2906809

Phoenix Contact 2906809 available at EU Automation. Get in touch today for a quick price.

Trustpilot stars Based on over 4900 reviews

Full 12-month warranty

Available for dispatch immediately

We deliver worldwide

Get a quick price for 2906809

Quantity

Adding another part to your enquiry?

For more information on how your data is processed and stored by EU Automation please read our privacy policy.

All orders are subject to product availability. See our T&Cs.

Ask our team

What happens next?

1. Email confirmation

You will get an email confirming that we have received your enquiry.

2. Dedicated Account Manager

One of our team will be in touch to confirm your part(s) specification and condition.

3. Your quote

You will receive a comprehensive quote tailored to your specific needs.

Phoenix Contact 2906809 is a slim DIN-rail surge protection device (TTC-6P-1X2-24DC-UT-I) designed to protect 24 V DC, 2-wire floating signal circuits such as 0(4)–20 mA current loops, including HART-compatible instrumentation. The unit consists of a base element and a pluggable protective module, enabling quick replacement without disturbing the signal and ensuring correct module selection through coding. An integrated mechanical status indicator provides clear local condition monitoring without the need for auxiliary power.

Built for space-efficient cabinet layouts, it fits a 6.2 mm wide installation footprint and mounts on standard TH 35 rails. It supports screw connections and is suitable for harsh industrial environments with an operating temperature range of -40 °C to +85 °C. With defined surge performance to IEC 61643-21, it helps reduce downtime and protect sensitive measurement and control wiring from transient overvoltages.

What does this surge protection device protect in an industrial control system?

It is designed to protect sensitive 2‑wire signal circuits from transient overvoltages, diverting surge energy away from connected instrumentation and control inputs while keeping the circuit operating conditions stable.

Which signal types is it typically used with?

It is intended for 2‑wire floating signal circuits such as 0(4)–20 mA current loops and is suitable for use with HART-compatible loops.

What is the nominal operating voltage for the protected circuit?

The nominal voltage is 24 V DC, with a maximum continuous voltage of 30 V DC (also specified as 21 V AC).

Will it affect my analogue signal during normal operation?

It is designed for low impact on the signal path, with low leakage current (≤ 5 µA at maximum continuous voltage) and specified insertion attenuation of typically 0.3 dB (≤ 250 kHz in a 150 Ω system).

Is the module suitable for maintenance without disturbing the loop?

Yes. The protective element is pluggable, and insertion/removal is intended to be impedance-neutral so the signal is not influenced during maintenance work.

How can I tell if the protection is still functioning?

It includes an integrated, mechanical status indicator on the module, providing visual condition monitoring without requiring an auxiliary power supply.

Can it be monitored remotely as part of a larger panel build?

Yes. An optional remote signalling module set can be used to monitor neighbouring devices in the same product range; the TTC-6-FMRS-UT accessory is specified to monitor up to 40 items.

What are the surge performance ratings?

Key ratings include nominal discharge current In (8/20 µs) of 5 kA line-line and 5 kA line-earth, pulse discharge current Iimp (10/350 µs) of 0.5 kA line-line and 0.5 kA line-earth, and a total discharge current Itotal (8/20 µs) of 10 kA.

What are the voltage protection levels (clamping levels)?

For line-line protection, the voltage protection level Up is specified as ≤ 200 V (C1), ≤ 320 V (C2), and ≤ 50–55 V (C3, depending on test current). For line-earth, Up is specified around ≤ 700–750 V across the listed test classes.

How fast does it respond to a surge event?

Response time is specified as ≤ 1 ns for line-line and ≤ 100 ns for line-earth.

What mounting method and panel footprint should I plan for?

It is a DIN-rail module for TH 35 rails. The housing is narrow at 6.2 mm wide (plus tolerance), with dimensions of approximately 105.8 mm high and 100 mm deep (including DIN rail 7.5 mm).

What wiring connections does it use?

It uses screw connections with an M3 thread. The recommended tightening torque is 0.5–0.6 Nm, stripping length is 8 mm, and supported conductor sizes are 0.2–2.5 mm² (flexible) and 0.2–4 mm² (solid), approximately AWG 24–12.

Is there a recommended back-up fuse for the signal loop?

Yes. The maximum required back-up fuse is specified as 630 mA (FF).

What environmental conditions can it operate in?

The operating temperature range is -40 °C to +85 °C. Permissible operating humidity is 5% to 95%, and it is specified for use up to 4000 m altitude (above mean sea level).

What ingress protection rating does the housing provide?

The device is rated IP20, suitable for installation inside an appropriate enclosure.

Does it have recognised approvals for industrial applications?

It is listed with approvals including UL Listed, CSA, and DNV GL (approval identifiers are provided in the manufacturer’s documentation).

Are replacement or add-on components available for this unit?

Yes. The surge protection plug can be replaced (for example, TTC-6P-1X2-24DC-I-P is listed as a spare part). Accessories include a fuse carrier (TTC-6-FC-UT) and remote signalling module set (TTC-6-FMRS-UT).

Can the module be tested for documentation purposes?

Yes. It is designed to support straightforward testing and documentation using CHECKMASTER 2 with pluggable protective modules.

What is included in the product assembly?

It consists of a base element and a protective plug, forming a divisible, two-section DIN-rail surge protection assembly (often referenced as TTC-6P-1X2-24DC-UT-I; Phoenix Contact 2906809).

  • Protecting 24 V DC, 2‑wire analogue signal loops such as 0(4)–20 mA instrumentation circuits from surge and transient overvoltage events
  • Improving resilience of HART-compatible field signals in process measurement and control panels
  • DIN-rail surge protection for PLC and DCS analogue input/output marshalling where compact width is important
  • Reducing disturbance-related downtime on long cable runs between field transmitters and control-room equipment
  • Protecting monitoring circuits for pressure, temperature, flow, and level transmitters operating on floating signal circuits
  • Enhancing EMC robustness for signals routed through junction boxes, marshalling cabinets, and instrumentation racks
  • Adding pluggable surge protection to allow quick module replacement while maintaining continuity of the signal wiring
  • Providing local status indication of the protective element to support routine inspection in control cabinets
  • Protecting signals in industrial utilities such as water and wastewater treatment, energy-from-waste, and general plant services
  • Mitigating lightning-induced and switching transient effects on outdoor-connected sensors feeding indoor control systems

This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.

Delivery

  • Logistic partners UPS, FedEx and DHL
  • International delivery available
  • Premium nine hour delivery service available to anywhere in Europe
  • Same day dispatch from group stock

Warranty

All parts new or reconditioned are covered by EU Automation 12 month warranty

Returns

No hassle returns policy

Dedicated customer support team

Trade Credit

We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.

Payment options

We accept Bank transfers and the following methods of payment:

All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.

Services

Sourcing your part

Global supplier of quality automation and control components

Service Exchange

Dispose of your old unit by exchanging it for a working part.

Repair

A comprehensive repair service for faulty equipment.

Customer reviews

5 out of 5 stars steve

Got hold of Sime for a Carrier card for…


Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime

4 weeks ago

5 out of 5 stars Daniel

Excellent customer service...


Alex Bailey is my main point of contact at EU Automation...he is extremely friendly, has exceptional customer service skills and always offers great pricing & lead times.

2 months ago

5 out of 5 stars Jerry Schrink

Tom Higgins provided amazing service


Tom Higgins provided great prompt service. I contacted Tom by phone and within 10 minutes there was a quote in my in box. WOW Thank you Tom and Thank you EU Automation!

2 months ago

5 out of 5 stars Paulo Pereira

Excellent service and communication…


Excellent service and communication from Alex Bailey. He truly goes above and beyond to ensure his clients are 100% satisfied. The entire process was seamless, and his attention to detail made a huge difference. Highly recommended for anyone looking for amazing service!

2 months ago

5 out of 5 stars Gary

Tom Higgins did a great job at getting…


Tom Higgins did a great job at getting us the part we needed. He saw a concern with the part a verified before shipping.

3 months ago

5 out of 5 stars Lessle Smith

Thomas Higgins has gone above and…


Thomas Higgins has gone above and beyond to make things happen for my facility. His customer service and knowledge were an asset in helping me with my order and the logistics challenges!

4 months ago

Factory worker carrying automation parts box.

Our world, made possible by manufacturing. Manufacturing made possible by EU Automation.

Discover how we do our part to keep your production lines moving.

FAQs

View all FAQs

We're here when you need us