steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | PU300 |
| Alternative Part Number | PU300 |
| Manufacturer | Selectron |
| Power Output | 200-300 watts continuous output power |
| Input Voltage | 90-264 VAC |
| Input Frequency | 47-63 Hz |
| Input Current | 4.7 A (rms) for 115 VAC, 2.3 A (rms) for 230 VAC |
| Earth Leakage Current | 300 μA max. @ 264 VAC, 63 Hz |
| Output Voltage/Current | Multiple models with various outputs, see rating chart |
| Ripple and Noise | 1% peak to peak maximum |
| Overvoltage Protection | Provided on output #1 only; set at 115-140% of its nominal output voltage |
| Overcurrent Protection | All outputs protected to short circuit conditions |
| Temperature Coefficient | All outputs ±0.04% / ℃ maximum |
| Transient Response | Maximum excursion of 4% or better on all models, recovering to 1% of final value within 500 us |
| Fan Power | 12 V at 350 mA maximum for B version, 12 V at 100 mA maximum for C version |
| Operating Temperature | 0 to +70℃ |
| Storage Temperature | -40 to +85℃ |
| Relative Humidity | 5% to 95% non-condensing |
| Derating | Derate from 100% at +50℃ linearly to 50% at +70℃ |
| Cooling | 35 CFM forced air cooling or convection cooling |
| Switching Frequency | 70 KHz ± 10 KHz |
| Power Factor | 0.98 typical |
| Efficiency | 70% minimum on all models |
| Hold-up Time | 12 ms minimum at 110 VAC |
| Line Regulation | ±0.2% maximum at full load |
| Inrush Current | 30 A @ 115 VAC or 60A @ 230 VAC, at 25℃ cold start |
| Withstand Voltage | 3000 VAC from input to output, 1500 VAC from input to ground, 500 VAC from output to ground |
| MTBF | 300,000 hours minimum at full load at 25℃ ambient, calculated per MIL-HDBK-217F |
| EMC Performance | Compliant with multiple EMC standards including EN55022 and EN61000 series |
| Safety Standard Approvals | UL 60950-1, CSA C22.2 No. 60950-1, TÜV EN 60950-1 |
| RoHS Compliant | Yes |
The power supply operates at an input voltage range of 90-264 VAC, with an input frequency of 47-63 Hz. It has an input current of 4.7 A (rms) for 115 VAC and 2.3 A (rms) for 230 VAC. The earth leakage current is a maximum of 300 μA at 264 VAC, 63 Hz.
The output voltage and current ratings vary depending on the model, with ripple and noise at 1% peak to peak maximum. Overvoltage protection is provided on output #1 only, set at 115-140% of its nominal output voltage. All outputs are protected against short circuit conditions, and the temperature coefficient for all outputs is ±0.04%/℃ maximum.
The operating temperature range is from 0 to +70℃, and the storage temperature range is from -40 to +85℃. It can operate in relative humidity from 5% to 95% non-condensing. There is a derating from 100% at +50℃ linearly to 50% at +70℃. Cooling is achieved with 35 CFM forced air or convection.
The power supply complies with UL 60950-1, CSA C22.2 No. 60950-1, and TÜV EN 60950-1 safety standards.
The power supply meets EN55022 Class B conducted and radiated emissions, EN61000-3-2 for harmonic distortion, Class A and D, and various EN61000-4 standards for immunity to ESD, radiated immunity, fast transient/burst, surge, conducted immunity, magnetic field immunity, and voltage dip.
The efficiency is a minimum of 70% on all models, and the typical power factor is 0.98.
The hold-up time is 12 ms minimum at 110 VAC.
The Mean Time Between Failures (MTBF) is calculated at 300,000 hours minimum at full load at 25℃ ambient, per MIL-HDBK-217F.
Yes, the power supply includes a Power Fail Detect (PFD) signal that provides a TTL logic high for normal operation and TTL logic low upon loss of input power. There is also a remote sense on output #1 and #2, and a remote inhibit feature that requires a TTL high signal to disable the output.
The power supply can be cooled either by 35 CFM forced air provided by the user or by convection cooling.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.