The Red Lion PAXP is a process input panel meter designed for accurate monitoring and display of industrial analogue process signals. As part of the PAX 1/8 DIN analogue panel meter range, it accepts common process inputs including 20 mA and 10 V DC signals, making it suitable for use with transmitters, sensors and control instrumentation across automation, manufacturing and process environments.

Featuring a clear 5-digit LED display, programmable scaling and a rugged panel-mounted design, the PAXP allows measured signals to be converted into meaningful engineering values for operators and maintenance teams. It supports configurable display resolution, filtering, totalising and min/max capture functions, helping users adapt the meter to a wide variety of measurement applications such as pressure, level, flow, speed or other process variables.

The unit also provides 24 V DC transmitter power, enabling straightforward integration with compatible 2-wire or 3-wire transmitters. Optional expansion cards can add setpoint alarm outputs, serial communication or retransmitted analogue output capability, allowing the PAXP to be tailored to more complex monitoring and control requirements. With its sealed front bezel, compact 1/8 DIN format and robust industrial construction, the Red Lion PAXP is well suited for control panels, machine interfaces and process indication applications.
Specification Description
Manufacturer Red Lion
Part Number PAXP
Product Type Process input panel meter
Meter Format 1/8 DIN analogue input panel meter
Primary Function Displays and scales industrial process signals for monitoring and measurement applications
Input Type Process input
Input Ranges 20 mA and 10 VDC process signal ranges
Current Input Range -2 to 26 mA
Voltage Input Range -1 to 13 VDC
Display 5-digit LED display
Display Range -19999 to 99999
Display Character Height 0.56 in / 14.2 mm
Display Options Red sunlight-readable or standard green display, depending on variant
Display Intensity Adjustable display intensity
A/D Converter 16-bit resolution
A/D Conversion Rate 20 readings per second
Display Update Rate 1 to 20 updates per second
Current Input Accuracy 0.03% of reading + 2 µA at 18 to 28°C; 0.12% of reading + 3 µA at 0 to 50°C
Voltage Input Accuracy 0.03% of reading + 2 mV at 18 to 28°C; 0.12% of reading + 3 mV at 0 to 50°C
Current Input Impedance 20 ohm
Voltage Input Impedance 500 kohm
Current Input Maximum Continuous Overload 150 mA
Voltage Input Maximum Continuous Overload 300 V
Current Display Resolution 1 µA
Voltage Display Resolution 1 mV
Transmitter Power 24 VDC ±5%, regulated, 50 mA maximum
Scaling Up to 16-point scaling for non-linear process signals
Totalizer 9-digit totalizer/integrator with batching capability
Memory Non-volatile E2PROM retains programmed parameters and display values
Function Keys 3 programmable function keys, 5 keys total
User Inputs 3 programmable user inputs
User Input Logic Jumper-selectable sinking or sourcing logic
Setpoint Capability Up to 4 setpoint alarm outputs with suitable option card
Communication Capability Optional communication card capability, including serial and fieldbus formats depending on fitted card
Analogue Output Capability Optional retransmitted analogue output card for 0 to 20 mA, 4 to 20 mA or 0 to 10 VDC
Power Supply Options 85 to 250 VAC version, or 11 to 36 VDC / 24 VAC version depending on model configuration
AC Power Rating 85 to 250 VAC, 50/60 Hz, 15 VA
DC Power Rating 11 to 36 VDC, 11 W
Low Voltage AC Power Rating 24 VAC ±10%, 50/60 Hz, 15 VA
Operating Temperature 0 to 50°C, or 0 to 45°C with all three option cards installed
Storage Temperature -40 to 60°C
Humidity 0 to 85% RH, non-condensing
Altitude Up to 2000 m
Front Enclosure Rating NEMA 4X / IP65 face rating when correctly panel mounted
Rear Enclosure Rating IP20
Panel Cut-Out 92 mm x 45 mm nominal cut-out
Approximate Dimensions 96.5 mm wide x 49.5 mm high x 104.1 mm deep
Connections High-compression cage-clamp terminal block
Wire Size 30 to 14 AWG copper wire
Recommended Strip Length 7.5 mm
Terminal Torque 0.51 N-m maximum
Weight 295 g
Certifications and Compliance CE approved, RoHS compliant, UL listed
Commodity Code 903033

What type of industrial applications is this process input panel meter suited to?

This process input panel meter is suited to industrial measurement and display applications where analogue process signals need to be converted into a clear local readout. Typical uses include monitoring pressure, flow, level, temperature transmitter outputs, and other process variables using 20 mA or 10 VDC signal ranges.

What input signal ranges can the unit accept?

The Red Lion PAXP is designed for process inputs and supports a 20 mA range, covering -2 to 26 mA, and a 10 VDC range, covering -1 to 13 VDC. This makes it suitable for common industrial transmitter signals such as 4-20 mA and 0-10 V.

Does the meter provide power for external transmitters?

Yes. The process input version includes regulated 24 VDC transmitter power rated up to 50 mA, allowing it to power compatible 2-wire or 3-wire process transmitters when wired correctly.

What kind of display does the meter use?

The unit uses a 5-digit LED display with 0.56 inch characters. Depending on the specific configuration, the PAX range can be supplied with a red sunlight-readable display or a green display, with adjustable display intensity.

Can the meter be scaled to show engineering units?

Yes. The meter can be programmed so that the incoming process signal corresponds to a chosen display value. This allows a 4-20 mA or 0-10 V process signal to be displayed in engineering units such as bar, litres, metres, percentage, RPM, or other application-specific values.

Does the unit support non-linear signal scaling?

Yes. The PAX analogue meter platform supports up to 16 scaling point pairs, which can be used for non-linear process applications where a simple two-point linear scale is not sufficient.

Can the meter store maximum and minimum readings?

Yes. The meter includes MAX and MIN reading memory. Capture delay settings can be programmed to help prevent brief spikes or process disturbances from being stored as false maximum or minimum values.

Does the unit include a totalizer function?

Yes. The meter includes a 9-digit totalizer, also described as an integrator. It can accumulate a process value over a selected time base, or it can be configured for batch-style accumulation using a user input or function key.

What options are available for alarm outputs?

Alarm output capability can be added with a compatible setpoint option card. Depending on the card fitted, the meter can provide relay, open collector, triac, or SSR drive style outputs, with up to four setpoint alarm outputs available.

Can the analogue process value be retransmitted to another device?

Yes. With the appropriate analogue output option card fitted, the meter can provide a retransmitted output such as 0-20 mA, 4-20 mA, or 0-10 VDC. The output can be scaled independently and assigned to track the input, totalizer, maximum, or minimum reading.

What communications options can be used with this meter?

Compatible communication option cards are available for serial and fieldbus integration, including RS232, RS485, Modbus, DeviceNet, and Profibus-DP versions. Only one communications card can be installed at a time.

How many option cards can be installed?

The PAX meter platform can accept up to three option cards, with one card from each functional group: setpoint alarms, communications, and analogue output. This allows the meter to be expanded for control, signalling, or integration functions.

What power supply versions are available for the unit?

The PAX analogue panel meter range is available in AC and low-voltage power versions. AC versions operate from 85 to 250 VAC, while DC versions operate from 11 to 36 VDC and can also accept 24 VAC.

What panel cut-out size is required?

The meter is a 1/8 DIN panel instrument. The panel cut-out is approximately 92 mm by 45 mm, making it suitable for standard industrial panel mounting arrangements.

What environmental rating does the front of the meter have?

When correctly installed into a suitable panel, the front bezel is rated to NEMA 4X and IP65. The rear of the unit is rated IP20.

What operating temperature range is specified?

The general operating temperature range is 0 to 50°C. If all three option card positions are populated, the specified operating range is reduced to 0 to 45°C.

What wiring terminals are used on the unit?

Electrical connections are made using screw-clamp terminals on the rear of the meter. The terminals accept copper conductors within the specified gauge range, and the wiring position should be matched to the terminal numbering on the rear case.

How are user inputs used on the meter?

The meter includes three programmable user inputs. These can be assigned to functions such as display hold, totalizer reset, batch accumulation, maximum or minimum reset, input tare, display selection, print request, or programme lock-out.

Can the front panel keys be programmed?

Yes. The front panel includes programmable function keys that can be assigned to selected meter functions. Some keys can also have secondary functions that activate after being held for a defined period.

What does an over-range display message indicate?

An over-range display message usually indicates that the measured signal is outside the configured input range or that the input wiring, scaling, or signal level should be checked. The meter can show different messages for signal high, signal low, or display value overflow conditions.

  • Displaying 4–20 mA process signals from transmitters in industrial control panels
  • Monitoring 0–10 V analogue signals from sensors and instrumentation
  • Providing local indication of pressure, flow, level, temperature or speed values
  • Scaling process inputs into engineering units for operator readability
  • Integrating flow or rate signals using the built-in totaliser function
  • Capturing minimum and maximum process readings for operational monitoring
  • Supporting alarm indication when used with compatible setpoint output option cards
  • Retransmitting measured values to other control equipment when fitted with an analogue output option card
  • Panel-mounted process indication in manufacturing, utilities and plant automation systems
  • Displaying transmitter-powered loop measurements using the 24 VDC excitation supply
  • Monitoring batch, tank, pump or line process values from standard industrial sensors
  • Replacing or standardising local analogue panel meters in process control applications

This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.

Delivery

  • Logistic partners UPS, FedEx and DHL
  • International delivery available
  • Premium nine hour delivery service available to anywhere in Europe
  • Same day dispatch from group stock

Warranty

All parts new or reconditioned are covered by EU Automation 12 month warranty

Returns

No hassle returns policy

Dedicated customer support team

Trade Credit

We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.

Payment options

We accept Bank transfers and the following methods of payment:

All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.

Services

Sourcing your part

Global supplier of quality automation and control components

Service Exchange

Dispose of your old unit by exchanging it for a working part.

Repair

A comprehensive repair service for faulty equipment.

Customer reviews

5 out of 5 stars steve

Got hold of Sime for a Carrier card for…


Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime

1 month ago

5 out of 5 stars Daniel

Excellent customer service...


Alex Bailey is my main point of contact at EU Automation...he is extremely friendly, has exceptional customer service skills and always offers great pricing & lead times.

3 months ago

5 out of 5 stars Jerry Schrink

Tom Higgins provided amazing service


Tom Higgins provided great prompt service. I contacted Tom by phone and within 10 minutes there was a quote in my in box. WOW Thank you Tom and Thank you EU Automation!

3 months ago

5 out of 5 stars Paulo Pereira

Excellent service and communication…


Excellent service and communication from Alex Bailey. He truly goes above and beyond to ensure his clients are 100% satisfied. The entire process was seamless, and his attention to detail made a huge difference. Highly recommended for anyone looking for amazing service!

3 months ago

5 out of 5 stars Gary

Tom Higgins did a great job at getting…


Tom Higgins did a great job at getting us the part we needed. He saw a concern with the part a verified before shipping.

4 months ago

5 out of 5 stars Lessle Smith

Thomas Higgins has gone above and…


Thomas Higgins has gone above and beyond to make things happen for my facility. His customer service and knowledge were an asset in helping me with my order and the logistics challenges!

4 months ago

Factory worker carrying automation parts box.

Our world, made possible by manufacturing. Manufacturing made possible by EU Automation.

Discover how we do our part to keep your production lines moving.

FAQs

View all FAQs

We're here when you need us