steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Moeller |
| Part Number | 063960 |
| Manufacturer Reference / Type | B3.0/4-PKZ0 |
| Product Type | Three-phase commoning link (accessory) |
| Summary Description | Insulated three-phase commoning link designed to provide a parallel power feed to multiple motor-protective circuit-breakers via terminals 1, 3, and 5, offering a compact and orderly panel connection solution. |
| Compatible Device Series | PKZM0 series motor-protective circuit-breakers; PKE series (when fitted without side-mounted auxiliary contacts or shunt releases) |
| Number of Phases | 3 |
| Number of Devices Fed | 4 motor-protective circuit-breakers |
| Rated Operational Voltage (Ue) | 690 VAC |
| Rated Uninterrupted Current (Iu) | 63 A |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Overvoltage Category / Pollution Degree | III / 3 |
| Contact Protection | Protected against accidental contact; short-circuit proof design |
| Electrical Connection Design | Fork connector |
| Insulation | Yes (insulated) |
| Length | 180 mm |
| Unit Width | 45 mm |
| Standards / Approvals | IEC 60947-4-1; UL 508; CSA C22.2 No. 14; CE marking |
| Suitable for Devices with Auxiliary Contacts | No |
| Suitable for Devices with Neutral Pole | No |
It is used to create a shared three-phase line-side feed so multiple motor-protective circuit-breakers can be supplied in parallel from one incoming three-phase supply, reducing individual jumper wiring.
It is designed for Moeller/Eaton PKZM0 series motor-protective circuit-breakers and PKE devices, provided they are used without side-mounted auxiliary contacts or shunt releases.
No. This style is intended for assemblies without side-mounted auxiliary contacts or shunt releases, as those accessories can interfere with the side profile and fitment.
It is intended for parallel power feed on the line-side terminals 1, 3, and 5 of compatible motor-protective circuit-breakers.
Key ratings include a maximum rated operational voltage of up to 690 V AC and a rated uninterrupted current of 63 A (values commonly referenced for Moeller 063960). Always verify suitability against the full assembly design and protective coordination.
It uses a fork-connector style interface intended to mate with the compatible device terminal arrangement for quick commoning across phases.
Yes. It is an insulated, touch-protected design intended to be short-circuit proof as an accessory within the compatible starter/circuit-breaker assembly.
It is designed to common a group of devices in a row; the practical number depends on the specific starter layout and the link variant/spacing used. This particular version is commonly used for multi-device feeding in compact motor starter assemblies.
It is described as extendable by rotating during installation, allowing flexibility in how the commoning link is positioned within the assembly (subject to the mechanical arrangement of the devices).
The unit width is 45 mm, and the overall length is approximately 180 mm, which helps when planning rail layout and clearances in a control panel.
No. It is a three-phase commoning link and is not intended for neutral-pole distribution.
It is typically referenced with industrial control and low-voltage switchgear standards such as IEC 60947-4-1, and it is commonly associated with UL 508 and CSA C22.2 No. 14 approvals when used within appropriate assemblies.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.