steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Manufacturer Part Number (MPN) | 3VA6110-6HM31-0AA0 |
| Alternative Part Number | 3VA61106HM310AA0 |
| Product Range | SENTRON 3VA6 |
| Product Type | Molded-case circuit breaker (MCCB) |
| Product Description | Compact Siemens SENTRON 3VA6 three‑pole moulded-case circuit breaker with ETU330 electronic trip unit, designed for dependable system protection with adjustable overload, instantaneous short-circuit and earth-fault functions in low-voltage distribution applications. |
| Frame Size (UL) | Frame 150 |
| Number of Poles | 3 |
| Trip Unit | ETU330 (electronic) |
| Protection Functions | LIG (Overload + Instantaneous short-circuit + Ground-fault) |
| Rated Current (In / Iu) | 100 A |
| Frame Rated Current (maximum) | 150 A |
| Rated Operational Voltage (AC) | Up to 690 V AC, 50/60 Hz |
| Rated Insulation Voltage (Ui) | 800 V |
| Breaking Capacity Class | Class H (high breaking capacity) |
| UL 489 Interrupting Rating | 65 kA at 480 V; 100 kA at 240 V; 22 kA at 600 V |
| IEC 60947-2 Ultimate Breaking Capacity (Icu) | 110 kA at 240 V; 85 kA at 415 V; 2.5 kA at 690 V |
| IEC 60947-2 Service Breaking Capacity (Ics) | 110 kA at 240 V; 85 kA at 415 V; 2.5 kA at 690 V |
| Making Capacity (Icm) | 242 kA at 240 V; 187 kA at 415 V; 3.8 kA at 690 V |
| Overload Setting Range (Ir) | Adjustable 40 A to 100 A (I²t characteristic) |
| Overload Time Delay (tr) | Adjustable 0.5 s to 17 s |
| Instantaneous Short-Circuit Setting (Ii) | Adjustable 150 A to 1,200 A (1.5 to 12 × In) |
| Ground-Fault Pickup (Ig) | Adjustable 20 A to 100 A (0.2 to 1 × In) |
| Ground-Fault Time Delay (tg) | Adjustable 0.1 s to 0.3 s |
| Ground-Fault I²t (ON/OFF) | Switchable (I²t ON/OFF) |
| Ground-Fault Monitoring Method | Summation current formation (L-conductor) |
| 100%-Rated Breaker (UL 489) | No |
| HACR Type (UL 489) | Yes |
| Power Loss (maximum) | 13 W |
| Power Loss per Pole | 4.33 W |
| Mechanical Endurance | Typical 25,000 operating cycles |
| Electrical Endurance (AC-1) | 14,000 cycles at 380/415 V; 9,800 cycles at 690 V |
| Degree of Protection (front) | IP40 |
| Operating Ambient Temperature | -25 °C to +70 °C |
| Storage Temperature | -40 °C to +80 °C |
| Dimensions (H × W × D) | 198 mm × 105 mm × 86 mm |
| Net Weight | 2.5 kg |
| Main Circuit Connection | Without connection (terminals not supplied) |
| Auxiliary Contacts | 0 CO contacts fitted |
| Optional Accessory Capability | Motor drive: optional |
| Communication Function | No |
It is a SENTRON 3VA6 moulded-case circuit breaker designed for system/line protection in low-voltage distribution, such as switchboards, panelboards, and industrial control panels where adjustable electronic protection is required.
This unit is a 3-pole circuit breaker, intended for three-phase circuits.
The breaker has a rated continuous current (In/Iu) of 100 A, and the long-time (overload) pickup Ir is adjustable from 40 A to 100 A via the electronic trip unit.
It uses an ETU330 electronic trip unit with LIG protection: L (long-time overload), I (instantaneous short-circuit), and G (ground-fault) protection.
Key adjustable ranges include: long-time pickup Ir 40–100 A with long-time delay tr 0.5–17 s; instantaneous pickup Ii 150–1,200 A (approximately 1.5–12 × In); and ground-fault pickup Ig 20–100 A (0.2–1 × In) with ground-fault delay tg 0.1–0.3 s.
Ground-fault protection is provided with adjustable settings, but the device documentation indicates the ground-fault function is not switchable ON/OFF (i.e., it is not intended to be disabled).
Short-circuit capacity depends on the standard and system voltage. Under IEC 60947, typical values include Icu/Ics up to 110 kA at 240 V and 85 kA at 415 V (and 2.5 kA at 690 V). Under UL 489, typical interrupting ratings include 100 kA at 240 V, 65 kA at 480 V, and 22 kA at 600 V. Always match the rating to the installation voltage and standard being applied.
It is intended for low-voltage AC systems up to 690 V (50/60 Hz) depending on the applicable standard and installation requirements. The datasheet also lists a rated insulation voltage up to 800 V.
It is supplied without main-circuit connection accessories (listed as “without connection”), so suitable line/load terminals or connection kits must be selected separately to suit the conductor type and mounting arrangement.
Approximate overall dimensions are 198 mm (H) × 105 mm (W) × 86 mm (D). The protection class on the front is IP40.
A neutral conductor pole is not included, and the device is specified as not upgradeable/retrofittable for neutral conductors.
No. The unit is specified with 0 changeover (CO) contacts for auxiliary contacts as standard; auxiliary signalling requires separate accessories where applicable.
No. The listed product components indicate no undervoltage release and no voltage trigger (shunt trip) integrated as supplied.
Yes. The breaker supports an optional motor drive (motor operator) as an accessory, enabling remote opening/closing where the installation design requires it.
Typical ambient temperature ranges are -25 °C to +70 °C during operation, and -40 °C to +80 °C during storage.
Typical mechanical endurance is around 20,000 operating cycles. Maximum power loss is stated as about 13 W (approximately 4.33 W per pole at rated current). For referencing in documentation, this unit may be identified as Siemens 3VA6110-6HM31-0AA0.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.