steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | VBF1GE |
| Product Range | TeSys |
| Series / Product Name | TeSys VARIO |
| Product Type | Enclosed switch disconnector (main switch disconnector) |
| Description | Schneider Electric TeSys VARIO VBF1GE is an IP65 enclosed 3‑pole switch disconnector with a black rotary handle, designed for dependable ON/OFF isolation of three‑phase circuits in industrial control panels and machinery. |
| Poles | 3P |
| Handle / Control Type | Rotary handle |
| Handle Colour | Black |
| Handle Front Plate Colour | Black |
| Switch Positions / Marking | 0 – 1 |
| Padlocking Provision | 1 to 3 padlocks (shackle diameter 4–8 mm) |
| Rated Operational Voltage (Ue) | 690 V AC |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Conventional Enclosed Thermal Current (Ithe) | 25 A |
| Rated Operational Current (Ie) | 21.8 A (AC-23A at 400 V) |
| Rated Operational Power | 11 kW at 400 V (AC-23); 7.5 kW at 400 V (AC-3) |
| Intermittent Duty Class | 30 |
| Making Capacity (I rms) | 320 A at 400 V (AC-21A / AC-22A / AC-23A) |
| Short-Circuit Making Capacity (Icm) | 1 kA at 400 V (Ipeak) |
| Short-Time Withstand Current (Icw) | 384 A at 400 V for 1 s |
| Conditional Short-Circuit Current | 10 kA at 400 V with associated fuse 35 A (aM or gG) |
| Breaking Capacity | 250 A at 400 V (AC-21A / AC-22A / AC-23A) |
| Suitability for Isolation | Yes |
| Degree of Protection | IP65 (IEC 60529) |
| Standards | IEC 60204; IEC 60947-4-1 |
| Ambient Operating Temperature | -20…50 °C |
| Connections / Terminals | Screw clamp terminals |
| Conductor Capacity (Solid) | Up to 10 mm² |
| Conductor Capacity (Flexible, with cable end) | Up to 6 mm² |
| Tightening Torque | 2.1 N·m (screw clamp terminals) |
| Fire Resistance | 960 °C (IEC 60595-2-1) |
| Mechanical Durability | 100,000 cycles |
| Electrical Durability | 100,000 cycles (AC-21); 30,000 cycles (DC-1…5) |
| Mechanical Robustness (Vibration) | 10…150 Hz, 1 gn (IEC 60068-2-6) |
| Mechanical Robustness (Shock) | 11 ms, 30 Gn (IEC 60068-2-27) |
| Handle Front Plate Dimensions | 60 × 60 mm |
| Overall Dimensions (H × W × D) | 146 × 90 × 131 mm |
| Net Weight | 0.5 kg |
It provides a locally operated ON/OFF isolating function for a circuit, allowing equipment to be disconnected from the supply for maintenance or operational switching. This unit is suitable for isolation and uses a rotary handle for operation.
It is a 3-pole (3P) device, typically used for isolating three-phase circuits.
The rated operational voltage (Ue) is up to 690 V AC.
The conventional enclosed thermal current (Ithe) is 25 A.
The rated operational current (Ie) is 21.8 A at 400 V for AC-23A duty.
At 400 V, the rated operational power is 11 kW for AC-23 duty and 7.5 kW for AC-3 duty (typical motor switching applications).
The enclosure is rated IP65, offering dust-tight protection and resistance to water jets when correctly installed and used.
Yes. The rotary handle can be padlocked with 1 to 3 padlocks, with shackle diameter 4 to 8 mm, to help prevent unauthorised operation.
The rated conditional short-circuit current is 10 kA at 400 V when used with an associated 35 A aM or 35 A gG fuse. The rated short-circuit making capacity (Icm) is 1 kA at 400 V (Ipeak), and the rated short-time withstand current (Icw) is 384 A at 400 V for 1 second.
It uses screw clamp terminals and supports up to 10 mm² solid conductors and up to 6 mm² flexible conductors when fitted with cable ends.
The recommended tightening torque on the screw clamp terminals is 2.1 N·m.
Ambient air temperature for operation is -20 to 50 °C.
Overall dimensions are approximately 146 mm (H) x 90 mm (W) x 131 mm (D), with a net weight of about 0.5 kg for the unit (VBF1GE).
It is designed to conform to IEC 60204 and IEC 60947-4-1, as specified in the product documentation.
The handle marking is "0 - 1", indicating OFF (0) and ON (1) positions.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.