steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | CA3KN31MD3 |
| Manufacturer | Schneider |
| Range | TeSys |
| Product Name | TeSys CAK |
| Product Type | Control relay |
| Device Short Name | CA3K |
| Contactor Application | Control circuit |
| Utilisation Category | AC-15, DC-13 |
| Pole Contact Composition | 3 NO + 1 NC |
| Rated Operational Voltage [Ue] | <= 690 V, <= 400 Hz |
| Control Circuit Type | DC standard |
| Control Circuit Voltage [Uc] | 220 V DC |
| Coil Technology | Built-in bidirectional peak limiting diode suppressor |
| Conventional Free Air Thermal Current [Ith] | 10 A (at 50 °C) |
| Rated Making Capacity [Irms] | 110 A conforming to IEC 60947 |
| Associated Fuse Rating | 10 A gG conforming to IEC 60947, 10 A gG conforming to VDE 0660 |
| Rated Insulation Voltage [Ui] | 690 V conforming to IEC 60947, 750 V conforming to VDE 0110 group C, 690 V conforming to BS 5424, 600 V conforming to CSA C22.2 No 14 |
| Mounting Support | Rail, Plate |
| Connections - Terminals | Screw clamp terminals for various cable types and sizes |
| Tightening Torque | 1.3 N.m with screwdriver (flat Ø 6 mm, Philips No 2, pozidriv No 2) |
| Control Circuit Voltage Limits | Operational: 0.8...1.15 Uc (at <50 °C), Drop-out: 0.1...0.75 Uc (at <50 °C) |
| Operating Time | 10 ms coil de-energisation and NO opening, 30...40 ms coil energisation and NO closing, 15 ms coil de-energisation and NC closing, 25...35 ms coil energisation and NC opening |
| Mechanical Durability | 20 Mcycles |
| Maximum Operating Rate | 10000 cyc/h |
| Immunity to Microbreaks | 2 ms |
| Inrush Power | 3 W (at 20 °C) |
| Hold-in Power Consumption | 3 W at 20 °C |
| Heat Dissipation | 3 W |
| Minimum Switching Voltage | 17 V |
| Minimum Switching Current | 5 mA |
| Non Overlap Distance | 0.5 mm |
| Insulation Resistance | > 10 MOhm |
| Height | 58 mm |
| Width | 45 mm |
| Depth | 57 mm |
| Net Weight | 0.225 kg |
| Standards | BS 5424, IEC 60947, NF C 63-140, VDE 0660 |
| Product Certifications | CSA, UL |
| IP Degree of Protection | IP2X |
| Protective Treatment | TC conforming to IEC 60068 |
| Ambient Air Temperature for Operation | -25…50 °C |
| Ambient Air Temperature for Storage | -50…80 °C |
| Operating Altitude | 2000 m without derating |
| Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102 |
| Mechanical Robustness | Vibrations: contactor open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6, Vibrations: contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6, Shocks: contactor open: 10 Gn for 11 ms conforming to IEC 60068-2-27, Shocks: contactor closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 |
| Sustainable Offer Status | Green Premium product |
| REACh Regulation | REACh Declaration, REACh free of SVHC |
| EU RoHS Directive | Compliant, EU RoHS Declaration |
| Toxic Heavy Metal Free | Yes |
| Mercury Free | Yes |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile, Circularity Profile, End Of Life Information |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
The primary function of this control relay is to manage control circuits, making it suitable for various industrial applications.
This relay features a contact configuration of 3 normally open (NO) and 1 normally closed (NC) contacts.
The rated operational voltage for this relay is up to 690 V at 400 Hz.
This relay uses a DC standard control circuit voltage of 220 V DC.
The conventional free air thermal current rating for this relay is 10 A at 50°C.
The dimensions of this relay are 58 mm in height, 45 mm in width, and 57 mm in depth.
This relay has a mechanical durability of 20 million cycles.
The maximum operating rate for this relay is 10,000 cycles per hour.
This relay can be mounted on both rail and plate supports.
This relay operates within an ambient air temperature range of -25°C to 50°C and can be stored at temperatures between -50°C and 80°C.
The IP degree of protection for this relay is IP2X.
This relay is certified by CSA, UL, and conforms to standards such as IEC 60947 and VDE 0660.
The rated insulation voltage for this relay is 690 V according to IEC 60947 and 750 V according to VDE 0110 group C.
The inrush power consumption of this relay is 3 W at 20°C.
The minimum switching voltage is 17 V and the minimum switching current is 5 mA.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.