Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
4 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 3LD3148-0TK53 |
| Manufacturer | Siemens |
| Product Brand Name | SENTRON |
| Product Designation | Switch Disconnector |
| Design of the Product | EMERGENCY-STOP switch |
| Number of Poles | 3 |
| Mechanical Service Life | 100,000 operating cycles |
| Electrical Endurance | 6,000 operating cycles at AC-23 A at 690 V |
| Operating Frequency | Maximum 50 operations per hour |
| Degree of Pollution | 3 |
| Insulation Voltage | 690 V |
| Surge Voltage Resistance | 6 kV |
| Operating Voltage | 690 V AC |
| Protection Class | IP65 |
| NEMA Rating | 1, 3R, 4X, 12 |
| Power Loss | 1.1 W per pole in hot operating state |
| Operational Current | 25 A at AC-21 at 690 V |
| Rated Operating Capacity | 9.0 kW at AC-23 A at 400 V |
| Type of Switch | Floor mounting with door coupling |
| Actuating Element | Short rotary knob, red/yellow |
| Dimensions | Height: 60 mm, Width: 36 mm, Depth: 380 mm |
| Net Weight | 300 g |
| Ambient Temperature | -25 °C to 55 °C during operation |
| Mounting Method | Built-in unit fixed-mounted version, front mounting with central attachment, rail mounting |
| Short Circuit Protection | Required fuse gL/gG: 25 A for main circuit, 10 A for auxiliary switch |
| Conditional Short-Circuit Current | 10 kA at 440 V by gG fuse, 6 kA at 690 V by gG fuse |
| Let-Through Current | Maximum 3.5 kA at 240 V and 440 V, permissible 4 kA at 690 V for combination switch + gG fuse |
| I2t Value | Maximum 4 kA².s at 240 V, 440 V, and 690 V for combination switch + gG fuse |
| Type of Electrical Connection | Box terminal for main current circuit and auxiliary contacts |
| Connectable Conductor Cross-Sections | Solid: 1x (2.5 to 16 mm²), Finely stranded with core end processing: 1x (2.5...16 mm²), Stranded: 1x (2.5 to 16 mm²) |
| Auxiliary Contacts | Solid: 2x (0.75 ... 2.5 mm²), 1x 4 mm²; Finely stranded with core end processing: 2x (0.75 ... 1.5 mm²), 1x 2.5 mm²; Stranded: 2x (0.75 ... 2.5 mm²), 1x 4 mm² |
| Special Product Feature | Can be locked in zero position |
| Product Extension | Optional motor drive: No, Optional voltage trigger: No |
| Hasp Thickness | 4 ... 8 mm |
| Number of Bracket Locks | Maximum 3 |
The primary function of the Siemens 3LD3148-0TK53 load disconnector is to safely disconnect electrical circuits, ensuring that maintenance and repair work can be carried out without risk of electric shock.
Yes, the Siemens 3LD3148-0TK53 is designed to function as an emergency stop switch, providing a reliable means to quickly disconnect power in emergency situations.
The Siemens 3LD3148-0TK53 load disconnector has a rated operational current of 25 A.
This load disconnector offers a protection class of IP65, making it suitable for use in environments where it may be exposed to dust and water.
Yes, the Siemens 3LD3148-0TK53 is suitable for use as a main switch, providing a reliable means to control the power supply to electrical circuits.
The mechanical service life of the Siemens 3LD3148-0TK53 load disconnector is typically 100,000 operating cycles.
The Siemens 3LD3148-0TK53 supports floor mounting with door coupling and can be mounted using a central hole.
The maximum operating voltage for the Siemens 3LD3148-0TK53 load disconnector is 690 V AC.
Yes, this load disconnector can be locked in the off position, providing an additional safety feature to prevent accidental reconnection.
The rated power loss per pole for the Siemens 3LD3148-0TK53 is 1.1 W in a hot operating state.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.