steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
2 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Pilz |
| Part number | PSEN CS4.1P |
| Manufacturer order number | 541 160 |
| Product type | Coded guard door switch (non-contact) |
| Sensing principle | Transponder technology |
| Coding type (Pilz) | Fully coded |
| Coding level (EN ISO 14119) | High |
| Device type (EN ISO 14119) | Type 4 |
| Classification (EN 60947-5-3) | PDDB |
| Typical application | Position monitoring of movable guards and doors on industrial machinery |
| Compatible actuators | PSEN cs4.1 actuator (541 180); PSEN cs2.1 actuator (540 180) |
| Operating frequency band | 122 kHz – 128 kHz |
| Max. transmitter output | 15 mW |
| Supply voltage | 24 V DC |
| Supply voltage tolerance | -20% / +20% |
| External power supply requirement | 1 W (DC) |
| Current consumption (no-load) | 20 mA |
| Inrush current impulse | 0.58 A (1 ms) |
| Number of inputs | 2 |
| Input voltage | 24 V DC |
| Input current | 5 mA |
| Safety outputs | 2 semiconductor outputs (OSSD) |
| Switching current per output | 100 mA |
| Switching power per output | 2.4 W |
| Residual current at outputs | 20 µA |
| Voltage drop at OSSDs | 3.5 V |
| Max. switching frequency | 3 Hz |
| Max. test pulse duration (safety outputs) | 450 µs |
| Switch-on delay after UB applied | 1 s |
| Response time (inputs) | Typical 13 ms; max. 20 ms |
| Response time (actuator) | Typical 60 ms; max. 150 ms |
| Drop-out delay (inputs) | Typical 15 ms; max. 20 ms |
| Drop-out delay (actuator) | Typical 40 ms; max. 260 ms |
| Risk time (EN 60947-5-3) | 260 ms |
| Supply dip bridging | 10 ms |
| Operating distances with PSEN cs4.1 actuator | Assured ON Sao: 8 mm; typical ON So: 11 mm; typical OFF Sr: 14 mm; assured OFF Sar: 20 mm |
| Operating distances with PSEN cs2.1 actuator | Assured ON Sao: 10 mm; typical ON So: 25 mm; typical OFF Sr: 29 mm; assured OFF Sar: 33 mm |
| Typical hysteresis | 2 mm (with PSEN cs4.1 actuator); 3 mm (with PSEN cs2.1 actuator) |
| Repeat accuracy of switching distances | 10% |
| Switching distance change vs temperature | ±0.01 mm/°C (with PSEN cs4.1 actuator); ±0.1 mm/°C (with PSEN cs2.1 actuator) |
| Minimum distance between switches | 100 mm |
| Connection type | 8-pin M8 male connector |
| Housing material (top) | PBT |
| Tightening torque (mounting screws) | 0.8 Nm |
| Dimensions (H × W × D) | 37 mm × 26 mm × 18 mm |
| Weight | 35 g |
| Degree of protection (housing) | IP6K9K |
| Degree of protection (connector) | IP67 |
| Ambient temperature range | -25 °C to +70 °C |
| Storage temperature range | -25 °C to +70 °C |
| Humidity | 93% RH at 40 °C |
| Vibration | 10–55 Hz, 1 mm amplitude (EN 60947-5-2) |
| Shock | 30 g, 18 ms (EN 60947-5-2) |
| Overvoltage category | III |
| Pollution degree | 3 |
| Rated insulation voltage | 60 V |
| Rated impulse withstand voltage | 0.8 kV |
| Approvals / markings | CE, EAC (Eurasian), FCC, IC, TÜV, cULus Listed |
It is a non-contact, coded transponder switch used to monitor the position of a movable guard (such as a door or cover). When the taught-in actuator is within the response range, the device enables its two safe semiconductor outputs for connection to a suitable evaluation unit.
Yes. The switch is supplied as a sensor only and needs a compatible coded actuator. Common matched actuators in this family include the PSEN cs4.1 actuator (e.g., order no. 541180) and other approved variants depending on the mechanical design.
This model uses a fully coded transponder principle, so it responds only to a taught-in actuator. This helps prevent actuation by nearby, non-matching actuators and supports more controlled access monitoring.
A total of up to 8 learning (teach-in) procedures are possible. Each successful teach-in reduces the remaining count by one, so it is best to plan actuator management during commissioning and maintenance.
With parallel, face-to-face installation using the matched cs4.1 actuator, the typical operating distance is about 11 mm and the assured operating distance (Sao) is 8 mm. The assured release distance (Sar) is 20 mm. Distances can vary if installed in other orientations or near conductive materials.
It is designed for 24 V DC operation (with a tolerance of -20% to +20%). Power consumption is approximately 1 W for the device.
It provides two OSSD-style safe semiconductor outputs and two input channels. This supports two-channel monitoring with plausibility checking when used with an appropriate evaluation device.
This variant uses an 8-pin M8 male connector. Typical pin functions include: supply (+24 V and 0 V), two output channels (12/22), two input channels (S11/S21), and diagnostic signalling (Y1/Y32) for additional status/diagnostics integration.
Yes, it can be wired in series. When designing a series connection, the overall system design should consider diagnostic needs, voltage drop, and measures to reduce bypassing, as well as the requirements of the chosen evaluation device.
The device includes LEDs for Power/Fault and gate status. Typical indications include: green Power/Fault for ready state, yellow Safety Gate when the actuator is in range, and red Power/Fault for an error condition. The Input LED can also indicate input state and certain fault patterns (such as partial operation).
Yes. The device supports an optional diagnostics concept (often referred to as Safety Device Diagnostics) that can be used with a suitable fieldbus module to read device information and status across a series connection.
The housing is rated to IP6K9K, and the connector area is typically IP67 when properly mated. This suits harsh industrial environments where washdown or high ingress protection is required.
Install the switch and actuator opposite each other and parallel for the stated distances, align the marked faces so the arrows face each other, and keep at least 100 mm spacing between adjacent switches. Use appropriate mounting hardware (typically M4 with flat underside head) and observe the recommended maximum tightening torque of 0.8 Nm for fixing screws.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.