steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LADR2 |
| Manufacturer | Schneider |
| Part Category | Auxiliary Contact |
| Rated Operational Voltage | 690 V AC, 25-400 Hz |
| Rated Insulation Voltage | 690 V conforming to IEC 60947-5-1, 600 V conforming to UL 60947-5-1, 600 V conforming to CSA C22.2 No 60947-5-1 |
| Rated Operational Current | 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, 0.1 A at 600 V DC-13 |
| Conventional Free Air Thermal Current | 10 A (at 60 °C) |
| Contact Composition | 1 Normally Open (NO) + 1 Normally Closed (NC) |
| Timer Type | Off delay |
| Time Delay Range | 1 to 30 seconds |
| Mounting Location | Front |
| Connections - Terminals | Screw clamp terminals for 1 to 2.5 mm² cables, flexible with or without cable end, rigid |
| Tightening Torque | 1.7 N.m with screwdriver flat Ø 6 mm, Philips No 2, or pozidriv No 2 |
| Mechanical Durability | 5 million cycles |
| Minimum Switching Current | 5 mA |
| Minimum Switching Voltage | 17 V |
| Non-overlap Time | 1.5 ms on de-energisation and energisation, no overlap between NC and NO contact |
| Insulation Resistance | > 10 MOhm |
| IP Degree of Protection | IP20 conforming to IEC 60529 |
| Protective Treatment | TH conforming to IEC 60068 |
| Ambient Air Temperature for Storage | -60 to 80 °C |
| Ambient Air Temperature for Operation | -40 to 70 °C |
| Operating Altitude | Up to 3000 m |
| Sustainable Offer Status | Green Premium product |
| Environmental Compliance | Compliant with EU RoHS Directive, Mercury free, PVC free |
| Dimensions (H x W x D) | 48 mm x 44 mm x 61 mm |
| Colour | Dark grey |
| Country of Origin | France |
The Schneider LADR2 is a versatile auxiliary contact block designed for use in a variety of industrial applications. It features a robust construction with a time delay range of 1 to 30 seconds, making it ideal for applications requiring precise timing control. The LADR2 is compatible with the TeSys Deca range and offers reliable performance with a high mechanical durability of 5 million cycles. Its compact design and front mounting location allow for easy integration into existing systems. With compliance to international standards and environmental regulations, the LADR2 is a sustainable choice for modern automation needs.
The Schneider auxiliary contact block is designed to provide time delay functionality in electrical circuits, specifically for use with TeSys Deca contactors.
The rated operational voltage for this auxiliary contact block is 690 V AC, suitable for frequencies between 25 and 400 Hz.
The time delay range for this auxiliary contact block is adjustable from 1 to 30 seconds.
This auxiliary contact block features a 1 NO (normally open) and 1 NC (normally closed) contact configuration.
The rated insulation voltage for this auxiliary contact block is 690 V, conforming to IEC 60947-5-1 standards.
The mechanical durability of this auxiliary contact block is rated at 5 million cycles.
This auxiliary contact block has an IP20 degree of protection, conforming to IEC 60529 standards.
This auxiliary contact block can operate in ambient temperatures ranging from -40°C to 70°C and at altitudes up to 3000 meters.
The rated making capacity is 140 A at up to 690 V AC, conforming to IEC 60947-5-1 standards.
This auxiliary contact block uses screw clamp terminals, suitable for cables ranging from 1 to 2.5 mm².
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
You don’t need tights and a cape to be a hero.
Get parts fast and feel like a legend, just like Jeff.