steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Eurotherm |
| Part Number | 2132I (also referenced as 2132i) |
| Product Type | Temperature/process indicator and alarm unit for panel mounting |
| Part Description | Compact Eurotherm panel indicator with a bright 4‑digit green LED display for monitoring temperature or scaled process signals, with configurable internal alarm functions and optional relay/logic alarm outputs depending on unit configuration. |
| Display | 4‑digit green LED, 10 mm character height |
| Supply Voltage (Low Voltage Variant) | 24 V AC/DC nominal (operating range 20–29 V AC/DC, DC to 62 Hz) |
| Power Consumption | 5 W maximum |
| Sensor / Input Types (Typical) | Thermocouples (e.g., J, K, T, L, N, R, S, B, E and additional custom types), Pt100 RTD, and scalable linear process inputs (mV/mA/voltage with adapter as applicable) |
| Linear Input Ranges (Scalable) | mV: -9.99 to +80 mV; Current: 0–20 mA or 4–20 mA; Voltage: 0–10 V DC (input adapter required) |
| Alarm Capability | Three internal (“soft”) alarms; can be assigned to fitted outputs where available |
| Relay Output Rating (When Fitted) | Isolated relay output: up to 264 V AC, 2 A resistive (minimum 12 V DC, 100 mA) |
| Logic I/O (When Fitted) | 9 V DC logic output at approx. 12–18 mA; can be configured as alarm output or alarm acknowledge input (non-isolated from sensor input) |
| Calibration Accuracy | ±1 °C or ±0.25% of reading (whichever is greater) |
| Cold Junction Compensation (TC Inputs) | Integrated cold junction compensation with high ambient change rejection |
| Input Filtering | Adjustable from Off to 999.9 seconds |
| Operating Ambient Temperature | 0 to 55 °C |
| Operating Humidity | 5 to 95% RH, non-condensing |
| Storage Temperature | -30 to +75 °C |
| Front Panel Sealing | IP65 (EN 60529) / NEMA 4X (front face when correctly panel mounted) |
| Panel Cut-out (2132i Format) | 22.2 mm (−0.0/+0.3) × 45 mm (−0.0/+0.6) |
| Front Bezel Size (2132i Format) | 48 mm (H) × 103 mm (W) |
| Connection / Wiring | Screw terminals; accepts 0.5 to 1.5 mm² conductors (16–22 AWG) |
| Compliance (General) | Designed to meet industrial EMC and electrical safety standards (e.g., EN 61010; industrial EMC emissions/immunity standards as applicable) |
| Commodity Code | 903210 |
It is a compact temperature/process indicator that measures a sensor or analogue signal and shows the process value on a 4-digit LED display. Depending on configuration, it can also provide alarm indication and physical alarm outputs.
It uses a 4-digit green LED display with 10 mm high characters for clear visibility on a panel door.
This version is the low-voltage supply type and is designed for 24 V AC/DC operation (typically within the 20–29 V range). Power consumption is up to 5 W.
It supports common thermocouples (such as J, K, T, L, N, R, S, B and others), Pt100 RTD input, and scalable linear process inputs (mV, mA; and 0–10 V with the appropriate input adaptor). The exact input fitted is determined by the side label coding/configuration.
Yes. When configured for a linear current input, it can display scalable values for 4–20 mA (and 0–20 mA). Scaling allows you to map the input signal to engineering units shown on the display.
It has three internal alarm setpoints (often referred to as “soft” alarms). These can trigger front-panel indication and can be assigned to the relay output and/or the logic output (if fitted).
Common alarm behaviours include high and low alarms, plus deviation-style alarms (such as deviation band, deviation high, and deviation low), depending on configuration settings.
Alarms can be acknowledged using a key combination on the front keypad, and the OP indicators change from flashing (new alarm) to steady (acknowledged but still true) when applicable.
Depending on the build, it may include an isolated alarm relay output and a logic I/O point. The logic I/O can be set as an alarm output or as an alarm acknowledge/reset input (when fitted).
The relay output (isolated) is rated up to 264 Vac at 2 A resistive (minimum 12 Vdc at 100 mA). The logic I/O provides approximately 9 Vdc at around 12–18 mA and is not isolated from the sensor input.
Typical calibration accuracy is ±1 °C or ±0.25% of reading (whichever is greater), subject to correct sensor selection, wiring practice, and stable installation conditions.
Yes. An input filter time constant can be set from OFF up to 999.9 seconds to help smooth fluctuating readings where required.
Yes. User calibration options allow a fixed offset across the range and also a two-point adjustment method to align the displayed value to reference points.
For the 2132i size, the typical panel cut-out is 22.2 mm by 45 mm. The unit is designed for panel mounting using retaining clips.
When correctly installed in a suitable panel cut-out with the sealing maintained, the front panel is rated to IP65 (and NEMA 4X equivalent).
The screw terminals typically accept copper conductors in the 0.5 to 1.5 mm² range (approximately 16 to 22 AWG).
No. The logic I/O is electrically connected to the sensor input, which is important to consider when planning wiring, earthing, and how the logic point is interfaced to other equipment.
Yes. Display units can be configured for Celsius, Fahrenheit, Kelvin, or no units for linear process inputs, depending on how the input is set up.
Check the side label coding on the instrument body to identify the configured supply type, input type, and whether relay/logic I/O options are fitted. This is the most reliable way to match a unit to an application; you may also reference it internally as Eurotherm 2132i.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Pembekal global untuk komponen automasi dan kawalan berkualiti
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.