steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | RM35UB3N30 |
| Manufacturer | Schneider |
| Product Type | Control Relay |
| Application | For 3-phase supply monitoring |
| Relay Name | RM35UB3 |
| Monitored Parameters | Absence of neutral, overvoltage and undervoltage between phases and neutral |
| Time Delay Type | Adjustable 0.3 to 30 seconds, ±10% on threshold crossing |
| Switching Capacity | 1250 VA |
| Minimum Switching Current | 10 mA at 5 V DC |
| Maximum Switching Current | 5 A AC/DC |
| Power Consumption | ≤ 3.9 VA AC |
| Measurement Range | 114 to 329 V AC, 50/60 Hz |
| Utilisation Category | AC-12, AC-13, AC-14, AC-15, DC-12, DC-13, DC-14 according to IEC 60947-5-1 |
| Contact Type and Composition | 2 C/O (Changeover) contacts |
| Reset Time | 1500 ms for time delay |
| Maximum Switching Voltage | 250 V AC/DC |
| Rated Supply Voltage | 120 to 277 V AC, 50/60 Hz ±10% |
| Supply Voltage Limits | 114 to 329 V AC |
| Voltage Detection Threshold | 114 V |
| Control Circuit Frequency | 50 to 60 Hz ±15% |
| Output Contacts | 1 C/O + 1 C/O, 1 per threshold |
| Nominal Output Current | 5 A |
| Measuring Cycle | ≤ 150 ms measurement cycle as true RMS value |
| Hysteresis | 2% |
| Run Up Delay at Power Up | ≤ 650 ms |
| Measurement Accuracy | ±10% of the full scale value |
| Repeat Accuracy | ±0.5% for input and measurement circuit, ±1% for time delay |
| Measurement Error | <1% over the whole range with voltage variation |
| Response Time | <200 ms in the event of a fault |
| Quality Labels | CE |
| Overvoltage Category | III according to IEC 60664-1 |
| Insulation Resistance | > 500 MOhm at 500 V DC according to IEC 60255-5 and IEC 60664-1 |
| Rated Insulation Voltage | 400 V according to IEC 60664-1 |
| Operating Position | Any position without derating |
| Connections - Terminals | Screw terminals for various wire types and sizes |
| Tightening Torque | 0.6 to 1 N.m according to IEC 60947-1 |
| Housing Material | Self-extinguishing plastic |
| Local Signalling | LED indicators for power ON and relay ON |
| Mounting Support | 35 mm symmetrical DIN rail according to IEC 60715 |
| Electrical Durability | 10000 cycles |
| Mechanical Durability | 30000000 cycles |
| Operating Rate | ≤ 360 operations/hour under full load |
| Safety Reliability Data | MTTFd = 502.2 years, B10d = 470000 |
| Width | 35 mm |
| Net Weight | 0.08 kg |
| Functionality | Overvoltage and undervoltage detection |
| Compatibility Code | RM3 |
| Electromagnetic Compatibility | Emission standards for industrial, residential, commercial, and light-industrial environments |
| Standards | EN/IEC 60255-1 |
| Product Certifications | UL, C-Tick, GL, CSA, GOST |
| Directives | 89/336/EEC - electromagnetic compatibility, 73/23/EEC - low voltage directive |
| Ambient Air Temperature | For storage: -40 to 70 °C, for operation: -20 to 50 °C |
| Relative Humidity | 95% at 55 °C according to IEC 60068-2-30 |
| Vibration Resistance | 0.35 mm (f = 5 to 57.6 Hz), 1 gn (f = 57.6 to 150 Hz) according to IEC standards |
| Shock Resistance | 5 gn according to IEC 60068-2-27 |
| IP Degree of Protection | IP20 (terminals), IP30 (casing) according to IEC 60529 |
| Pollution Degree | 3 according to IEC 60664-1 |
| Dielectric Test Voltage | 2 kV AC 50 Hz, 1 min |
| Non-dissipating Shock Wave | 4 kV |
The control relay operates within a voltage range of 114 to 329 V AC, suitable for various 3-phase supply applications.
Yes, the time delay is adjustable from 0.3 to 30 seconds, with a tolerance of 0 + 10%, allowing for precise control in your application.
This relay is equipped with 2 C/O (changeover) contacts, providing flexibility for switching between circuits.
The maximum switching current for the RM35UB3N30 is 5 A AC/DC, which is suitable for a wide range of control applications.
The relay is designed for DIN rail mounting, making it easy to install in standard enclosures.
The hysteresis for this relay is set at 2%, which helps to prevent unnecessary switching due to minor voltage fluctuations.
The response time of the relay is less than 200 ms in the event of a fault, ensuring quick action to protect your system.
The insulation resistance of the relay is greater than 500 MOhm at 500 V DC, conforming to IEC standards for electrical safety.
The dimensions of the relay are 72 x 35 x 90 mm, making it compact and suitable for use in space-constrained environments.
The relay falls under several utilisation categories, including AC-12, AC-13, AC-14, AC-15, DC-12, DC-13, and DC-14, conforming to IEC 60947-5-1.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.