steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 140ERT85410 |
| Manufacturer | Schneider |
| Category | PLC Systems |
| Family | Modicon Quantum |
| Product Type | Multifunction Time Stamp Input Module |
| Number of Terminals | ≤ 40 |
| Function | Status logging counting 500 Hz, Status monitoring on discrete inputs, Time and date stamped event logging |
| Time Synchronisation Protocol | DCF77 |
| Product Compatibility | Unity Pro, Concept |
| Group of Channels | 2 groups of 16 inputs for process input |
| Discrete Input Number | 32 discrete inputs at 24...125 V for process input, 1 discrete input at 24 V for clock signal input |
| Switching Voltage | 60 V at 2.5 mA for process input, 48 V at 2.5 mA for process input, 24 V at 6 mA for process input, 125 V at 1 mA for process input |
| Power Consumption | ≤ 7.5 W for process input |
| Insulation | By optocoupler for clock signal input, By optocoupler between group of channels |
| Anti-Bounce Filtering | Configurable from 0 to 255 ms |
| Input State | Inversion configurable |
| Acquisition Time | 1 ms for clock signal input |
| Input Current | 5 mA for clock signal input |
| Electrical Connection | Unshielded cable, cable length: ≤ 400 m for process input; Shielded cable, cable length: ≤ 600 m for process input |
| Connections - Terminals | Screw terminal block |
| Local Signalling | 32 LEDs for status of inputs (1 to 32), 1 LED red for fault (F), 1 LED green for self-test OK, module ready (R), 1 LED green for communication on the bus (Active) |
| Current Consumption | 300 mA at 5 V DC bus, 3 mA at 24...125 V DC external power supply per group of channel, 0.07 mA at 24 V DC 140XCP90000 module |
| Module Format | Standard |
| Product Weight | 0.45 kg |
| Resistance to Electrostatic Discharge | 8 kV on air conforming to IEC 801-2, 4 kV contact conforming to IEC 801-2 |
| Resistance to Electromagnetic Fields | 10 V/m at 80...2000 MHz conforming to IEC 801-3 |
| Ambient Air Temperature for Operation | 0...60 °C |
| Ambient Air Temperature for Storage | -40...85 °C |
| Relative Humidity | 95% without condensation |
| Operating Altitude | ≤ 5000 m |
| Protective Treatment | TC |
| Standards | HazLoc, UL 508 |
| Product Certifications | CSA Class 1 Division 2, C-Tick, GOST, LR, UL, Merchant Navy |
| Sustainable Offer Status | Green Premium product |
| RoHS Compliance | Compliant since 0901 |
| REACh Compliance | Reference not containing SVHC above the threshold |
| Product Environmental Profile | Available |
| Product End of Life Instructions | Need no specific recycling operations |
The primary function of the Schneider 140ERT85410 module is to provide multifunction input capabilities, including status logging, status monitoring on discrete inputs, and time and date stamped event logging.
This module supports 32 discrete inputs for process input at 24...125 V and 1 discrete input for clock signal input at 24 V.
The power consumption for the Schneider 140ERT85410 module is less than or equal to 7.5 W for process input.
The operating temperature range for the Schneider 140ERT85410 module is 0 to 60 °C.
The maximum operating altitude for the Schneider 140ERT85410 module is 5000 meters.
For process input, unshielded cables with a length of up to 400 meters and shielded cables with a length of up to 600 meters are recommended.
The Schneider 140ERT85410 module has a standard module format with a weight of 0.45 kg.
The Schneider 140ERT85410 module is certified by CSA Class 1 Division 2, C-Tick, GOST, and LR.
The Schneider 140ERT85410 module has a resistance to electrostatic discharge of 8 kV on air and 4 kV on contact, conforming to IEC 801-2.
The Schneider 140ERT85410 module uses the DCF77 time synchronisation protocol.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Pembekal global untuk komponen automasi dan kawalan berkualiti
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.