steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Panasonic |
| Part Number | DP-102 (DP102) |
| Product Type | Dual display digital pressure sensor for gas applications |
| Pressure Type | Gauge pressure |
| Rated Pressure Range | -0.100 to +1.000 MPa |
| Settable Pressure Range | -0.101 to +1.010 MPa |
| Displayable Pressure Range | -0.101 to +1.010 MPa |
| Selectable Pressure Units (typical) | MPa, kPa, kgf/cm², bar, psi |
| Applicable Fluid | Non-corrosive gas |
| Supply Voltage | 12 to 24 V DC ±10% (ripple P-P 10% or less) |
| Power Consumption | Normal operation: 720 mW or less (30 mA or less at 24 V DC); ECO modes: 480 mW or less (STD), 360 mW or less (FULL) |
| Comparative Outputs | 2 independent comparative outputs |
| Output Type (common configuration) | PNP open-collector transistor outputs |
| Maximum Load Current | 100 mA max. (per output) |
| Applied Voltage (Output Circuit) | 30 V DC or less (between output and +V) |
| Residual Voltage | 2 V or less (at 100 mA source current) |
| Output Operation | Normally Open / Normally Closed (selectable) |
| Output Modes | EASY mode / Hysteresis mode / Window comparator mode |
| Hysteresis | Minimum 1 digit (variable) |
| Repeatability | ±0.2% F.S. (within ±2 digits) |
| Response Time | Selectable: 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms |
| Display | Dual 4-digit, 3-colour LCD (main and sub display) |
| Display Refresh Rate | Selectable: 250 ms, 500 ms, 1,000 ms |
| Status Indication | Orange LED indicators for output operation |
| Protection Rating | IP40 |
| Ambient Operating Temperature | -10 to +50 °C (storage: -10 to +60 °C) |
| Ambient Humidity | 35 to 85% RH (no condensation or icing) |
| Pressure Withstandability | 1.5 MPa |
| Pressure Port (standard pressure port type) | M5 female thread + G 1/8 male thread |
| Materials | Enclosure: PBT (glass fibre reinforced); Display window: Acrylic; Pressure port: Stainless steel (SUS303); Mounting threaded part: Brass (nickel plated); Switch: Silicone rubber |
| Connection Method | Connector connection (CN-14A family compatible) |
| Cable Length (installation guidance) | Total cable length up to 100 m with suitable cable (up to 30 m when conforming to CE requirements) |
| Weight | Approx. 40 g (net) |
| Compliance | CE (EMC Directive), RoHS Directive |
It is a dual-display digital pressure sensor for monitoring gauge pressure in non-corrosive gas lines. It measures pressure and switches one or two transistor outputs when your set thresholds are reached.
This model is the high-pressure type in the DP-100 series, with a rated pressure range of -0.100 to +1.000 MPa (gauge). The displayable/settable range typically extends to about -0.101 to +1.010 MPa, depending on unit selection and variant.
It is intended for non-corrosive gases. It is not intended for liquids or corrosive gases.
Gauge pressure.
12 to 24 V DC (±10%), with ripple P-P 10% or less.
It provides comparative (switch) outputs using an open-collector transistor design. Output type depends on the exact variant (for example, some versions are PNP open-collector, others are NPN open-collector).
Yes. The comparative output operation can be set to N.O. or N.C. via the front keys (variant-dependent, but this is a standard feature in the DP-100 family including DP-102).
Common switching modes include EASY mode (simple ON/OFF), Hysteresis mode, and Window comparator mode, allowing single-threshold control or upper/lower window control.
The output response time is selectable. Typical settings include 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, and 5,000 ms.
The high-pressure type supports multiple selectable units, commonly including MPa, kPa, kgf/cm², bar, and psi (exact unit availability can vary by region/variant).
Yes. A zero-adjust (zero reset) function is provided to set the displayed value to zero when the pressure port is open to atmosphere, helping to compensate for minor offsets.
It uses a dual (main/sub) digital display so you can view the current pressure and a set value at the same time. The main display is a 3-colour type to improve status visibility during operation and setting.
Yes. An ECO mode is available to reduce power consumption by dimming the display or turning the display off, depending on the ECO setting.
Port style depends on the specific regional/variant configuration. Common configurations in this family include an M5 female thread combined with a parallel pipe thread adapter (such as G 1/8 for many European versions).
It is commonly supplied as a connector type using a 4-core connector cable assembly on many versions. Some variants use an M8 plug-in style connector. Confirm the exact connection style from the full model suffix on the label.
Typical protection rating for the DP-100 series body is IP40 (IEC), intended for use inside panels or protected locations.
Yes. A key lock function is available to prevent unintended setting changes during operation.
Common accessories in the DP-100 family include connector/cable assemblies, mounting brackets (including panel-mount options), and front protection covers. Accessory choice depends on how you plan to mount and cable the sensor.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.