steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LC4H-R6-DC24VS |
| Alternative Part Number | LC4HR6DC24VS |
| Manufacturer | Panasonic |
| Display Type | 6-digit, 7-segment LCD with 2-colour backlight (red for counter value, yellow for set value) |
| Count Speed | 30 Hz (cps) / 5 KHz (kcps) switchable |
| Operation Modes | Addition (UP), Subtraction (DOWN), Direction (DIR), Independent (IND), Phase (PHASE) |
| Output Types | Relay (1c) and Transistor (1a) |
| Operating Voltage | 12-24 V DC |
| Terminal Types | Screw terminal and 11-pin types available |
| Protective Construction | Conforms to IP66 for water and dust resistance |
| Memory Retention | Power failure memory retention with EE-PROM (overwriting times: 10^5 ops. or more) |
| Control Output Rating | Relay: 5 A, 250 V AC (resistive); Transistor: 100 mA, 30 V DC |
| Operating Temperature | -10°C to 55°C (+14°F to +131°F) |
| Humidity Resistance | Up to 85% RH without condensation |
| Vibration Resistance | 10 to 55 Hz with single amplitude of 0.35 mm (.014 inch) for 10 min on 3 axes |
| Shock Resistance | Functional: 98 m/s^2 (10 times on 3 axes); Destructive: 294 m/s^2 (5 times on 3 axes) |
| Installation | Suitable for both surface and flush mounting with accessories for DIN rail or panel installation |
| Compliance | EMC directives (EN50081-2/EN50082-2) and low-voltage directives (VDE0435/Part 2021) |
The operation mode can be set using the DIP switches located on the side of the unit. Refer to the datasheet for specific DIP switch configurations to select the desired input and output modes.
The counter accepts contact point inputs and non-contact point inputs such as open collector transistors. Ensure that the characteristics of the transistors used satisfy the specified criteria in the datasheet.
The counter is designed to conform to IP66 weather-resistant standards, which means it can withstand water and dirt ingress. However, it should be installed in a location that minimises exposure to harsh environmental conditions.
The maximum counting speed of the counter is switchable between 30 Hz (cps) and 5 kHz (Kcps), selectable by a DIP switch.
The set value can be changed using the seesaw buttons located on the front of the unit. You can increase or decrease the value of the corresponding digit of the set value display even during counting.
First, ensure that the input signals meet the specifications detailed in the datasheet. Check the wiring and DIP switch settings for accuracy. If the issue persists, consult the self-diagnosis function of the counter for further troubleshooting.
Yes, the counter features power failure memory retention. The set value and displayed counts are retained in memory, so no data is lost during a power failure.
The counter can be surface-mounted using the pin type timer or flush-mounted using the built-in screw terminal type. Mounting frames and rubber gaskets are provided with the timer for secure installation.
To protect the counter from power supply surges, use a surge absorbing element as specified in the datasheet. This will prevent potential damage to the internal circuits.
When connecting an inductive load, use a diode to absorb the reverse voltage from the load. Ensure the diode's rating is suitable for the load's characteristics.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.