% RH, non-condensing |
| Altitude | Up to 2000 m |
| Front Enclosure Rating | NEMA 4X / IP65 face rating when correctly panel mounted |
| Rear Enclosure Rating | IP20 |
| Panel Cut-Out | 92 mm x 45 mm nominal cut-out |
| Approximate Dimensions | 96.5 mm wide x 49.5 mm high x 104.1 mm deep |
| Connections | High-compression cage-clamp terminal block |
| Wire Size | 30 to 14 AWG copper wire |
| Recommended Strip Length | 7.5 mm |
| Terminal Torque | 0.51 N-m maximum |
| Weight | 295 g |
| Certifications and Compliance | CE approved, RoHS compliant, UL listed |
| Commodity Code | 903033 |
This process input panel meter is suited to industrial measurement and display applications where analogue process signals need to be converted into a clear local readout. Typical uses include monitoring pressure, flow, level, temperature transmitter outputs, and other process variables using 20 mA or 10 VDC signal ranges.
The Red Lion PAXP is designed for process inputs and supports a 20 mA range, covering -2 to 26 mA, and a 10 VDC range, covering -1 to 13 VDC. This makes it suitable for common industrial transmitter signals such as 4-20 mA and 0-10 V.
Yes. The process input version includes regulated 24 VDC transmitter power rated up to 50 mA, allowing it to power compatible 2-wire or 3-wire process transmitters when wired correctly.
The unit uses a 5-digit LED display with 0.56 inch characters. Depending on the specific configuration, the PAX range can be supplied with a red sunlight-readable display or a green display, with adjustable display intensity.
Yes. The meter can be programmed so that the incoming process signal corresponds to a chosen display value. This allows a 4-20 mA or 0-10 V process signal to be displayed in engineering units such as bar, litres, metres, percentage, RPM, or other application-specific values.
Yes. The PAX analogue meter platform supports up to 16 scaling point pairs, which can be used for non-linear process applications where a simple two-point linear scale is not sufficient.
Yes. The meter includes MAX and MIN reading memory. Capture delay settings can be programmed to help prevent brief spikes or process disturbances from being stored as false maximum or minimum values.
Yes. The meter includes a 9-digit totalizer, also described as an integrator. It can accumulate a process value over a selected time base, or it can be configured for batch-style accumulation using a user input or function key.
Alarm output capability can be added with a compatible setpoint option card. Depending on the card fitted, the meter can provide relay, open collector, triac, or SSR drive style outputs, with up to four setpoint alarm outputs available.
Yes. With the appropriate analogue output option card fitted, the meter can provide a retransmitted output such as 0-20 mA, 4-20 mA, or 0-10 VDC. The output can be scaled independently and assigned to track the input, totalizer, maximum, or minimum reading.
Compatible communication option cards are available for serial and fieldbus integration, including RS232, RS485, Modbus, DeviceNet, and Profibus-DP versions. Only one communications card can be installed at a time.
The PAX meter platform can accept up to three option cards, with one card from each functional group: setpoint alarms, communications, and analogue output. This allows the meter to be expanded for control, signalling, or integration functions.
The PAX analogue panel meter range is available in AC and low-voltage power versions. AC versions operate from 85 to 250 VAC, while DC versions operate from 11 to 36 VDC and can also accept 24 VAC.
The meter is a 1/8 DIN panel instrument. The panel cut-out is approximately 92 mm by 45 mm, making it suitable for standard industrial panel mounting arrangements.
When correctly installed into a suitable panel, the front bezel is rated to NEMA 4X and IP65. The rear of the unit is rated IP20.
The general operating temperature range is 0 to 50°C. If all three option card positions are populated, the specified operating range is reduced to 0 to 45°C.
Electrical connections are made using screw-clamp terminals on the rear of the meter. The terminals accept copper conductors within the specified gauge range, and the wiring position should be matched to the terminal numbering on the rear case.
The meter includes three programmable user inputs. These can be assigned to functions such as display hold, totalizer reset, batch accumulation, maximum or minimum reset, input tare, display selection, print request, or programme lock-out.
Yes. The front panel includes programmable function keys that can be assigned to selected meter functions. Some keys can also have secondary functions that activate after being held for a defined period.
An over-range display message usually indicates that the measured signal is outside the configured input range or that the input wiring, scaling, or signal level should be checked. The meter can show different messages for signal high, signal low, or display value overflow conditions.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.