steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LC1D09B7 |
| Manufacturer | Schneider Electric |
| Product Type | Contactor |
| Utilisation Category | AC-1, AC-3, AC-3e, AC-4 |
| Poles Description | 3P (3 NO) |
| Rated Operational Voltage | Power circuit: <= 690 V AC 25...400 Hz, Power circuit: <= 300 V DC |
| Rated Operational Current | 9 A (<= 440 V AC AC-3), 25 A (<= 440 V AC AC-1) |
| Control Circuit Voltage | 24 V AC 50/60 Hz |
| Motor Power kW | Up to 5.5 kW at 500 V AC 50/60 Hz (AC-3), Up to 2.2 kW at 400 V AC 50/60 Hz (AC-4) |
| Horse Power Rating | Up to 7.5 Hp at 575/600 V AC 50/60 Hz for 3 phase motors |
| Rated Breaking Capacity | 250 A at 440 V for power circuit conforming to IEC 60947 |
| Rated Short-Time Withstand Current | 105 A at 40°C for 10 s for power circuit |
| Average Impedance | 2.5 mOhm at Ith 25 A 50 Hz for power circuit |
| Power Dissipation per Pole | 1.56 W AC-1, 0.2 W AC-3 |
| Rated Insulation Voltage | Power circuit: 690 V conforming to IEC 60947-4-1 |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947 |
| Mechanical Durability | 15 Mcycles |
| Electrical Durability | 0.6 Mcycles at 25 A AC-1, 2 Mcycles at 9 A AC-3 |
| Operating Rate | Maximum 3600 cyc/h at 60°C |
| Connections - Terminals | Screw clamp terminals for power and control circuits |
| Tightening Torque | 1.7 N.m for power and control circuit terminals |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| IP Degree of Protection | IP20 front face conforming to IEC 60529 |
| Protective Treatment | TH conforming to IEC 60068-2-30 |
| Climatic Withstand | Exposure to damp heat conforming to IEC 60947-1 Annex Q category D |
| Permissible Ambient Air Temperature | -40…60°C, 60…70°C with derating |
| Operating Altitude | 0...3000 m |
| Fire Resistance | 850°C conforming to IEC 60695-2-1 |
| Flame Retardance | V1 conforming to UL 94 |
| Mechanical Robustness | Vibrations: contactor open (2 Gn, 5...300 Hz), contactor closed (4 Gn, 5...300 Hz) |
| Height | 77 mm |
| Width | 45 mm |
| Depth | 86 mm |
| Net Weight | 0.32 kg |
The contactor is suitable for a variety of utilisation categories including AC-1, AC-3, AC-3e, and AC-4, making it versatile for resistive loads and motor control applications.
Yes, this contactor is designed for motor control applications and can handle various motor power ratings depending on the voltage and phase of the motor.
The rated operational current for the contactor in an AC-3 power circuit is 9A at less than 60°C, and 25A in an AC-1 power circuit at the same temperature range.
The contactor has a height of 77mm, a width of 45mm, and a depth of 86mm, making it compact for its capabilities.
The contactor is equipped with a 24V AC 50/60Hz coil, which is standard for this type of device.
The contactor has an IP20 degree of protection for the front face, conforming to IEC 60529 standards.
The contactor can operate in ambient air temperatures ranging from -40 to 60°C without derating, and up to 70°C with derating. It also has a fire resistance of 850°C conforming to IEC 60695-2-1.
The contactor is certified by multiple international standards, including CSA, EN, IEC, UL, and others, ensuring its compliance with global industry regulations.
The tightening torque for the power circuit screw clamp terminals is 1.7 N.m, ensuring a secure and reliable connection.
Yes, the contactor includes 1 normally open (NO) and 1 normally closed (NC) auxiliary contact, which are mechanically linked and conform to IEC standards.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.