steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | ABB |
| Part Number | SK1-11 |
| Alternative Part Number | SK111 |
| Product ID | 1SAM201903R1001 |
| Product Type | Signalling contact for manual motor starters |
| Contact Configuration | 1 normally open (NO) and 1 normally closed (NC) contact |
| Function | Indicates when the connected manual motor starter has tripped due to a short circuit, overload or electrical release |
| Reset Method | Manual reset using the protruding orange button |
| Mounting Position | Right-hand side of the manual motor starter |
| Compatible Devices | ABB MS116, MS132, MO132, MS165 and MO165 manual motor starters |
| Terminal Type | Screw terminals |
| Rated Operational Voltage | Up to 690 V AC and 600 V DC |
| AC-15 Rated Current | 6 A at 24 V; 4 A at 240 V; 3 A at 380–400 V; 1 A at 690 V |
| DC-13 Rated Current | 2 A at 24 V; 0.55 A at 125 V; 0.27 A at 250 V; 0.15 A at 440–600 V |
| Rated Insulation Voltage | 690 V |
| Rated Impulse Withstand Voltage | 6 kV |
| UL/CSA Maximum Operating Voltage | 600 V AC |
| UL/CSA Contact Rating | B600 and Q600 |
| Degree of Protection | IP20 |
| Electrical Durability | 100,000 operating cycles |
| Mechanical Durability | 100,000 operating cycles |
| Flexible Conductor Capacity | 1 or 2 conductors, 0.75–1.5 mm² |
| Rigid Conductor Capacity | 1 or 2 conductors, 1–1.5 mm² |
| UL/CSA Conductor Capacity | 1 or 2 flexible or stranded conductors, 16–14 AWG |
| Tightening Torque | 0.8–1.2 N·m |
| UL/CSA Tightening Torque | 7 in·lb |
| Wire Stripping Length | 8 mm |
| Recommended Screwdriver | Pozidriv 2 for M3 terminal screws |
| Operating Temperature | -25 to +60 °C |
| Storage Temperature | -50 to +80 °C |
| Shock Resistance | 25g, 11 ms pulse, in accordance with IEC 60068-2-27 |
| Vibration Resistance | 5g at 3–150 Hz |
| Dimensions | 9 mm wide × 90 mm high × 78.5 mm deep |
| Net Weight | 0.035 kg |
| Standards | IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, UL 60947-1, UL 60947-4-1 and CSA C22.2 No. 14 |
| EAN | 4013614320392 |
It provides an electrical indication when a compatible manual motor starter trips. This allows the trip condition to be communicated to a control circuit, indicator lamp or monitoring device.
The SK1-11 is designed for use with ABB MS116, MS132, MO132, MS165 and MO165 manual motor starters.
It provides one normally open contact and one normally closed contact, commonly described as a 1 NO + 1 NC contact arrangement.
It can indicate a trip caused by a short circuit, overload or operation of a compatible electrical release, such as an AA1 shunt trip or UA1 undervoltage release.
It is mounted on the right-hand side of the compatible manual motor starter.
No. After a trip, the contact positions must be reset manually by pressing the protruding orange button on the device.
The unit uses screw terminals for connecting the auxiliary circuit conductors.
The AC-15 ratings are 6 A at 24 V, 4 A at 240 V, 3 A at 380–400 V and 1 A at 690 V.
The DC-13 ratings are 2 A at 24 V, 0.55 A at 125 V, 0.27 A at 250 V and 0.15 A at 440 V or 600 V.
The rated insulation voltage is 690 V, while the auxiliary circuit has a rated impulse withstand voltage of 6 kV.
The terminals accept flexible conductors from 0.75 to 1.5 mm², including conductors with ferrules, and rigid conductors from 1 to 1.5 mm².
The specified tightening torque for the auxiliary circuit terminals is 0.8 to 1.2 N·m. The recommended wire stripping length is 8 mm.
The contact measures approximately 9 mm wide, 90 mm high and 78.5 mm deep. Its net weight is approximately 0.035 kg.
The device has an IP20 degree of protection when installed in the intended configuration.
It is specified for operation in ambient temperatures from -25°C to +60°C and for storage from -50°C to +80°C.
The specified electrical durability and mechanical durability are each 100,000 operating cycles under the stated conditions.
The product is specified in accordance with standards including IEC/EN 60947-1, IEC/EN 60947-5-1, UL 508, UL 60947-1, UL 60947-4-1 and CSA 22.2 No. 14.
This device is specifically intended to signal a trip condition. An auxiliary contact from the HK or HKF range is generally used when the application requires indication of the normal ON or OFF position.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.