Siemens 5SU1656-7KK32 is a SENTRON residual current operated circuit breaker with overcurrent protection (RCBO) designed for compact, reliable protection in single-phase distribution boards. It combines overload and short-circuit protection with residual current protection in a 1P+N (two-pole) format, using a Type A residual current characteristic and a C tripping curve to suit circuits with moderate inrush currents.

Rated at 32 A and 230/240 V AC, the device provides a 6 kA short-circuit breaking capacity to EN 61009-1, with energy limitation class 3 to help reduce stress on downstream cabling and equipment during fault conditions. It is built for long service with a typical mechanical endurance of 10,000 operating cycles and is suitable for overvoltage category III, pollution degree 2 environments.

The 5SU1656-7KK32 is a two-module device (36 mm wide) with dimensions of 90 mm (H) x 36 mm (W) x 77 mm (D) and an installation depth of 70 mm, allowing efficient panel layout. It supports solid and stranded conductors from 0.75 to 35 mm² (finely stranded with end processing up to 25 mm²) with screw terminals tightened to 2.5–3 N·m, and can be supplied from either the top or bottom. Halogen-free and silicon-free construction and an operating temperature range of -25 °C to +55 °C make it well suited to a wide range of commercial and industrial installations.

What does this device do in an electrical distribution board?

It is an RCBO (Residual Current Breaker with Overcurrent protection) that combines two functions in one module: protection against overload/short-circuit (like an MCB) and protection against earth leakage (like an RCD). It is a 1P+N design, switching both live and neutral.

What are the rated current and operating voltage?

Rated current is 32 A at 30 °C ambient. The rated operating voltage is 230/240 V AC at 50 Hz (AC supply).

What tripping characteristic does it have, and when is it typically used?

It has a C-type tripping characteristic, commonly selected for circuits with moderate inrush currents (for example, certain lighting loads and small motors), where avoiding nuisance trips is important compared with B-curve devices.

What residual current type and sensitivity does it provide?

It is Type A residual-current protection with a sensitivity of 300 mA. Type A is intended to detect alternating residual currents and pulsating DC residual currents.

What short-circuit breaking capacity does it offer?

Its rated short-circuit breaking capacity (Icn) is 6 kA according to EN 61009-1. It also states 6 kA according to EN 60898 and 15 kA according to IEC 60947-2.

How many poles are included, and how is the neutral treated?

It is a 2-pole device in a 1P+N configuration. One pole is protected and the neutral is switched, which helps isolate the circuit while maintaining the intended protection scheme.

What is the module width and overall size?

It occupies 2 modular width units (36 mm). Typical dimensions are 90 mm (height) × 36 mm (width) × 77 mm (depth), with an installation depth of about 70 mm.

What conductor sizes can be connected to the terminals?

Solid conductors: 0.75 to 35 mm². Stranded conductors: 0.75 to 35 mm². Finely stranded conductors with end processing (for example, ferrules): 0.75 to 25 mm².

What terminal tightening torque should be used?

For the screw-type terminals, the specified tightening torque range is 2.5 to 3.0 N·m.

Can the supply be connected from the top or the bottom?

Yes. The power supply connection can be made either from the top or from the bottom, depending on the distribution board layout.

How does ambient temperature affect the usable current rating?

The current rating is temperature dependent. Examples given include 32 A at 30 °C, 30.4 A at 40 °C, 29.76 A at 45 °C, 28.8 A at 50 °C, and 27.84 A at 55 °C. This is useful when sizing circuits in warmer enclosures.

What are the operating and storage temperature ranges?

Operating ambient temperature range is -25 °C to +55 °C. Storage ambient temperature range is -40 °C to +75 °C.

What ingress protection rating applies once installed?

It is rated IP20 when installed in a distribution board with connected conductors.

What is the typical internal power loss?

Maximum power loss is stated as 5.7 W, which can be helpful when considering enclosure temperature rise and spacing.

Are there any material features noted for panel-building requirements?

Yes. Product features include halogen-free and silicon-free construction. If you need to reference it internally, this corresponds to Siemens part 5SU1656-7KK32.

  • Combined overload, short-circuit and earth-leakage protection for single-phase final circuits in commercial distribution boards
  • Protection of socket-outlet circuits where both overcurrent protection and Type A residual-current detection are required
  • Securing lighting circuits and mixed-use radial circuits with a C-curve inrush tolerance (e.g., LED drivers and small motors)
  • Circuit protection for workshop and plant-room supplies such as pumps, fans and compressors on 230 V systems
  • Use in small commercial units and retail fit-outs to provide individual circuit fault protection and isolation within DIN-rail consumer units
  • Protection of dedicated supplies for office equipment circuits, including general power and small fixed appliances
  • Segregated protection for outbuildings, garages and ancillary areas fed from a main distribution board
  • Residual-current protection for circuits that may include pulsed DC components, suitable for modern electronic loads (Type A)
  • Integration into panel builds where a compact 1P+N RCBO is preferred to reduce the number of protective devices per circuit
  • Use as a branch protection device in modular electrical enclosures requiring 6 kA breaking capacity at 230/240 V AC

This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.

Delivery

  • Logistic partners UPS, FedEx and DHL
  • International delivery available
  • Premium nine hour delivery service available to anywhere in Europe
  • Same day dispatch from group stock

Warranty

All parts new or reconditioned are covered by EU Automation 12 month warranty

Returns

No hassle returns policy

Dedicated customer support team

Trade Credit

We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.

Payment options

We accept Bank transfers and the following methods of payment:

All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.

Services

Sourcing your part

Global supplier of quality automation and control components

Service Exchange

Dispose of your old unit by exchanging it for a working part.

Repair

A comprehensive repair service for faulty equipment.

Customer reviews

5 out of 5 stars steve

Got hold of Sime for a Carrier card for…


Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime

4 weeks ago

5 out of 5 stars Daniel

Excellent customer service...


Alex Bailey is my main point of contact at EU Automation...he is extremely friendly, has exceptional customer service skills and always offers great pricing & lead times.

2 months ago

5 out of 5 stars Jerry Schrink

Tom Higgins provided amazing service


Tom Higgins provided great prompt service. I contacted Tom by phone and within 10 minutes there was a quote in my in box. WOW Thank you Tom and Thank you EU Automation!

2 months ago

5 out of 5 stars Paulo Pereira

Excellent service and communication…


Excellent service and communication from Alex Bailey. He truly goes above and beyond to ensure his clients are 100% satisfied. The entire process was seamless, and his attention to detail made a huge difference. Highly recommended for anyone looking for amazing service!

2 months ago

5 out of 5 stars Gary

Tom Higgins did a great job at getting…


Tom Higgins did a great job at getting us the part we needed. He saw a concern with the part a verified before shipping.

3 months ago

5 out of 5 stars Lessle Smith

Thomas Higgins has gone above and…


Thomas Higgins has gone above and beyond to make things happen for my facility. His customer service and knowledge were an asset in helping me with my order and the logistics challenges!

4 months ago

Factory worker carrying automation parts box.

Be a Factory Hero.

Get parts fast.

You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.

Be a Factory Hero

FAQs

View all FAQs

We're here when you need us