steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | 60161 |
| Product Range | Multi 9 |
| Product Type | C60N miniature circuit breaker |
| Circuit Breaker Type | Standard |
| Application | Short-circuit and overcurrent protection for loads with high inrush currents, including motors and transformers |
| Number of Poles | 2 |
| Rated Current | 10 A |
| Rated Voltage | 240 V AC |
| Frequency | 50/60 Hz |
| Trip Characteristic | D curve |
| Magnetic Trip Level | 10 to 14 times the rated current |
| Short-Circuit Current Rating | 10 kA at 240 V AC |
| Service Breaking Capacity | 75% of ultimate breaking capacity |
| High-Voltage Withstand | 6 kV |
| Terminal Configuration | Box lug at line and load |
| Conductor Compatibility | Copper conductors |
| Cable Capacity | 14–4 AWG (2–25 mm²) |
| Terminal Torque | 2.48 N·m (22 lb-in) |
| Mounting | 35 mm DIN rail; suitable for flush or surface installation |
| Enclosure Protection | IP40 |
| Terminal Protection | IP20 |
| Operating Temperature | -30 to +70 °C |
| Storage Temperature | -40 to +80 °C |
| Calibration Temperature | 25 °C |
| Dimensions | 107 mm high × 36 mm wide × 76 mm deep |
| Weight | Approximately 271 g |
| Electrical Endurance | 6,000 loaded operating cycles |
| Mechanical Endurance | 4,000 no-load operating cycles |
| Feed Direction | Suitable for reverse feeding |
| Compliance | UL 489 listed, CSA C22.2 No. 5.1 certified, IEC 60947-2 and CE marked |
| Additional Rating | HACR rated |
This is a Schneider Multi 9 C60N miniature circuit breaker designed to protect electrical circuits against overcurrent and short circuits.
The circuit breaker has a rated current of 10 A when calibrated at 25°C.
Schneider 60161 is rated for operation at up to 240 V AC.
It is a two-pole circuit breaker, allowing two conductors to be disconnected together.
The unit uses a D-curve tripping characteristic. Its magnetic release operates at approximately 10 to 14 times the rated current.
A D-curve breaker is suited to loads that can produce high starting currents, including motors, transformers and similar inductive equipment.
The breaker has a short-circuit current rating of 10 kA at 240 V AC.
It can be installed on a standard 35 mm DIN rail and is also suitable for flush or surface mounting within compatible panels and enclosures.
The device has box-lug terminals on both the line and load sides, intended for use with copper conductors.
The listed conductor range for Schneider 60161 is 18 to 4 AWG. Installation requirements and terminal torque values should be checked before fitting.
The circuit breaker measures approximately 36 mm wide, 107 mm high and 76 mm deep.
The breaker case is rated IP40, while the terminals are rated IP20.
The unit is listed to UL 489, certified to CSA C22.2 No. 5.1 and rated in accordance with IEC 60947-2. It is also CE marked.
Yes. The Multi 9 C60 design permits reverse feeding, provided the installation complies with the applicable electrical requirements.
Yes. The Multi 9 system supports compatible plug-on accessories such as auxiliary contacts, alarm switches, shunt-trip modules and undervoltage releases.
The specified operating temperature range is -30°C to 70°C, with calibration based on an ambient temperature of 25°C. Rating adjustments may be necessary at higher temperatures.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.