steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Part Number | 3RF2030-1AA04 |
| Alternative Part Number | 3RF20301AA04 |
| Product Range | SIRIUS 3RF2 |
| Product Type | Solid-state semiconductor relay |
| Relay Design | Single-phase |
| Switching Function | Zero-point switching |
| Main Circuit Poles | 1 pole |
| Main Contact Configuration | 1 normally open contact |
| Rated Operating Voltage | 48 to 460 V AC at 50/60 Hz |
| Operating Voltage Range | 40 to 506 V AC at 50/60 Hz |
| Rated Operational Current | 30 A |
| Minimum Operational Current | 500 mA |
| Rated Control Voltage | 24 V DC nominal control input |
| Control Voltage Range | 15 to 24 V DC |
| Rated Control Supply Voltage | 30 V DC |
| Control Current | 13 mA at minimum control voltage; 15 mA at rated DC value |
| Switch-On Delay | 1 ms plus maximum one half-wave |
| Switch-Off Delay | 1 ms plus maximum one half-wave |
| Rated Frequency | 50 to 60 Hz |
| Frequency Tolerance | 10% symmetrical tolerance |
| Rated Insulation Voltage | 600 V |
| Maximum Thyristor Blocking Voltage | 1,200 V |
| Maximum Voltage Rise Rate | 500 V/µs |
| Thyristor Reverse Current | 10 mA |
| Surge Current Resistance | 300 A |
| I²t Value | 450 A²s maximum |
| Power Loss at Rated Current | 44.2 W in hot operating state |
| Typical No-Load Power Loss | 0.4 W |
| Derating Temperature | 40 °C |
| Terminal Type | Screw terminals for main, auxiliary and control circuits |
| Main Terminal Thread | M4 |
| Control Terminal Thread | M3 |
| Main Contact Conductor Size | Solid or stranded: 1.5 to 6 mm²; finely stranded with ferrule: 1 to 10 mm² |
| Control Contact Conductor Size | 0.5 to 2.5 mm² for single conductor connection |
| Main Contact AWG Range | AWG 14 to 10 |
| Control Contact AWG Range | AWG 20 to 12 |
| Main Contact Tightening Torque | 2 to 2.5 N·m |
| Control Contact Tightening Torque | 0.5 to 0.6 N·m |
| Main Cable Stripping Length | 10 mm |
| Control Cable Stripping Length | 7 mm |
| Mounting Method | Screw fixing |
| Side-by-Side Mounting | Suitable for side-by-side installation |
| Fixing Screw Tightening Torque | 1.5 N·m maximum |
| Dimensions | 58 mm height x 45 mm width x 48 mm depth |
| Front Protection Rating | IP20 according to IEC 60529 |
| Touch Protection | Finger-safe from vertical contact at the front |
| Shock Resistance | 15 g for 11 ms according to IEC 60068-2-27 |
| Vibration Resistance | 2 g according to IEC 60068-2-6 |
| Operating Temperature | -25 to +60 °C |
| Storage Temperature | -55 to +80 °C |
| Maximum Installation Altitude | 1,000 m above sea level |
| EMC Burst Immunity | 2 kV / 5 kHz according to IEC 61000-4-4 |
| EMC Surge Immunity | 2 kV conductor-to-earth and 1 kV conductor-to-conductor according to IEC 61000-4-5 |
| Electrostatic Discharge Rating | 4 kV contact discharge and 8 kV air discharge according to IEC 61000-4-2 |
| HF Emissions Classification | Conducted emissions Class A for industrial environments; field-bound emissions Class B |
| Reference Code | Q according to IEC 81346-2 |
| Commodity Code | 853649 |
It is a single-phase solid-state semiconductor relay from the SIRIUS 3RF2 range, designed for switching AC loads using a DC control signal. It uses zero-point switching, making it suitable for frequent switching of resistive loads.
The main AC circuit is rated for 48 to 460 V at 50 or 60 Hz. Its operating range extends from 40 to 506 V AC, depending on frequency.
The relay is rated for 30 A, including AC-51 applications and UL 508-rated operation. The minimum operating current is 500 mA.
The control input is DC. It is rated at 30 V DC and operates across a 15 to 24 V DC control supply range, with a typical rated control current of 15 mA.
Yes. The relay has a zero-point switching function, meaning it switches close to the AC waveform zero crossing to reduce electrical stress and interference when controlling suitable loads.
The unit measures 58 mm high, 45 mm wide and 48 mm deep. Its 45 mm width makes it a compact single-phase relay for panel mounting.
It is designed for screw fixing and can be mounted side by side with compatible devices. The maximum tightening torque for the fixing screw is 1.5 N·m.
The relay uses screw-type terminals for both the main current circuit and the auxiliary/control circuit. Main contacts use M4 screws, while auxiliary and control contacts use M3 screws.
For the main contacts, solid conductors from 1.5 to 6 mm² can be used. Finely stranded conductors with core end processing can be used from 1 to 10 mm², depending on the connection arrangement.
The main contact screw terminals require 2 to 2.5 N·m. The auxiliary and control terminals require 0.5 to 0.6 N·m.
The recommended stripping length is 10 mm for the main contacts and 7 mm for the auxiliary and control contacts.
The relay is rated for operation from -25 °C to +60 °C and storage from -55 °C to +80 °C. Derating begins at 40 °C.
The front of the device is rated IP20 according to IEC 60529. It is finger-safe for vertical contact from the front.
The rated insulation voltage is 600 V, making the relay suitable for many industrial AC switching applications within its rated limits.
At rated AC current in a hot operating state, the power loss is 44.2 W. This should be considered when designing enclosure ventilation and heat dissipation.
Specified protective fuse options include Siemens fuse references such as 3NE1815-0, 5SE1325, 3NE8003-1, 3NC1025, 3NC1430, 3NC2232, 3NA6803, 3NW6101-1, 5SB251 and 5SE2313-2A, depending on fuse style and protection category.
The relay has a rated surge current resistance of 300 A and a maximum I²t value of 450 A²s.
The ON-delay time is 1 ms plus a maximum of one half-wave. The OFF-delay time is also 1 ms plus a maximum of one half-wave.
This type of relay is commonly used for frequent switching of single-phase AC loads such as heaters, resistive loads, industrial process equipment and control cabinet applications where silent, wear-free switching is useful.
No. This relay has no normally open, normally closed or changeover auxiliary contacts. It is a single-pole main switching device with a DC control input.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.