steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | SICK |
| Part Number | 1052595 |
| Manufacturer Model | S30A-7111CL |
| Product Range | S3000 PROFINET IO Advanced |
| Product Type | Industrial laser scanner for area monitoring in automated equipment |
| Application Environment | Indoor |
| Network Operation | Operates exclusively within a networked control system (no local inputs/outputs) |
| Fieldbus / Industrial Network | PROFINET (with PROFIsafe profile) |
| PROFINET Device Features | PROFINET IO device with integrated 2-port real-time switch |
| Bus Connection Type | Fibre optic interface with 2 x SCRJ push-pull ports |
| Protective Field Range | 7 m |
| Warning Field Range | Up to 49 m (20 m at 20% reflectance) |
| Distance Measuring Range | Up to 49 m |
| Scan Angle | 190° |
| Angular Resolution | 0.5° or 0.25° (dependent on configuration) |
| Configurable Resolution | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm |
| Response Time | 60 ms (dependent on configuration) |
| Simultaneously Monitored Protective Fields | 2 |
| Field Set Type | Dual field sets |
| Number of Field Sets | 4 |
| Total Fields | 8 |
| Monitoring Cases | 4 |
| Multiple Evaluation (Configurable) | 2 to 16 |
| Configuration & Diagnostics Interface | RS-232 |
| Supply Voltage | 24 V DC (16.8 V DC to 28.8 V DC) |
| Current Consumption | ≤ 0.8 A (at 24 V DC, without output load) |
| Enclosure Rating | IP65 |
| Operating Temperature | -10 °C to +50 °C |
| Storage Temperature | -25 °C to +50 °C |
| Dimensions (L × H × W) | 155 mm × 185 mm × 160 mm |
| Weight | 3.3 kg |
| Housing Material | Aluminium die-cast |
| Housing Colour | RAL 1021 (rapeseed yellow) |
| Front Screen Material | Polycarbonate |
| Front Screen Surface | Scratch-resistant coated outer surface |
| Light Source | Pulsed laser diode |
| Wavelength | 905 nm |
| Laser Classification | Class 1 (IEC 60825-1 / 21 CFR 1040.10 and 1040.11) |
| Mounting Points | 4 × M6 × 8 and 4 × M8 × 9 (per device drawing) |
This device monitors configurable protective and warning zones using a 2D laser scan. It is commonly used to detect the presence of people or objects within defined areas and communicate the status to a controller over an industrial network.
It integrates into a PROFINET network with a PROFIsafe profile, operating as a PROFINET IO device with an integrated 2-port real-time switch.
No. This PROFINET IO variant has no local inputs/outputs and is intended to be used exclusively within a networked system with an appropriate controller.
This version uses fibre optic PROFINET (100Base-FX) via two SCRJ push-pull sockets.
The protective field range is up to 7 m. The warning field range can be up to 49 m (typically up to 20 m at 20% remission).
It provides a scanning angle of 190°.
Selectable resolutions include 30 mm, 40 mm, 50 mm, 70 mm, and 150 mm (configurable).
The response time is 60 ms, depending on the basic response time settings and evaluation parameters.
It supports dual field sets with 4 field set areas, 8 fields in total, and up to 4 monitoring tasks, with up to 2 protective fields monitored simultaneously.
It operates on 24 V DC (16.8 V DC to 28.8 V DC). Current consumption is up to 0.8 A at 24 V DC without output load.
A system plug is required for operation and must be ordered separately. The integrated configuration memory is located in the system plug; for example, one compatible option is the SX1A-A0000L (the scanner itself is the sensor without the system plug).
The enclosure is rated IP65.
Operating ambient temperature is −10 °C to +50 °C. Storage temperature is −25 °C to +50 °C.
Approximate dimensions are 155 mm x 185 mm x 160 mm, and the weight is about 3.3 kg.
The housing is aluminium die-cast (RAL 1021 colour). The front screen is polycarbonate with a scratch-resistant coated outer surface.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Pembekal global untuk komponen automasi dan kawalan berkualiti
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.