VBF1GE

Schneider VBF1GE available at EU Automation. Get in touch today for a quick price.

Trustpilot stars Based on over 4900 reviews

Full 12-month warranty

Available for dispatch immediately

We deliver worldwide

Get a quick price for VBF1GE

Quantity

Adding another part to your enquiry?

For more information on how your data is processed and stored by EU Automation please read our privacy policy.

All orders are subject to product availability. See our T&Cs.

Ask our team

What happens next?

1. Email confirmation

You will get an email confirming that we have received your enquiry.

2. Dedicated Account Manager

One of our team will be in touch to confirm your part(s) specification and condition.

3. Your quote

You will receive a comprehensive quote tailored to your specific needs.

Schneider Electric VBF1GE is a TeSys Vario enclosed switch disconnector designed for dependable on/off isolation in three-phase installations. This high-performance 3‑pole unit combines a robust IP65 enclosure with a black rotary handle and 0–1 marking for clear operating status. The handle is padlockable (1 to 3 padlocks, 4–8 mm) to help control access during preventive maintenance routines.

Rated for up to 690 V AC, the VBF1GE offers a conventional enclosed thermal current of 25 A and a rated operational current of 21.8 A in AC‑23A applications at 400 V. It supports motor and load switching duties with rated operational power up to 11 kW at 400 V (AC‑23) and 7.5 kW at 400 V (AC‑3). Screw clamp terminals accommodate up to 10 mm² solid or 6 mm² flexible conductors (with cable end), with a tightening torque of 2.1 N·m. The compact enclosure measures 146 mm (H) x 90 mm (W) x 131 mm (D) and is suited to standard industrial environments.
Specification Description
Manufacturer Schneider Electric
Part Number VBF1GE
Product Range TeSys
Series / Product Name TeSys VARIO
Product Type Enclosed switch disconnector (main switch disconnector)
Description Schneider Electric TeSys VARIO VBF1GE is an IP65 enclosed 3‑pole switch disconnector with a black rotary handle, designed for dependable ON/OFF isolation of three‑phase circuits in industrial control panels and machinery.
Poles 3P
Handle / Control Type Rotary handle
Handle Colour Black
Handle Front Plate Colour Black
Switch Positions / Marking 0 – 1
Padlocking Provision 1 to 3 padlocks (shackle diameter 4–8 mm)
Rated Operational Voltage (Ue) 690 V AC
Rated Impulse Withstand Voltage (Uimp) 8 kV
Conventional Enclosed Thermal Current (Ithe) 25 A
Rated Operational Current (Ie) 21.8 A (AC-23A at 400 V)
Rated Operational Power 11 kW at 400 V (AC-23); 7.5 kW at 400 V (AC-3)
Intermittent Duty Class 30
Making Capacity (I rms) 320 A at 400 V (AC-21A / AC-22A / AC-23A)
Short-Circuit Making Capacity (Icm) 1 kA at 400 V (Ipeak)
Short-Time Withstand Current (Icw) 384 A at 400 V for 1 s
Conditional Short-Circuit Current 10 kA at 400 V with associated fuse 35 A (aM or gG)
Breaking Capacity 250 A at 400 V (AC-21A / AC-22A / AC-23A)
Suitability for Isolation Yes
Degree of Protection IP65 (IEC 60529)
Standards IEC 60204; IEC 60947-4-1
Ambient Operating Temperature -20…50 °C
Connections / Terminals Screw clamp terminals
Conductor Capacity (Solid) Up to 10 mm²
Conductor Capacity (Flexible, with cable end) Up to 6 mm²
Tightening Torque 2.1 N·m (screw clamp terminals)
Fire Resistance 960 °C (IEC 60595-2-1)
Mechanical Durability 100,000 cycles
Electrical Durability 100,000 cycles (AC-21); 30,000 cycles (DC-1…5)
Mechanical Robustness (Vibration) 10…150 Hz, 1 gn (IEC 60068-2-6)
Mechanical Robustness (Shock) 11 ms, 30 Gn (IEC 60068-2-27)
Handle Front Plate Dimensions 60 × 60 mm
Overall Dimensions (H × W × D) 146 × 90 × 131 mm
Net Weight 0.5 kg

What does an enclosed switch disconnector do in an electrical installation?

It provides a locally operated ON/OFF isolating function for a circuit, allowing equipment to be disconnected from the supply for maintenance or operational switching. This unit is suitable for isolation and uses a rotary handle for operation.

How many poles does this switch disconnector have?

It is a 3-pole (3P) device, typically used for isolating three-phase circuits.

What is the rated operational voltage?

The rated operational voltage (Ue) is up to 690 V AC.

What is the thermal current rating for the enclosed assembly?

The conventional enclosed thermal current (Ithe) is 25 A.

What is the rated operational current at 400 V for switching duty?

The rated operational current (Ie) is 21.8 A at 400 V for AC-23A duty.

What motor and load power ratings can be expected at 400 V?

At 400 V, the rated operational power is 11 kW for AC-23 duty and 7.5 kW for AC-3 duty (typical motor switching applications).

What level of ingress protection does the enclosure provide?

The enclosure is rated IP65, offering dust-tight protection and resistance to water jets when correctly installed and used.

Can the rotary handle be padlocked in a specific position?

Yes. The rotary handle can be padlocked with 1 to 3 padlocks, with shackle diameter 4 to 8 mm, to help prevent unauthorised operation.

What short-circuit ratings are provided for coordination with upstream protection?

The rated conditional short-circuit current is 10 kA at 400 V when used with an associated 35 A aM or 35 A gG fuse. The rated short-circuit making capacity (Icm) is 1 kA at 400 V (Ipeak), and the rated short-time withstand current (Icw) is 384 A at 400 V for 1 second.

What cable sizes and terminal type does it use?

It uses screw clamp terminals and supports up to 10 mm² solid conductors and up to 6 mm² flexible conductors when fitted with cable ends.

What tightening torque should be used on the terminals?

The recommended tightening torque on the screw clamp terminals is 2.1 N·m.

What are the typical operating temperature limits?

Ambient air temperature for operation is -20 to 50 °C.

What are the overall dimensions and approximate weight?

Overall dimensions are approximately 146 mm (H) x 90 mm (W) x 131 mm (D), with a net weight of about 0.5 kg for the unit (VBF1GE).

Which standards does it conform to?

It is designed to conform to IEC 60204 and IEC 60947-4-1, as specified in the product documentation.

How is the switch position indicated on the device?

The handle marking is "0 - 1", indicating OFF (0) and ON (1) positions.

  • Main incoming isolator for three-phase control panels and small distribution boards
  • Local ON/OFF disconnect for machine sections to enable routine preventive maintenance
  • Lockable rotary handle isolation point for maintenance lockout procedures on equipment
  • Power disconnection for three-phase motor feeders (e.g., pumps, fans, conveyors and mixers)
  • Service switch for packaged machinery such as palletisers, wrappers and other packaging lines
  • Field-mounted disconnect in washdown or dusty areas where an IP65 enclosure is required
  • Isolation switch for HVAC plant items, including air handling units and rooftop equipment
  • Auxiliary isolation point for maintenance access on process skids and modular production units
  • Door-mounted operator switch for isolating a panel while keeping the switching device enclosed
  • Line isolator for small machine tools and workshop equipment using three-phase supplies

This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.

Delivery

  • Logistic partners UPS, FedEx and DHL
  • International delivery available
  • Premium nine hour delivery service available to anywhere in Europe
  • Same day dispatch from group stock

Warranty

All parts new or reconditioned are covered by EU Automation 12 month warranty

Returns

No hassle returns policy

Dedicated customer support team

Trade Credit

We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.

Payment options

We accept Bank transfers and the following methods of payment:

All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.

Services

Sourcing your part

Global supplier of quality automation and control components

Service Exchange

Dispose of your old unit by exchanging it for a working part.

Repair

A comprehensive repair service for faulty equipment.

Customer reviews

5 out of 5 stars steve

Got hold of Sime for a Carrier card for…


Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime

3 months ago

5 out of 5 stars Daniel

Excellent customer service...


Alex Bailey is my main point of contact at EU Automation...he is extremely friendly, has exceptional customer service skills and always offers great pricing & lead times.

5 months ago

5 out of 5 stars Jerry Schrink

Tom Higgins provided amazing service


Tom Higgins provided great prompt service. I contacted Tom by phone and within 10 minutes there was a quote in my in box. WOW Thank you Tom and Thank you EU Automation!

5 months ago

5 out of 5 stars Paulo Pereira

Excellent service and communication…


Excellent service and communication from Alex Bailey. He truly goes above and beyond to ensure his clients are 100% satisfied. The entire process was seamless, and his attention to detail made a huge difference. Highly recommended for anyone looking for amazing service!

5 months ago

5 out of 5 stars Gary

Tom Higgins did a great job at getting…


Tom Higgins did a great job at getting us the part we needed. He saw a concern with the part a verified before shipping.

6 months ago

5 out of 5 stars Lessle Smith

Thomas Higgins has gone above and…


Thomas Higgins has gone above and beyond to make things happen for my facility. His customer service and knowledge were an asset in helping me with my order and the logistics challenges!

6 months ago

Factory worker carrying automation parts box.

Our world, made possible by manufacturing. Manufacturing made possible by EU Automation.

Discover how we do our part to keep your production lines moving.

FAQs

View all FAQs

We're here when you need us