steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part number | C10N4 |
| Manufacturer | Schneider Electric |
| Product type | Circuit breaker basic frame |
| Range | ComPacT new generation |
| Product name | ComPacT NSX new generation |
| Device short name | NSX100N |
| Frame rating | 100 A |
| Configuration | Basic frame without trip unit |
| Application | Power distribution |
| Number of poles | 4P |
| Neutral position | Left |
| Rated current (In) | 100 A at 40 °C |
| Rated operational voltage (Ue) | Up to 690 V AC |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes, in accordance with EN/IEC 60947-2 |
| Utilisation category | Category A |
| Performance level | N, 50 kA at 415 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) | 90 kA at 220/240 V AC; 50 kA at 380/415 V AC; 50 kA at 440 V AC; 36 kA at 500 V AC; 35 kA at 525 V AC; 10 kA at 660/690 V AC (IEC 60947-2) |
| UL breaking capacity | 85 kA at 240 V AC; 50 kA at 480 V AC; 10 kA at 600 V AC |
| Rated service short-circuit breaking capacity (Ics) | 90 kA at 220/240 V AC; 50 kA at 380/415 V AC; 50 kA at 440 V AC; 36 kA at 500 V AC; 35 kA at 525 V AC; 10 kA at 660/690 V AC |
| Rated insulation voltage (Ui) | 800 V AC |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Control type | Toggle |
| Mounting mode | Fixed |
| Mounting support | Backplate |
| Connection orientation | Front connection, top and bottom |
| Connection pitch | 35 mm |
| Protection type | Without protection |
| Mechanical durability | 50,000 cycles |
| Electrical durability | 10,000 cycles at 690 V AC In; 20,000 cycles at 690 V AC In/2; 30,000 cycles at 440 V AC In; 50,000 cycles at 440 V AC In/2 |
| Width | 140 mm |
| Height | 161 mm |
| Depth | 86 mm |
| IP rating | IP40 |
| IK rating | IK07 |
| Pollution degree | 3 |
| Operating temperature | -25 to +70 °C |
| Storage temperature | -50 to +85 °C |
| Standards | EN/IEC 60947-2, UL 60947-4-1 |
| Product certifications | CSA, UL |
| RoHS status | Compliant with exemptions |
| Mercury free | Yes |
This is a fixed-mount circuit breaker basic frame designed for power distribution applications. It is a 4-pole unit in the ComPacT NSX100N range with a 100 A frame rating, and it is supplied without a trip unit.
No. This basic frame is supplied without a trip unit, so it does not provide overcurrent protection on its own until a compatible trip unit is fitted.
It has 4 poles, making it suitable for applications where four-pole switching or isolation is required. The neutral position is on the left.
The frame is rated at 100 A at 40°C and is intended for AC networks at 50/60 Hz. Its rated operational voltage is up to 690 V AC in accordance with IEC 60947-2.
This frame offers high breaking performance for its class. For the C10N4, the rated ultimate short-circuit breaking capacity reaches 50 kA at 380/415 V AC and 440 V AC, 36 kA at 500 V AC, 35 kA at 525 V AC, 10 kA at 660/690 V AC, and 90 kA at 220/240 V AC under IEC 60947-2.
Yes. The unit is suitable for isolation in accordance with EN/IEC 60947-2, which makes it appropriate for installations where safe disconnection is required as part of the design.
This is a fixed-mount unit intended for backplate installation. It has front connections on both the upper and lower sides, with a connection pitch of 35 mm.
The unit measures 140 mm wide, 161 mm high and 86 mm deep. These dimensions can be useful when checking panel space or planning a replacement.
It has an IP40 degree of protection and an IK07 impact rating. The pollution degree is 3, and the operating temperature range is from -25°C to 70°C, with storage from -50°C to 85°C.
The device is designed in line with EN/IEC 60947-2 and carries UL and CSA product certifications. This helps make it a suitable option for a wide range of industrial and commercial panel applications.
The mechanical durability is rated at 50,000 operating cycles. Electrical durability depends on the operating conditions, with ratings including 10,000 cycles at 690 V AC at full rated current and up to 50,000 cycles at 440 V AC at half rated current.
Key points to check include the required number of poles, frame size, voltage rating, breaking capacity, mounting arrangement, connection layout and compatibility with the intended trip unit. As this is a basic frame only, confirming the correct trip unit arrangement is especially important.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.